Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/9/2017 (7)FAnGo CONSULTANTS, INC 2324 Fabens Rd. • Dallas, Tcxas 7522: 'Vel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 1 Tested For: JLB Partners, LP Date Performed: 2/9/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth: 12 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 95 to 100 0 to +4 Field Test Results Test Elevation ift Location No. IL 21 FG -3' STORM DRAIN LINE F STATION 1+45 22 FG -3' STORM DRAIN LINE G STATION 0+50 Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Proctor DryDensity No (pcf) 1 104.6 5 101.7 Percent Percent Moisture Density 19.5 99.1 17.9 95.9 Respectfully Submitted, Fargo Consult nis, Inc. it Moore, CET fifer Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering •Construction Materials Te ting • Environmental Servicer www.dallasfar,go.com