HomeMy WebLinkAboutFargo Consultants, Inc. - 6/2/2017 (3)CONSUL:PAN'I'S, INC, 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3574 Gauge No.: R-153 Location: Floor Slab Building 15 (Type XI) Report Date: 6/2/2017 Stressed Date: 5/24/17-6/2/17 Project No: M16-4962 Calibration Date: 3/28/2017 Pump No.: 362981 Tolerance: ± 10% Cable ID Strand Mark Required Elongation Inch ) Minimum Elongation Inch (Inch) Maximum Elongation Inch (Inch) First Elongation Inch (Inch) Second Elongation Inch (Inch) Total Elongation Inch (Inch) Variation in % Elongation g Final Pressure (PSI) T1 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T2 35 2.63 2.37 2.89 2.6 2.6 1 -1 5500 T3 35 2.63 2.37 2.89 2.6 2.6 -1 5500 T4 35 2.63 2.37 2.89 2.8 2.8 6 5500 T5 121 9.63 8.67 10.59 5.1 5.2 10.3 7 5500 T6 121 9.63 8.67 10.59 5.3 4.9 10.2 6 5500 T7 121 9.63 8.67 1 10.59 4.1 6.1 10.2 6 5500 T8 1 121 9.63 8.67 10.59 3.7 5.9 9.6 0 5500 T9 121 9.63 8.67 10.59 5.3 5.0 10.3 7 5500 T10 121 9.63 8.67 10.59 5.2 4.7 9.9 3 5500 * T11 121 9.63 8.67 10.59 5.2 4.1 9.3 -3 5500 T12 121 9.63 8.67 10.59 5.3 4.9 10.2 6 5500 T13 121 9.63 8.67 10.59 5.1 5.1 10.2 6 5500 T14 121 9.63 8.67 10.59 5.2 5.0 10.2 6 5500 T15 121 9.63 8.67 10.59 5.1 4.8 9.9 3 5500 T16 121 9.63 8.67 10.59 5.0 4.8 9.8 2 5500 T17 121 9.63 8.67 10.59 5.2 4.9 10.1 5 5500 T18 121 9.63 8.67 10.59 4.9 4.7 9.6 0 5500 T19 121 9.63 8.67 10.59 5.2 4.8 10.0 4 5500 T20 121 9.63 8.67 1 10.59 5.1 4.9 10.0 4 5500 T21 1 121 9.63 8.67 10.59 5.0 4.1 9.1 -6 5500 T22 18 1.25 1.13 1.38 1.2 1.2 -4 5500 T23 18 1.25 1.13 1.38 1.3 1.3 4 5500 T24 28 2.13 1.91 1 2.34 2.1 2.1 -1 5500 T25 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T26 28 2.13 1.91 2.34 2.2 1 2.2 4 5500 T27 28 1 2.13 1.91 2.34 2.2 1 2.2 1 4 55QO Page 1 of 4 www.dallasfargo.com Checked By`� I O r AR00 CONSUr.T'ANTS INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3574 Gauge No.: R-153 Location: Floor Slab Building 15 (Type XI) Report Date: 6/2/2017 Stressed Date: 5/24/17-6/2/17 Project No: M16-4962 Calibration Date: 3/28/2017 Pump No.: 362981 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T28 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T29 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T30 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T31 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T32 31 2.38 2.14 2.62 2.3 2.3 -3 5500 T33 31 2.38 2.14 1 2.62 2.4 2.4 1 5500 T34 28 2.13 1.91 2.34 2.2 2.2 4 5500 T35 28 2.13 1.91 2.34 2.3 2.3 8 5500 T36 28 2.13 1.91 2.34 2.2 2.2 4 5500 T37 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T38 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T39 28 2.13 1.91 2.34 2.2 2.2 4 5500 T40 28 2.13 1.91 2.34 2.2 2.2 4 5500 T41 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T42 28 2.13 1.91 2.34 2.3 2.3 8 5500 T43 28 2.13 1.91 2.34 2.2 2.2 4 5500 T44 28 2.13 1.91 2.34 2.2 2.2 4 5500 T45 28 2.13 1.91 2.34 2.2 2.2 4 5500 T46 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T47 28 2.13 1.91 1 2.34 2.2 2.2 4 5500 T48 18 1.25 1.13 1.38 1.2 1.2 -4 5500 T49 18 1.25 1.13 1.38 1.3 1.3 4 5500 T50 31 2.38 2.14 2.62 2.3 2.3 -3 5500 T51 31 2.38 2.14 2.62 2.4 2.4 1 5500 T52 28 2.13 1.91 2.34 2.3 2.3 8 5500 T53 28 2.13 1.91 2.34 1 2.3 1 2.3 1 8 5500 T54 1 28 1 2.13 1.91 2.34 2.2 2.2 4 5590 Page 2 of 4 www.dallasfargo.com Checked By 1f' -R .176 0 AnG0 CONSULTANTSINC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Report Date: 6/2/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/24/17-6/2/17 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3574 Calibration Date: 3/28/2017 Gauge No.: R-153 Location: Floor Slab Building 15 (Type X1) Pump No.: 362981 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in oho Elongation Final Pressure (PSI) T55 28 2.13 1.91 2.34 2.2 2.2 4 5500 T56 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T57 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T58 31 2.38 2.14 2.62 2.3 2.3 -3 5500 T59 31 2.38 2.14 2.62 2.3 2.3 -3 5500 T60 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T61 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T62 28 2.13 1.91 2.34 2.2 2.2 1 4 5500 T63 28 2.13 1.91 2.34 2.2 2.2 4 5500 T64 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T65 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T66 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T67 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T68 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T69 28 2.13 1.91 2.34 2.0 2.0 1 -6 5500 T70 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T71 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T72 28 2.13 1.91 2.34 2.0 2.0 -6 5500 T73 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T74 18 1.25 1.13 1.38 1.2 1.2 -4 5500 T75 18 1.25 1.13 1.38 1.2 1.2 -4 5500 T76 31 2.38 2.14 2.62 2.3 2.3 1 -3 5500 T77 31 2.38 2.14 2.62 2.4 2.4 1 5500 T78 28 2.13 1.91 2.34 2.2 2.2 4 5500 T79 28 2.13 1.91 2.34 2.2 2.2 4 5500 T80 28 2.13 1.91 2.34 2.2 1 2.2 4 5500 T81 28 1 2.13 1.91 2.34 1 2.3 1 1 2.3 1 8 5500 v Page 3 of 4 www.dallasfargo.com Checked By: t AKGO C ONSUETANTS iNO 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3574 Gauge No.: R-153 Location: Floor Slab Building 15 (Type XI) Report Date: 6/2/2017 Stressed Date: 5/24/17-6/2/17 Project No: M16-4962 Calibration Date: 3/28/2017 Pump No.: 362981 Tolerance: ± 10% * Revised report reflecting the elongations recorded on 6/2/17 for the repaired cable . Page 4 of 4 www.dallasfargo.com CheckedeY7:)� Strand Required Minimum Maximum First Second Total Variation in Final Pressure Cable ID Mark Elongation Elongation Elongation Elongation Elongation Elongation oho (PSI) (Inch) (Inch) (Inch) Inch) Inch) (Inch) Elongation T82 28 2.13 1.91 2.34 2.2 2.2 4 5500 T83 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T84 28 2.13 1.91 2.34 2.1 2.1 -1 5500 T85 28 2.13 1.91 1 2.34 2.1 2.1 -1 5500 * Revised report reflecting the elongations recorded on 6/2/17 for the repaired cable . Page 4 of 4 www.dallasfargo.com CheckedeY7:)�