Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/4/2017 (3)R7700 2324 Nabcns Rd. • Dallas Tcxas 7522; 1;A 14 r;0NNuVrAN't's,INC, Tel. 214-352-41001,ax.214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 1 Tested For: JLB Partners, LP Date Performed: 3/4/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 12 Inches Moisture -Density Relations Proctor No. Material Description Opt. MQ1%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 95 to 100 0 to +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. Location /Lift No (pcf) Moisture Density 125 FG -2' WATER LINE EAST OF BLDG. 1 GRID POINT V 5-38 9 (SOUTH SITE GRID) 3 98.1 19.9 95.2 126 FG -1' WATER LINE EAST OF BLDG. 1 GRID POINT V.5-38 9 (SOUTH SITE GRID) 1 102.2 19.2 96.9 127 FG WATER LINE EAST OF BLDG. 1 GRID POINT V.5-38 9 (SOUTH SITE GRID) 1 101.8 21.3 96.5 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo o/� ltants, Inc: Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. 1y�� tom"'! Moore, CET fIlI7 Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and arc not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfari7o.com