REPORT OF FIELD COMPACTION Page I of 1
Tested For: JLB Partners, LP Date Performed: 2/16/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Gra evine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS -5001 EZ
Probe Depth:8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max. DD (pefi DD Range(/,,) MC Range
1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4
3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 95 to 100 0 to +4
5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 95 to 100 0 to +4
Field Test Results
Test Elevation Proctor DryDensity Percent Percent
No. ILift Location No (p
c Moisture Density
55 FG FIRE LANE GRID POINT R-13 (SOUTH SITE GRID) 1 103.5 20.1 98.1
56 FG FIRE LANE GRID POINT S-17 (SOUTH SITE GRID) 1 105.1 19.2 99.6
57 FG FIRE LANE GRID POINT R-20 (SOUTH SITE GRID) 1 104.3 19.5 98.9
58 FG FIRE LANE GRID POINT P-22 (SOUTH SITE GRID) 3 101.5 20.5 98.4
59 FG FIRE LANE GRID POINT P-16 (SOUTH SITE GRID) 5 104.3 19.2 983
60 FG FIRE LANE GRID POINT 0-13 (SOUTH SITE GRID) 5 103.2 18.1 97.3
61 11TH WEST PARKING AREA GRID POINT 1-7 (NORTH SITE GRID) 1 102.2 22 96.9
62 11TH WEST PARKING AREA GRID POINT Z-7 (NORTH SITE GRID) 1 102.5 21.6 97.2
Source of Compaction Requirements: Geotechnical Report Respectfully Submitted,
Fargo tlsttlf is, Inc.
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Test locations are referenced using an in-house system and are approximate.
6'u Moore, CET
rrterials Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services