Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 4/1/2017 (5)OO gnrtco cbxrcua:rnNz ti, INC, 2324 Fabens Rd. • Dallas, "Texas 75225 Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of I Tested For: JLB Partners, LP Date Performed: 4/1/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth: 12 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pct DD Range (%) MC Range 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 95 to 100 0 to +4 Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Proctor DryDensity No (pcf) Field Test Results Test Elevation 103 5 104.3 Location No. ILift 105.4 161 FG -1' SANITARY SEWER LINE SS6 MANHOLE STATION 7+63 N. QUAD 162 FG -8' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 W. QUAD 163 FG -7' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 N. QUAD 164 FG -6' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 E. QUAD 165 FG -5' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 S. QUAD 166 FG SANITARY SEWER LINE SS6 MANHOLE STATION 7+63 S. QUAD 167 FG -4' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 N. QUAD 168 FG -3' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 E. QUAD 169 FG -2' SANITARY SEWER LINE SS6 MANHOLE STATION 2+38 S QUAD Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Proctor DryDensity No (pcf) 5 106 5 103 5 104.3 5 103.5 5 105.4 5 104.5 5 104.2 5 103.8 5 104 Percent Percent Moisture Density 16.8 99.9 20.8 97.1 19.6 983 19.2 97.5 19.1 99.3 16.9 98.5 17.2 98.2 18 97.8 17.6 98 Respectfully Submitted, Fargo onsrr ants, Inc. GrGlf Gr y Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com