Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 5/30/2017 (2)-3, 0" y ARGO 00NSU1kTA1KT8 INQ 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type 111) Pour 2 Report Date: 5/30/2017 Stressed Date: 5/26/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T103 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T104 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T105 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T106 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T107 68 5.38 4.84 1 5.92 5.1 5.1 -5 5500 T108 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T109 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T110 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T111 68 5.38 4.84 5.92 5.4 5.4 0 5500 T112 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T113 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T114 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T115 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T116 1 68 5.38 4.84 5.92 5.3 5.3 1 -2 5500 T117 68 5.38 4.84 5.92 5.4 5.4 0 5500 T118 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T119 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T120 67 5.38 4.84 5.92 5.1 5.1 -5 5500 T121 67 5.38 4.84 5.92 5.1 5.1 -5 5500 T122 67 5.38 4.84 5.92 5.3 5.3 -2 5500 T123 69 5.50 4.95 6.05 5.3 5.3 -5 5500 T124 69 5.50 4.95 6.05 5.3 5.3 -5 5500 T125 60 4.75 4.28 5.23 4.5 4.5 -5 5500 T126 60 4.75 4.28 5.23 4.5 4.5 -5 5500 T127 60 4.75 4.28 5.23 4.5 4.5 -5 5500 T128 71 5.63 1 5.07 1 6.19 5.5 1 5.5 -2 5500 T129 71 1 5.63 1 5.07 6.19 5.4 1 5.4 -4 5500 Page 1 of 4 www.dallasfargo.com Checked By: r ARG CIONSUMANT$ TNC. 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 5/30/2017 Stressed Date: 5/26/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T130 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T131 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T132 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T133 68 5.38 4.84 5.92 5.8 5.8 7 5500 T134 74 6.00 5.40 6.60 5.9 5.9 -2 5500 T135 74 6.00 5.40 6.60 6.4 6.4 7 5500 T136 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T137 71 5.63 5.07 6.19 5.5 5.5 1 -2 5500 T138 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T139 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T140 71 5.63 5.07 6.19 T141 73 5.88 5.29 6.47 5.8 5.8 -2 5500 T142 73 5.80 5.22 6.38 5.8 5.8 -1 5500 T143 47 3.75 3.38 4.13 3.7 3.7 -1 5500 T144 47 3.75 3.38 4.13 3.6 3.6 -3 5500 T145 50 4.00 3.60 4.40 4.0 4.0 0 5500 T145-1 50 4.00 3.60 4.40 3.9 3.9 -3 5500 T146 30 2.25 2.03 2.48 2.4 2.4 1 6 5500 T147 30 2.25 2.03 2.48 2.4 2.4 6 5500 T148 89 7.13 6.42 7.84 T149 89 7.13 6.42 7.84 7.0 7.0 -2 5500 T150 89 7.13 6.42 7.84 7.0 7.0 -2 5500 T151 89 7.13 6.42 7.84 6.8 6.8 -5 5500 T152 89 7.13 6.42 7.84 6.8 6.8 -5 5500 T153 89 7.13 6.42 7.84 6.9 6.9 -4 5500 T154 89 7.13 6.42 7.84 6.9 6.9 -4 5500 T155 89 7.13 1 6.42 1 7.84 7.0 7.0 1 -2 1 5500 Page 2 of 4 www.dallasfargo.com - Checked By: f AUGO OONSUIMANTS I C 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 5/30/2017 Stressed Date: 5/26/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T156 89 7.13 6.42 7.84 7.1 7.1 0 5500 T157 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T158 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T159 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T160 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T161 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T162 92 7.38 6.64 1 8.12 7.0 7.0 -5 5500 T163 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T164 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T165 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T166 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T167 92 7.38 6.64 8.12 7.0 7.0 1 -5 5500 T168 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T169 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T170 94 7.50 6.75 1 8.25 7.5 7.5 0 5500 T171 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T172 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T173 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T174 94 7.50 6.75 8.25 7.3 7.3 -3 5500 T175 1 94 7.50 6.75 8.25 7.1 7.1 -5 5500 T176 94 7.50 6.75 8.25 7.1 7.1 -5 5500 T177 94 7.50 6.75 8.25 7.1 7.1 -5 5500 T178 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T179 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T180 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T181 21 1.50 1.35 1.65 1.5 1 1.5 0 1 5500 T182 1 21 1.50 1.35 1.65 1.5 1 1 1.5 0 1 5500 Page 3 of 4 www.dallasfargo.com Checked By: v Y ARCO COOS X-TANTS, INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 5/30/2017 Stressed Date: 5/26/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T183 21 1.50 1.35 1.65 1.6 1 1.6 8 5500 T184 21 1.50 1.35 1.65 1.5 1.5 0 5500 T185 18 1.25 1.13 1.38 1.3 1.3 4 5500 T186 50 4.00 3.60 4.40 3.9 3.9 -3 5500 T187 1 50 1 4.00 3.60 4.40 3.8 3.8 1 -6 1 5500 T188 1 50 1 4.00 1 3.60 4.40 1 3.8 1 1 3.8 1 -6 1 5500 * Repair Required. Page 4 of 4 www.dallasfargo.com Checked By: RAM S/N: GAUGE: PUMP S/N: PSL -3543 R-129 337463 CALIBRATION STANDARD: Ready Cable ine. 4416 Keller Hicks Rd., Fort Worth, TX 76244 817.379.6553 Main 817.379.4007 Fax REPORT: EMILIO P-3500 STRAIN INDICATOR LOAD CELL 50 KIPS 4/3/2017 0148342 070202 Gauge Pressure (PSI) Load Cell Readings Average of Three Readings #1#2 #3 1,000 6,4.60 6,600 61,720 6,593 2,000 12,250 12,280 .12,310 12,280 3,000 18,640 18,662 18,694 18,665 4,000 24,710 24,738 24,760 24,736 5,000 30,400 30,440 30,465 30,435 6,000 36,610 36,650 36,680 36,647 40000 35000 W 30000 0 WO 25000 U- 20000 ? 15000 N y j 10000 W 5000 0 0 1000 2000 3000 4000 GAUGE PRESSURE (psi) 5000 6000 7000 For a stressing force of 33,050 pounds, a gauge pressure of _&E00 is required. Y = 6.0229x + 479.16 TECH: J. Hernandez ]R TB