Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 5/30/2017 (3)I ARGO 00NSUX.TA1qTa INC_ 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report ** Client: JLB Partners, LP Report Date: 5/30/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/22/17-5/30/17 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: 3570-8444-015 Calibration Date: 4/4/17-3/3/17 Gauge No.: R -156/R-56 Pump No.: 367282/341941 Location: Floor Slab Building 17 (Type II -A) Pour 4 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (pSI) T1 30 2.25 2.03 2.48 2.3 2.3 2 5500 T2 30 2.25 2.03 1 2.48 2.3 2.3 2 5500 T3 65 5.25 4.73 5.78 4.9 4.9 -7 5500 T4 65 5.25 4.73 5.78 5.0 5.0 -5 5500 T5 65 5.25 4.73 5.78 5.0 5.0 -5 5500 *T6 65 5.25 4.73 5.78 5.5 5.5 5 5500 T7 65 5.25 4.73 5.78 5.3 5.3 1 5500 T8 65 5.25 4.73 5.78 5.0 5.0 -5 5500 T9 65 5.25 4.73 5.78 5.0 5.0 -5 5500 T10 65 5.25 4.73 5.78 4.9 4.9 -7 5500 T11 65 5.25 4.73 5.78 5.2 5.2 -1 5500 T12 65 5.25 4.73 5.78 5.1 5.1 -3 5500 T13 67 5.38 4.84 5.92 5.3 5.3 -1 5500 T14 67 5.38 4.84 5.92 5.0 5.0 -7 5500 T15 67 5.38 4.84 5.92 5.3 5.3 -1 5500 T16 67 5.38 4.84 5.92 5.4 5.4 0 5500 T17 67 5.38 4.84 5.92 5.5 5.5 2 5500 T18 67 5.38 4.84 5.92 5.2 5.2 -3 5500 T19 67 5.38 4.84 5.92 5.3 5.3 -1 5500 T20 67 5.38 4.84 5.92 5.5 5.5 2 5500 T21 67 5.38 4.84 5.92 5.6 5.6 4 5500 T22 67 5.38 4.84 5.92 5.1 5.1 -5 5500 T23 67 5.38 4.84 5.92 5.2 5.2 -3 5500 T24 67 5.38 4.84 5.92 5.3 5.3 -1 5500 T25 65 5.25 4.73 1 5.78 5.4 5.4 3 5500 T26 65 5.25 4.73 5.78 5.3 1 5.3 1 5500 T27 65 5.25 4.73 5.78 5.2 5.2 1 -1 5200j r Page 1 of 3 www.dallasfargo.com Checked By: V v,- iF'AROO CONSUETANTS,_INCA 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report ** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: 3570-8444-015 Gauge No.: R -156/R-56 Location: Floor Slab Building 17 (Type 11-A) Pour 4 Report Date: 5/30/2017 Stressed Date: 5/22/17-5/30/17 Project No: M16-4962 Calibration Date: 4/4/17-3/3/17 Pump No.: 367282/341941 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in Elongation Final Pressure (PSI) T28 65 5.25 4.73 5.78 5.3 5.3 1 5500 T29 30 2.25 2.03 1 2.48 2.3 2.3 2 5500 T30 30 2.25 2.03 2.48 2.2 2.2 -2 5500 T31 30 2.25 2.03 2.48 2.2 2.2 -2 5500 T32 30 2.25 2.03 2.48 2.2 2.2 -2 5500 T33 1 15 1.00 0.90 1.10 1.0 1.0 0 5500 T34 15 1.00 0.90 1 1.10 1.0 1.0 0 5500 T35 71 5.63 5.07 6.19 5.8 5.8 3 5500 T36 71 5.63 5.07 6.19 5.9 5.9 5 5500 T37 71 5.63 5.07 6.19 5.8 5.8 3 5500 T38 71 5.63 5.07 1 6.19 5.9 5.9 5 5500 T39 71 5.63 5.07 6.19 5.9 5.9 5 5500 T40 71 5.63 5.07 6.19 5.8 5.8 3 5500 T41 74 6.00 5.40 6.60 5.7 5.7 -5 5500 T42 74 6.00 5.40 6.60 5.8 5.8 -3 5500 T43 68 5.38 4.84 5.92 5.3 5.3 -1 5500 T44 68 5.38 4.84 5.92 5.2 5.2 -3 5500 T45 68 5.38 4.84 5.92 5.4 5.4 0 5500 T46 68 5.38 4.84 5.92 5.5 5.5 2 5500 T47 68 5.38 4.84 5.92 5.3 5.3 -1 5500 T48 71 5.63 5.07 6.19 5.8 5.8 3 5500 *T49 71 5.63 5.07 6.19 5.8 5.8 3 5500 T50 58 4.63 4.17 5.09 4.5 4.5 -3 5500 T51 58 4.63 4.17 5.09 4.6 4.6 -1 5500 T52 26 1.88 1.69 1 2.07 1.9 1.9 1 5500 T53 26 1.88 1.69 2.07 1.8 1.8 1 -4 1 5500 T54 26 1.88 1.69 2.07 1.9 1 1 1.9 1 5 00 Page 2 of 3 www.dallasfargo.com Checked By: �t' q � F'ARGO CONSUETANTS -INC. 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD **Revised Report ** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: 3570-8444-015 Gauge No.: R -156/R-56 Location: Floor Slab Building 17 (Type II -A) Pour 4 Report Date: 5/30/2017 Stressed Date: 5/22/17-5/30/17 Project No: M16-4962 Calibration Date: 4/4/17-3/3/17 Pump No.: 367282/341941 Tolerance: ± 100 Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T55 26 1.88 1.69 2.07 1.9 1.9 1 5500 T56 70 5.50 4.95 6.05 5.2 5.2 -5 5500 *T57 70 5.50 4.95 6.05 5.7 5.7 4 5500 T58 69 5.50 4.95 6.05 5.3 5.3 -4 5500 T59 69 5.50 4.95 6.05 5.4 5.4 -2 5500 T60 1 69 5.50 4.95 6.05 5.2 5.2 -5 5500 T61 72 5.75 5.18 6.33 5.5 5.5 -4 5500 T62 72 5.75 5.18 6.33 5.8 5.8 1 5500 T63 69 5.50 4.95 1 6.05 5.6 5.6 2 5500 T64 1 69 5.50 4.95 6.05 5.5 5.5 0 5500 T65 69 5.50 4.95 6.05 5.3 5.3 -4 5500 T66 69 5.50 4.95 6.05 5.2 5.2 -5 5500 T67 69 5.50 4.95 6.05 5.3 5.3 -4 5500 T169 26 1.88 1.69 2.07 2.0 2.0 1 6 5500 *T170 26 1.88 1.69 2.07 1.8 1 1.8 1 -4 5500 Revised report reflecting the elongations recorded for * cables stressed on 5/30/17. Page 3 of 3 www.dallasfargo.com ", Checked By. 'j, - RCi Ready Cable ine. 4416 Keller Hicks Rd., Fort Worth, TX 76244 817.379.6553 Main 817.379.4007 Fax REPORT: CARLOS RAM S/N: 08444-015 GAUGE: R-56 -- PUMP S/N,- 341941 z DATE: 3/3/2017 CALIBRATION STANDARD: P-3500 STRAIN INDICATOR 0148342 � LOAD CELL 50 KIPS 070202 Gauge Pressure (PSI) Load Cell Readings Average of Three Readings #1 #2 #3 1,000 6,120 6,240 6,380 6,247 2,000 12,400 12,520 12,660 12,527 3,000 18,580 18,700 18,720 18,667 4,000 24,360 24,480 24,620 24,487 5,000 30,460 30,580 30,720 30,587 6,000 36,620 36,740 36,780 36,713 40000 35000 w 30000 25000 O 20000 N 15000 N LU 10000 5000 0 0 1000 2000 3000 4000 5000 6000 7000 GAUGE PRESSURE (psi) y = 6.0667x + 304-44 For a stressing force of 33,050 pounds, a gauge pressure of 5.500 is required. TECH: J. Hernandez