Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 5/11/2017 (2)• ■ • IGO 2324 Pabens Rd. • llallas, 'Texas 75225 FARCO CONSULTANTS, INC, Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 5/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent Location No. /Lift No (pcf) Moisture Density 2306 9TH BLDG PAD 4 GRID POINT E.5-49.4 (N. SITE GRID) 3 96.2 24.8 93.3 2307 10TH BLDG. PAD 4 GRID POINT E.5-49.6 (N. SITE GRID) 3 96.7 24.2 93.8 2308 9TH BLDG. PAD 4 GRID POINT F.5-48.5 (N. SITE GRID) 1 99.5 23.4 94.3 2309 10TH BLDG. PAD 4 GRID POINT F.5-48.4 (N. SITE GRID) 3 97.3 23.9 944 2310 11TH BLDG. PAD 4 GRID POINT E.5-49.1 (N. SITE GRID) 3 96.8 24.1 93.9 2311 12TH BLDG. PAD 4 GRID POINT E.5-49 (N. SITE GRID) 3 97.2 24.4 94.3 2312 13TH BLDG. PAD 4 GRID POINT E.5-49.6 (N SITE GRID) 1 100.4 23.3 95.2 2313 11TH BLDG. PAD 4 GRID POINT F.5-48.7 (N. SITE GRID) 3 97,7 24.3 94.8 2314 12TH BLDG_ PAD 4 GRID POINT F.5-48.4 (N. SITE GRID) 1 100.2 22.9 95 2315 13TH BLDG, PAD 4 GRID POINT F.5-48.5 (N. SITE GRID) 1 99.8 23.1 94.6 2316 SG BLDG. PAD 4 GRID POINT Y.5-53,1 (S. SITE GRID) 3 97.4 24.2 94.5 2317 SG BLDG. PAD 4 GRID POINT X.5-53.7 (S. SITE GRID) 1 98.9 23.6 93.7 2318 IST BLDG, PAD 4 GRID POINT Y.5-53.6 (S. SITE GRID) 3 97,9 23.5 95 2319 2ND BLDG. PAD 4 GRID POINT Y.7-53,1 (S. SITE GRID) 1 98.8 24 93.6 2320 1ST BLDG_ PAD 4 GRID POINT X.5-53.3 (S. SITE GRID) 1 99.9 23.3 94.7 2321 2ND BLDG. PAD 4 GRID POINT X.5-53,7 (S. SITE GRID) 3 97.3 23.7 94.4 2322 3RD BLDG. PAD 4 GRID POINT Y.4-53 (S. SITE GRID) 3 96.8 24.5 93.9 2323 4TH BLDG. PAD 4 GRID POINT Y.5-53.1 (S. SITE GRID) 1 98.3 23.7 93.2 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Services www.dallasfarfo.com F.1-700 2324 Fabens Rd. - Dallas, Texas 75225 )FArzaa CONFVr.TANT9, rNQ. Tel. 214-352-4100 Fax. 214-352-4811 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo C" nsult its, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. G Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Contraction Materials Testing • Environmental Semices w)vw. dallasfarQo. com REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 5/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (pcfi Moisture Density 2324 3RD BLDG. PAD 4 GRID POINT X9-53.7 (S. SITE GRID) 3 96.5 24.8 93.6 2325 4TH BLDG, PAD 4 GRID POINT X.4-53 (S. SITE GRID) 1 98.7 23.5 93.6 2326 5TH BLDG. PAD 4 GRID POINT Y.5-53,6 (S. SITE GRID) 3 95.9 25.3 93 2327 6TH BLDG. PAD 4 GRID POINT Y.3-53.1 (S, SITE GRID) 3 97.2 24.4 94.3 2328 5TH BLDG. PAD 4 GRID POINT X5-53.9 (S. SITE GRID) 3 96.1 25 93.2 2329 6TH BLDG. PAD 4 GRID POINT X.1-53.4 (S. SITE GRID) 3 96.4 24.8 93.5 2330 7TH BLDG. PAD 4 GRID POINT Y,6-53.6 (S. SITE GRID) 3 98.3 24.4 95.3 2331 8TH BLDG. PAD 4 GRID POINT Y.5-53.4 (S_ SITE GRID) 3 97,8 24.1 94.9 2332 7TH BLDG. PAD 4 GRID POINT X7-53.9 (S. SITE GRID) 1 99.6 23 94.4 2333 8TH BLDG. PAD 4 GRID POINT X,2-53.2 (S. SITE GRID) 3 98.1 23.7 95.2 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo C" nsult its, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. G Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Contraction Materials Testing • Environmental Semices w)vw. dallasfarQo. com