HomeMy WebLinkAboutFargo Consultants, Inc. - 5/15/20172324 Fabens Rd. • Dallas, '1'cxas 7522; f'AVR00 CON V. U r.TAA TS. INI C. 'Fel. 214-352-4100 Fax. 214-352-4817 REPORT OF FIELD COMPACTION Page 1 of Tested For: JLB Partners, LP Date Performed: 5/15/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent Location No. /Lift No (pct Moisture Density 2346 1ST BLDG. PAD 4 GRID POINT X.4-52.6 (S. SITE GRID) 3 96.7 23.8 93.8 2347 2ND BLDG. PAD 4 GRID POINT X_6-52.1 (S. SITE GRID) 3 96.3 24.2 93.4 2348 1ST BLDG. PAD 4 GRID POINT X.1-53.6 (S. SITE GRID) 3 97.4 23.3 94.5 2349 2ND BLDG. PAD 4 GRID POINT X-53.7 (S. SITE GRID) 1 98.6 23.5 93.5 2350 3RD BLDG, PAD 4 GRID POINT X6-52.1 (S. SITE GRID) 3 96.1 24.9 93.2 2351 4TH BLDG. PAD 4 GRID POINT X1-52.7 (S. SITE GRID) 4 92.9 26.4 96 2352 3RD BLDG. PAD 4 GRID POINT X.4-53.6 IS. SITE GRID) 3 95,9 25.3 93 2353 4TH BLDG_ PAD 4 GRID POINT X.3-53.4 (S. SITE GRID) 3 97 23.3 94.1 2354 5TH BLDG. PAD 4 GRID POINT X.7-52.2 (S. SITE GRID) 3 96.8 23.9 93.9 2355 6TH BLDG. PAD 4 GRID POINT X 3-52.6 (S. SITE GRID) 3 97.6 25.1 94.7 2356 5TH BLDG. PAD 4 GRID POINT X.4-53 (S, SITE GRID) 3 97.8 23.6 94.9 2357 6TH BLDG. PAD 4 GRID POINT X.6-53.7 (S. SITE GRID) 3 96.2 24.8 93.3 2358 7TH BLDG. PAD 4 GRID POINT X.1-52.1 (S. SITE GRID) 3 97 24.1 94.1 2359 8TH BLDG. PAD 4 GRID POINT X.6-52.5 (S_ SITE GRID) 3 96.9 25.3 94 2360 7TH BLDG. PAD 4 GRID POINT X.1-53.7 IS. SITE GRID) 3 95.9 24.8 93 2361 8TH BLDG. PAD 4 GRID POINT X.6-53.6 (S. SITE GRID) 4 92.7 26.4 95.8 2362 9TH BLDG. PAD 4 GRID POINT X.7-52.1 (S. SITE GRID) 3 97.9 23.9 95 2363 10TH BLDG. PAD 4 GRID POINT X.1-52.4 (S. SITE GRID) 3 97.1 24.9 94.2 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our offices Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and Lest results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Constrnrction Alatorials Tasting • Environmental Services www.dallasfarfo.com C'-%gJLMP�J 2324 Fabens Rd. - Dallas, Texas 75225 vAnon CONSULTANTS, rNa'. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 5/15/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pcJ) Moisture Density 2364 9TH BLDG. PAD 4 GRID POINT X.1-53.6 (S. SITE GRID) 4 94 26.6 97.1 2365 10TH BLDG PAD 4 GRID POINT X.6-53.7 (S. SITE GRID) 3 97.7 24.2 94.8 2366 11TH BLDG, PAD 4 GRID POINT X,4-52.4 (S. SITE GRID) 3 97,2 23.5 94.3 2367 12TH BLDG. PAD 4 GRID POINT X.3-52.7 (S. SITE GRID) 3 96.7 23.8 93.8 2368 13TH BLDG. PAD 4 GRID POINT X.7-52.6 (S. SITE GRID) 1 98.5 23.6 93.4 2369 11 TH BLDG. PAD 4 GRID POINT X.3-53.7 (S. SITE GRID) 3 97.6 24.3 94.7 2370 12TH BLDG. PAD 4 GRID POINT X.1-53.6 (S SITE GRID) 1 98.9 24.1 93.7 2371 13TH BLDG. PAD 4 GRID POINT X-53.4 (S. SITE GRID) 1 99.6 22.9 94.4 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo C nsult nts, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. G Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety_ Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com