HomeMy WebLinkAboutFargo Consultants, Inc. - 4/18/2017F74- 2324 Fabens Rd. - Dallas Texas 7522: wnxc�n corrvur:rnwrs, Tyre. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Pagel of Tested For: JLB Partners, LP Date Performed: 4/18/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(Vo) Max. DD (pcj) DD Range (%) MC Range 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 2061 SG BLDG. PAD 3 GRID POINT K.1-52.7 (S. SITE GRID) 3 95.9 25.2 93 2062 SG BLDG. PAD 3 GRID POINT M 6-52.5 (S. SITE GRID) 4 92.8 26.8 95.9 2063 1ST BLDG. PAD 3 GRID POINT K.4-52.1 (S. SITE GRID) 4 90.6 26.6 93.6 2064 2ND BLDG. PAD 3 GRID POINT K,6-52.6 (S. SITE GRID) 4 90.1 26.4 93.1 2065 1ST BLDG. PAD 3 GRID POINT M.1-52.5 (S. SITE GRID) 4 92.3 26.7 95.4 2066 2ND BLDG. PAD 3 GRID POINT M.6-52.7 (S. SITE GRID) 3 95.9 25.2 93 2067 3RD BLDG, PAD 3 GRID POINT K.7-52.6 (S. SITE GRID) 4 91.8 26.7 94.8 2068 4TH BLDG. PAD 3 GRID POINT K.6-52.2 (S. SITE GRID) 3 96.1 25.1 93.2 2069 3RD BLDG. PAD 3 GRID POINT M_5-52.7 (S. SITE GRID) 4 92.4 27 955 2070 4TH BLDG. PAD 3 GRID POINT M.3-52.9 (S. SITE GRID) 3 97.3 24.8 944 2071 5TH BLDG. PAD 3 GRID POINT K.1-52.7 (S. SITE GRID) 3 96.2 24.1 93.3 2072 6TH BLDG. PAD 3 GRID POINT K-52.2 (S. SITE GRID) 4 91.3 27.3 94.3 2073 5TH BLDG. PAD 3 GRID POINT M.6-52.6 (S. SITE GRID) 3 97.1 23.6 94.2 2074 6TH BLDG. PAD 3 GRID POINT M.7-52.4 (S. SITE GRID) 4 91,7 26.8 94.7 2075 3RD BLDG. PAD 6 GRID POINT H.4-39.6 (N. SITE GRID) 4 90.9 27.5 93,9 2076 4TH BLDG. PAD 6 GRID POINT H.5-39.7 (N. SITE GRID) 3 97.2 25.1 94.3 2077 3RD BLDG. PAD 6 GRID POINT H.6-40.6 (N. SITE GRID) 4 90.3 27.2 93.3 2078 4TH BLDG. PAD 6 GRID POINT H_1-40.1 (N. SITE GRID) 3 97.6 24.9 94.7 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dalla,rfarfo.com �0 2324 Fabens Rd. • Dallas, "Texas 75225 iAkR .o CONS U rJ ANr6, rNO. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 4/18/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (pcfi Moisture Density 2079 5TH BLDG. PAD 6 GRID POINT H.6-39.7 (N. SITE GRID) 4 92.9 26.6 96 2080 6TH BLDG. PAD 6 GRID POINT H.1-39.6 (N. SITE GRID) 4 91.8 26.7 94.8 2081 5TH BLDG. PAD 6 GRID POINT H.7-40.4 (N. SITE GRID) 3 96.1 25.3 93.2 2082 6TH BLDG. PAD 6 GRID POINT H.6-40.1 (N. SITE GRID) 4 91.3 26.8 94.3 2083 7TH BLDG_ PAD 6 GRID POINT H2-39.6 (N. SITE GRID) 4 91.8 26.6 94.8 2084 8TH BLDG. PAD 6 GRID POINT H.5-39 (N. SITE GRID) 4 92.3 26.9 95.4 2085 7TH BLDG. PAD 6 GRID POINT H.1-40.7 (N. SITE GRID) 4 92.8 27.3 95.9 2086 8TH BLDG. PAD 6 GRID POINT H.6-40.6 (N. SITE GRID) 4 90.6 27.4 93.6 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo.consultants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Gary Moore, CET 'Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval, Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,go.com