HomeMy WebLinkAboutFargo Consultants, Inc. - 4/28/2017F.`;700 2324 Fabens Rd. • Dallas 7Texas 7522: :- pnrcceo naNf,us.Tarres, sten. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I of 2 Tested For: JLB Partners, LP Date Performed: 4/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(Yo) Max DD (pci DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 2215 3RD BLDG. PAD 3 GRID POINT S-52 (S. SITE GRID) 3 97.9 23.8 95 2216 4TH BLDG. PAD 3 GRID POINT S-52 IS. SITE GRID) 3 97.1 23.5 94.2 2217 5TH BLDG, PAD 3 GRID POINT S-52 IS. SITE GRID) 3 98.4 23.7 95.4 2218 6TH BLDG. PAD 3 GRID POINT S.4-52 (S. SITE GRID) 3 98 23.3 95.1 2219 7TH BLDG. PAD 3 GRID POINT S.1-52.8 (S. SITE GRID) 3 96.3 24.5 93.4 2220 8TH BLDG, PAD 3 GRID POINT S.6-52.6 (S. SITE GRID) 3 96.7 24.8 93.8 2221 9TH BLDG. PAD 3 GRID POINT S.3-52.1 (S. SITE GRID) 4 92.6 27.4 95.7 2222 10TH BLDG. PAD 3 GRID POINT S.7-52,6 (S. SITE GRID) 4 92.2 26.8 95.2 2223 11TH BLDG. PAD 3 GRID POINT S,1-52.4 (S. SITE GRID) 3 95.9 24.9 93 2224 12TH BLDG. PAD 3 GRID POINT S.6-52.8 (S. SITE GRID) 3 96.5 23.6 936 2225 13TH BLDG. PAD 3 GRID POINT S.2-52.2 (S. SITE GRID) 1 99.4 23.2 94.2 2226 6TH BLDG. PAD 5 GRID POINT F.4-44 (N. SITE GRID) 3 96.6 23.8 93.7 2227 7TH BLDG. PAD 5 GRID POINT F.8-44.7 (N. SITE GRID) 3 96.9 23.5 94 2228 8TH BLDG. PAD 5 GRID POINT F,1-44.3 (N. SITE GRID) 3 98.1 24.2 95.2 2229 9TH BLDG. PAD 5 GRID POINT F.5-44.1 (N. SITE GRID) 1 98.7 23.4 93.6 2230 10TH BLDG. PAD 5 GRID POINT F.6-44.8 IN. SITE GRID) 1 99.5 22.9 94.3 2231 11TH BLDG. PAD 5 GRID POINT F.1-44.2 (N. SITE GRID) 3 95.9 25.2 93 2232 12TH BLDG. PAD 5 GRID POINT F.7-44.9 (N. SITE GRID) 3 96.3 24.9 93.4 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com ■ ■�_ 0 2324 Fabens Rd. • Dallas, Texas 7522: FIiGa uaAnxvsUM- Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 4/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pcf) Moisture Density 2233 13TH BLDG. PAD 5 GRID POINT F.5-44.7 (N_ SITE GRID) 1 98.8 22.9 93.6 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo 71sult nis, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. �p�� Test locations are referenced using an in-house system and are approximate. w=f Moore, CET rials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,eo.com