CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 795
Ambient Temp. (°F): 75
Concrete Temp. (°F): 75
Time Batched: 7:04 AM
Time Sampled: 8:10 AM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / Osbur
Mix Id Number: F9506
Air Content (%): 1.5 (ASTM C231)
Water Added (gal): 10
Slump (inches) 6 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point W-41
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
1A
3
6/2/2017
27305
2170
1B
7
6/6/2017
36645
2920
1 C
28
6/27/2017
38235
3040
1D
28
6/27/2017
38545
3070
1E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dagasfargo.com
2324 Fabens Rd. • Dallas, Texas 75229
r
Fnxaa CONSULTANTS, INC. Tel. 214-352-4100 Fax. 214-352-4811
CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 802
Ambient Temp. (°F): 78
Concrete Temp. (°F): 76
Time Batched: 7:56 AM
Time Sampled: 9:05 AM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / 1005
Mix Id Number: F9506
Air Content (%): 1.2 (ASTM C231)
Water Added (gal): 0
Slump (inches) 6 1/2 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point V-40
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
2A
3
6/2/2017
28475
2270
2B
7
6/6/2017
28950
2300
2C
28
6/27/2017
42890
3410
2D
28
6/27/2017
45405
3610
2E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dagasfargo.com
2324 Fabens Rd. • Dallas, Texas 75229
r
Fnxaa CONSULTANTS, INC. Tel. 214-352-4100 Fax. 214-352-4811
CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 807
Ambient Temp. (°F): 85
Concrete Temp. (°F): 76
Time Batched: 10:03 AM
Time Sampled: 11:10 AM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / Osbur
Mix Id Number: F9506
Air Content (%): 1.8 (ASTM C231)
Water Added (gal): 0
Slump (inches) 6 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point U-40
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
3A
3
6/2/2017
23445
1870
3B
7
6/6/2017
26515
2110
3C
28
6/27/2017
44695
3560
3D
28
6/27/2017
45185
3600
3E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dagasfargo.com
2324 Fabens Rd. • Dallas, Texas 75229
r
Fnxaa CONSULTANTS, INC. Tel. 214-352-4100 Fax. 214-352-4811
CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 811
Ambient Temp. (°F): 88
Concrete Temp. (°F): 82
Time Batched: 10:34 AM
Time Sampled: 11:44 AM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / Osbur
Mix Id Number: F9506
Air Content (%): 1.9 (ASTM C231)
Water Added (gal): 0
Slump (inches) 6 3/4 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point T-39
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
4A
3
6/2/2017
24600
1960
4B
7
6/6/2017
25340
2020
4C
28
6/27/2017
38490
3060
4D
28
6/27/2017
39345
3130
4E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dagasfargo.com
2324 Fabens Rd. • Dallas, Texas 75229
r
Fnxaa CONSULTANTS, INC. Tel. 214-352-4100 Fax. 214-352-4811
CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 818
Ambient Temp. (°F): 90
Concrete Temp. (°F): 85
Time Batched: 12:09 PM
Time Sampled: 1:05 PM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / Osbur
Mix Id Number: F9506
Air Content (%): 2.1 (ASTM C231)
Water Added (gal): 0
Slump (inches) 6 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point R-39
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
5A
3
6/2/2017
23630
1880
5B
7
6/6/2017
28360
2260
5C
28
6/27/2017
42550
3390
5D
28
6/27/2017
44215
3520
5E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www.dagasfargo.com
2324 Fabens Rd. • Dallas, Texas 75229
r
Fnxaa CONSULTANTS, INC. Tel. 214-352-4100 Fax. 214-352-4811
CONCRETE COMPRESSIVE STRENGTH REPORT
CLIENT: JLB Partners, LP
PROJECT: Grapevine Bluffs
Grapevine, Texas
Contractor: Fx Concrete
Ticket No.: 824
Ambient Temp. (°F): 90
Concrete Temp. (°F): 85
Time Batched: 2:58 PM
Time Sampled: 4:00 PM
Weather Condition: Clear
SAMPLE DATE 5/30/2017
JOB NO.: M16-4962
CONCRETE INFORMATION
Concrete Supplier: FX Material
Plant/Truck: 01 / 1005
Mix Id Number: F9506
Air Content (%): 1.9 (ASTM C231)
Water Added (gal): 0
Slump (inches) 6 1/4 (ASTM C143)
Location of Placement: Floor Slab, Bldg. 10 Pour 1 -Grid Point T-42
Mix Design Strength of Concrete ( 3000 psi/28 days)
Cylinder Number
Age
(days)
Date Tested
Total Load
(pounds)
Compressive
Strength (psi)
6A
3
6/2/2017
30125
2400
6B
7
6/6/2017
41110
3270
6C
28
6/27/2017
53665
4270
6D
28
6/27/2017
50190
3990
6E
Hold
Cylinder Type: Nominal Cylinder Size (ASTM C39) 4 -inch by 8 -inch
Test Methods: Making and Curing (ASTM C31) Testing Methods (ASTM C39)
Remarks: Informed superintendent of all field test results.
Test locations are referenced using an in-house system and are approximate.
Technician M. Strom
Fargo Consultants, Inc.
Davis Udeogu
Project Manager
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.