HomeMy WebLinkAboutFargo Consultants, Inc. - 2/11/2017 (4)FRItriQ a6RS.VYdl,'A2iTS, INC.
2324 Fabens lid. • Dallas, Texas 75225
Tel. 214-352-4100 Pax. 214-352-4811
REPORT OF FIELD COMPACTION Page 1 of 1
Tested For: JLB Partners, LP Date Performed: 2/11/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 12 Inches
Test
Moisture -Density Relations
Proctor No.
Material Description Opt. MC(Vo) Max DD (pcfi
DD Range (%)
MC Range
1
Light Gray SANDY CLAY 18.9 105.5
95 to 100
0 to +4
3
Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1
95 to 100
0 to +4
5
Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1
95 to 100
0 to +4
Field Test Results
Test
Elevation
Location
No.
/L ift
34
FG -5'
SANITARY SEWER LINE SS -7 STATION 0+50
35
FG -4'
SANITARY SEWER LINE SS -7 STATION 0+50
36
FG -3'
SANITARY SEWER LINE SS -7 STATION 0+50
Source of Compaction Requirements: Geotechnical Report
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Proctor DryDensity
No (pcf)
1 102.1
5 101.7
3 99.1
Percent Percent
Moisture Density
19.3 96.8
17.2 95.9
19.5 96.1
Respectfully Submitted,
Farm Cylaultant
file.
laleria'ls
oore, CET
I. Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dallasfarffo.com