Fargo Consultants, Inc. - 6/27/2017 (3)
2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FARGO CJONS[I&7 B, II3C: FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Report Date: 6/27/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 6/26/2017 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3230 Calibration Date: 6/15/2017 Gauge No.: R-129 Pump No.: 337463 Location: Floor Slab Building 3 (Type I -I) POUR 1 Tolerance: ± 10% Required Minimum Maximum First Second Total Variation in Final Pressure Cable ID Strand Elongation Elongation Elongation Elongation Elongation Elongation % (pSI) Mark (Inch) (Inch) (Inch) (Inch) (Inch) (Inch) Elongation T97 26 1.88 1.69 2.07 2.0 2.0 6 5500 T98 26 1.88 1.69 2.07 2.0 2.0 6 5500 T99 26 1.88 1.69 2.07 2.0 2.0 6 5500 T100 26 1.88 1.69 2.07 2.0 2.0 6 5500 T101 35 2.63 2.37 2.89 2.6 2.6 -1 5500 T102 35 2.63 2.37 2.89 2.7 2.7 3 5500 T103 37 2.88 2.59 3.17 2.9 2.9 1 5500 T104 40 3.13 2.82 3.44 3.2 3.2 2 5500 T105 69 5.50 4.95 6.05 5.5 5.5 0 5500 T106 69 5.50 4.95 6.05 1 5.8 5.8 5 5500 T107 69 5.50 4.95 6.05 5.8 5.8 5 5500 T108 69 5.50 4.95 6.05 5.6 5.6 2 5500 T109 69 5.50 4.95 6.05 5.7 5.7 4 5500 T110 16 1.00 0.90 1.10 1.0 1.0 0 5500 T111 16 1.00 0.90 1 1.10 T112 20 1.38 1.24 1.52 1.4 1.4 1 5500 T113 68 5.38 4.84 5.92 5.5 5.5 2 5500 T114 68 5.38 4.84 5.92 5.8 5.8 8 5500 T115 63 5.00 4.50 5.50 5.3 5.3 6 5500 T116 63 5.00 4.50 5.50 5.4 5.4 8 5500 T117 63 5.00 4.50 5.50 5.3 5.3 6 5500 T118 69 5.50 4.95 6.05 5.5 5.5 0 5500 T119 69 5.50 4.95 6.05 5.8 5.8 5 5500 T120 69 5.50 4.95 6.05 5.5 5.5 0 5500 T121 69 5.50 4.95 6.05 5.6 5.6 2 5500 T122 69 5.50 4.95 6.05 5.5 5.5 0 5500 7T123 71 5.63 5.07 6.19 5.9 5.9 5 5500 Page 1 of 4 www.dallasfargo.com Checked - '�K� By: ■ ,-_AR014 [ 0N,-;7MT-ANTS, INC; 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3230 Gauge No.: R-129 Location: Floor Slab Building 3 (Type I -I) POUR 1 Report Date: 6/27/2017 Stressed Date: 6/26/2017 Project No: M16-4962 Calibration Date: 6/15/2017 Pump No.: 337463 Tolerance: ± 10 Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T124 71 5.63 5.07 6.19 5.9 5.9 5 5500 T125 69 5.50 4.95 6.05 5.8 5.8 5 5500 T126 69 5.50 4.95 6.05 5.9 5.9 7 5500 T127 69 5.50 4.95 6.05 5.8 5.8 5 5500 T128 70 5.50 4.95 6.05 5.9 5.9 7 5500 T129 25 1.88 1.69 2.07 2.0 2.0 6 5500 T130 1 25 1.88 1.69 2.07 1.8 1.8 -4 5500 T131 25 1.88 1.69 2.07 1.8 1.8 -4 5500 T132 70 5.50 4.95 6.05 5.9 5.9 7 5500 T133 70 5.50 4.95 6.05 5.9 5.9 7 5500 T134 58 4.63 4.17 5.09 4.6 4.6 -1 5500 T135 58 4.63 4.17 5.09 4.5 4.5 -3 5500 T136 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T137 71 5.63 5.07 6.19 5.8 5.8 3 5500 T138 68 5.38 4.84 5.92 5.6 5.6 4 5500 T139 68 5.38 4.84 5.92 5.5 5.5 2 5500 T140 68 5.38 4.84 5.92 5.5 5.5 2 5500 T141 68 5.38 4.84 5.92 5.5 5.5 2 5500 T142 68 5.38 4.84 5.92 5.4 5.4 0 5500 T143 74 6.00 5.40 6.60 6.0 6.0 0 5500 T144 74 6.00 5.40 6.60 6.0 6.0 0 5500 T145 71 5.63 5.07 6.19 5.8 5.8 3 5500 T146 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T147 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T148 71 5.63 5.07 1 6.19 5.8 5.8 3 5500 T149 1 71 5.63 5.07 6.19 5.8 5.8 3 5500 T150 1 14 0.88 0.79 0.96 0.9 0.9 3 1 5500 Page 2 of 4 www.dallasfargo.com Checked 8y: A.RGO CONSULTANTS, INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3230 Gauge No.: R-129 Location: Floor Slab Building 3 (Type I -I) POUR 1 Report Date: 6/27/2017 Stressed Date: 6/26/2017 Project No: Ml 6-4962 Calibration Date: 6/15/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation Inch (Inch) Minimum Elongation Inch (Inch) Maximum Elongation Inch (Inch) First Elongation Inch (Inch) Second Elongation (Inch) Inch Total Elongation Inch (Inch) Variation in % Elongation g Final Pressure (PSI) T151 14 0.88 0.79 0.96 0.9 0.9 3 5500 T152 1 30 2.25 2.03 2.48 2.3 2.3 1 2 5500 T153 30 2.25 2.03 2.48 2.3 2.3 2 5500 T154 30 2.25 2.03 2.48 2.3 2.3 2 5500 T155 30 2.25 2.03 1 2.48 2.4 2.4 7 5500 T156 1 109 8.75 7.88 9.63 9.0 9.0 3 5500 T157 109 8.75 7.88 9.63 9.3 9.3 6 5500 T158 109 8.75 7.88 9.63 9.0 9.0 3 5500 T159 109 8.75 7.88 1 9.63 9.2 9.2 5 5500 T160 109 8.75 7.88 9.63 9.0 9.0 3 5500 T161 111 8.88 7.99 9.77 9.0 9.0 1 5500 T162 111 8.88 7.99 9.77 1 8.9 8.9 0 5500 T163 111 8.88 7.99 9.77 9.2 9.2 4 5500 T164 111 8.88 7.99 9.77 9.2 9.2 4 5500 T165 111 8.88 7.99 9.77 9.0 9.0 1 5500 T166 111 8.88 7.99 9.77 9.0 9.0 1 5500 T167 111 8.80 7.92 9.68 8.8 8.8 0 5500 T168 101 8.13 7.32 8.94 8.3 8.3 1 2 5500 T169 101 8.13 7.32 8.94 1 8.0 8.0 -2 5500 T170 101 8.13 7.32 8.94 8.2 8.2 1 5500 T171 101 8.13 7.32 8.94 8.2 8.2 1 5500 T172 1 101 8.13 7.32 8.94 8.0 8.0 -2 5500 T173 90 7.13 6.42 7.84 1 7.5 7.5 5 5500 T174 90 7.13 6.42 7.84 7.4 7.4 4 5500 T175 90 7.13 6.42 7.84 7.4 7.4 4 5500 T176 90 7.13 6.42 7.84 7.5 7.5 5 5500 T177 90 7.13 1 6.42 7.84 1 7.3 7.3 1 2 5500 Page 3 of 4 www.dallasfargo.com Checked By: 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3230 Gauge No.: R-129 Location: Floor Slab Building 3 (Type I-1) POUR 1 Report Date: 6/27/2017 Stressed Date: 6/26/2017 Project No: M16-4962 Calibration Date: 6/15/2017 Pump No.: 337463 Tolerance: ± 10 Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation Inch) Second Elongation (Inch) Total Elongation Inch) Variation in % Elongation Final Pressure (PSI) T178 90 7.13 6.42 7.84 7.2 7.2 1 5500 T179 90 7.13 6.42 1 7.84 7.2 7.2 1 5500 T180 90 7.13 6.42 7.84 7.0 7.0 -2 5500 T181 90 7.13 6.42 7.84 7.2 7.2 1 5500 T182 90 7.13 6.42 7.84 7.0 7.0 -2 5500 T183 30 2.25 2.03 2.48 2.3 2.3 2 5500 T184 30 2.25 2.03 2.48 2.3 2.3 2 5500 T185 51 4.00 3.60 4.40 4.0 4.0 0 5500 T186 51 4.00 3.60 4.40 4.1 4.1 1 2 5500 * Repair Required. Page 4 of 4 www.dallasfargo.com y Checked B: CCi Ready Cable ine. 4416 Keller Hicks Rd., Fort Worth, TX 76244 817.379.6553 Main 817.379.4007 Fax REPORT: EMILIO PUMP S/N: 337463 RAM S/N: PSL -3230 GAUGE: R-129 DATE: CALIBRATION STANDARD: P-3500 STRAIN INDICATOR LOAD CELL 50 KIPS 6/15/2017 0148342 070202 Gauge Pressure (PSI) Load Cell Readings Average of Three Readings #1 #2 #3 1,000 6,360 6,500 6,660 6,507 2,000 12,,180 12,300 12,440 12,307 3,000 18,480 18,600 18,720 18,600 4,000 24,300 24,440 24,580 24,440 5,000 30,320 331760 30,600 31,560 6,000 36,560 36,680 36,800 36,680 40000 35000 Lu 30000 U 0 25000 U- 20000 N 15000 ,LOU 10000 N5000 0 0 1000 2000 3000 4000 5000 GAUGE PRESSURE (psi) i 6000 7000 y = 6.1276x + 235.56 For a stressing force of 33,050 pounds, a gauge pressure of 5.500 is required. TECH: J. Hernandez JR cs