Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 4/19/2017 (4)gn7ec+o cnrrsvxanmres, zxr�. 2324 Fabens Rd. - Dallas, Texas 75225 "Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 1 Tested For: JLB Partners, LP Date Performed: 4/19/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(01o) Max DD (pcfi DD Range (%) MC Range 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. ILift Location No (pcfi Moisture Density 2087 7TH BLDG. PAD 3 GRID POINT K.5-52.1 (S. SITE GRID) 3 99.9 24.8 96.9 2088 7TH BLDG. PAD 3 GRID POINT M.3-52.6 (S. SITE GRID) 3 100.6 23.8 97.6 2089 8TH BLDG. PAD 3 GRID POINT K.4-52.4 (S. SITE GRID) 3 100.9 24.1 97.9 2090 8TH BLDG. PAD 3 GRID POINT M.3-52.2 (S. SITE GRID) 3 100 23.4 97 2091 9TH BLDG, PAD 6 GRID POINT H.1-39.6 (N. SITE GRID) 4 94.8 27 97.9 2092 9TH BLDG. PAD 6 GRID POINT H.5-40.2 (N. SITE GRID) 4 92.1 28.2 95.1 2093 10TH BLDG. PAD 6 GRID POINT H.6-39 (N. SITE GRID) 4 93.3 28.9 96.4 2094 10TH BLDG. PAD 6 GRID POINT H.1-40.7 (N. SITE GRID) 4 94 26.7 97.1 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, a i !tants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate.lC 4iVale oore, CET ls Testing Division l The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallai-farffo.com