Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/4/2017FArLGO CON SUL.TANTS, INC, 2324 Fabcns Rd. • Dallas,'1'c�as 75225 'Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 3/4/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-50OIEZ Probe Depth: 8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Servicer www.dallasfarfo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max. DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 1253 13TH BLDG. PAD 17 GRID POINT Q.4-9.4 (S SITE GRID) 1 99.7 22.9 94.5 1254 13TH BLDG. PAD 17 GRID POINT Q.6-8.5 (S. SITE GRID) 1 99.1 23.3 93.9 1255 SG BLDG. PAD 17 GRID POINT S-8.3 (S. SITE GRID) 3 95.9 24.9 93 1256 SG BLDG. PAD 17 GRID POINT S.7-9.7 (S. SITE GRID) 3 96 242 93.1 1257 1ST BLDG. PAD 17 GRID POINT S.4-8.6 (S. SITE GRID) 1 98.5 23.1 93.4 1258 2ND BLDG. PAD 17 GRID POINT S.9-8.1 (S. SITE GRID) 3 96.6 235 93.7 1259 1ST BLDG. PAD 17 GRID POINT S.1-9.6 (S. SITE GRID) 3 97.1 23.3 94.2 1260 5TH BLDG. PAD 11 GRID POINT Z.7-35.1 (N. SITE GRID) 5 103.4 20.8 97.5 1261 6TH BLDG. PAD 11 GRID POINT Z,6-35.6 (N. SITE GRID) 5 101.5 21.3 95.7 1262 5TH BLDG. PAD 11 GRID POINT Y.4-36.7 (N. SITE GRID) 5 102.6 21 96.7 1263 6TH BLDG. PAD 11 GRID POINT Y.6-36.4 (N. SITE GRID) 5 101 8 20.9 95.9 1264 7TH BLDG, PAD 11 GRID POINT Z.7-35.3 (N. SITE GRID) 5 100.5 21.4 94.7 1265 7TH BLDG. PAD 11 GRID POINT Y-36.1 (N. SITE GRID) 5 99.5 21.1 93.8 1266 2ND BLDG. PAD 17 GRID POINT S.1-9.6 (S. SITE GRID) 1 98.7 22.9 93.6 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Servicer www.dallasfarfo.com FARGO CONSULTANTS. INC, REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Fabens Rd. • Dallas 'Tcxvs 75225 Tel. 214-352-4100 Pax. 214-352-4811 Page 2 of 2 Date Performed: 3/4/2017 Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, 7-7 oils el i�Lr, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate.�`� G Moore, CET aterialTesting Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering •Con traction Materials Te ting • Environmental Servicer www. dallasfarpo. com