HomeMy WebLinkAboutFargo Consultants, Inc. - 3/1/2017 (6)-110I =a. rAnao. CowSUX.TA"Ts. TKCS, 2324 Fabens Rd.. Dallas, Texas 7522; Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 3/1/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth: 12 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www.dallasfar.go.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcj) DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4 2 Light Gray CLAYEY SAND and gravel intermixed 10.2 116.4 95 to 100 0 to +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 95 to 100 0 to +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 95 to 100 0 to +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 95 to 100 0 to +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 98 FG -4' SANITARY SEWER LINE SS -3 STATION 3+30 1 101.3 20.7 96 99 FG -3' SANITARY SEWER LINE SS -3 STATION 3+30 4 93.1 23.8 96.2 100 FG -2' SANITARY SEWER LINE SS -3 STATION 3+30 3 98.5 20.3 95.5 101 FG -1' SANITARY SEWER LINE SS -3 STATION 3+30 3 99.4 20.1 96.4 102 FG SANITARY SEWER LINE SS -3 STATION 3+30 4 94.5 23.8 97.6 103 FG -2' WATER LINE GRID POINT N.9-29 1 102.1 19,6 96.8 104 FG -1' WATER LINE GRID POINT N,9-29 2 112.6 13.2 96.7 105 FG WATER LINE GRID POINT N.9-29 2 113.2 12.5 97.3 106 FG -3' WATER LINE GRID POINT N.9-38 1 102.3 19.1 97 107 FG -2' WATER LINE GRID POINT N.9-38 5 102.1 17.3 96.2 108 FG -1' WATER LINE GRID POINT N,9-38 3 99.1 20.2 96.1 109 FG WATER LINE GRID POINT N.9-38 5 101.8 17.5 95.9 110 FG -3' BLDG. 2 WATER SERVICE LINE 1 101.9 19.3 96.6 111 FG -2' BLDG. 2 WATER SERVICE LINE 5 101.3 17.5 95.5 112 FG -1' BLDG 2 WATER SERVICE LINE 3 99.3 20.3 96.3 113 FG BLDG 2 WATER SERVICE LINE 5 101.6 17.6 95.8 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www.dallasfar.go.com )5 xnrcpo aorearnsarrT�s. iirn. REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Fabens Rd. • Dallas, "Texas 7522: Tel. 214-352-4100 Fax. 214-352-4811 Page 2 of 2 Date Performed: 3/1/2017 Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 12 Inches Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Respectfully Submitted, Farge,C'onsulmnts, Inc. , CET sting Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www. dallasfaroo. com