REPORT OF FIELD COMPACTION Page I of 1
Tested For: JLB Partners, LP Date Performed: 3/20/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 12 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range
1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4
Test Elevation
No. ILift
Location
Field Test Results
152 FG WATER LINE GRID POINT R-18 (NORTH SITE GRID)
Source of Compaction Requirements: Geotechnical Report
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines
Test locations are referenced using an in-house system and are approximate.
Proctor DryDensity Percent Percent
No (pcfJ Moisture Density
1 101.6 19.8 96.3
Respectfully Submitted,
Fargo oansultants; Inc.
/G 7 Moore, CET
Materials Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services