HomeMy WebLinkAboutFargo Consultants, Inc. - 5/23/20171"n ROO O'ONSUC.TAl4TS. INC.
2324 Fabens Rd. • Drillas Texas 75225
Tel. 214-352-4100 Fax. 214-352-4811
REPORT OF FIELD COMPACTION Page 1 of 1
Tested For: JLB Partners, LP Date Performed: 5/23/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max. DD (pcj) DD Range (%) MC Range
8 Reddish Brown and Tan CLAYEY SAND 13 115 Min. 95 -2 to +2
Field Test Results
Test
Elevation
Location
No.
ILift
113.8
211
FG
FIRE LANE GRID POINT 0-12 (S. SITE GRID)
212
FG
FIRE LANE GRID POINT V-12 (S. SITE GRID)
213
FG
PARKING LOT AREA GRID POINT Z-8 (S. SITE GRID)
214
FG
FIRE LANE GRID POINT 1C-12 (S. SITE GRID)
Source of Compaction Requirements: Geotechnical Report
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Test locations are referenced using an in-house system and are approximate.
Proctor DryDensity
No
(pcf)
8
114.9
8
113.8
8
109.5
8
110.3
Percent Percent
Moisture Density
13 99.9
14.4 99
14.8 95.2
14,1 95.9
Respectfully Submitted,
Fargo CpnsuffInts, Inc.
"'ems
Ga Moore, CET
aterlals Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing •Environmental Services
www. dallasfarpo. com