HomeMy WebLinkAboutFargo Consultants, Inc. - 5/18/2017 (4)■ 0
FARGO CONSULTANTS, INC
2324 Fabens Rd. • 13allas, Texas 7522:
'rr]. 214-352-4100 Fax. 214-352-4811
REPORT OF FIELD COMPACTION Page I of I
Tested For: JLB Partners, LP Date Performed: 5/18/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 12 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max DD (pct) DD Range (%) MC Range
8 Reddish Brown and Tan CLAYEY SAND 13 115 Min. 95 -2 to +2
Field Test Results
Test Elevation
ift Location
No. IL
191 FG -6' SANITARY SEWER LINE SS -6 STATION 5+40
192 FG -5' SANITARY SEWER LINE SS -6 STATION 5+60
Source of Compaction Requirements: Geotechnical Report
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Proctor
DryDensity
No
(pcfi
8
110.8
8
111.6
Percent
Percent
Moisture
Density
13.4
96.3
13.1
97
Respectfully Submitted,
Farga�__onsra ants, Inc.
C y Moore, CET
rrterials Testing Division
'Me information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotecbnical Engineering • Construction Materials Testing • Environmental Services
www.dallasfarfo.com