Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 6/13/2017z. a ELRGFO Oobwsu&TANTS INC: 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: R-18 Location: Floor Slab Building 17 (Type H -A) Pour 1 Report Date: 6/13/2017 Stressed Date: 6/2/17-6/12/17 Project No: M16-4962 Calibration Date: 3/28/17-4/3/17 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (pSI) T1 33 2.50 2.25 2.75 2.6 2.6 4 5500 T2 1 71 5.63 5.07 6.19 5.8 5.8 3 5500 T3 71 5.63 5.07 1 6.19 5.5 5.5 -2 5500 T4 68 5.38 4.84 5.92 5.2 5.2 -3 5500 T5 68 5.38 4.84 5.92 5.2 5.2 -3 5500 T6 68 5.38 4.84 5.92 5.5 5.5 2 5500 T7 70 5.50 4.95 1 6.05 5.9 5.9 7 5500 T8 70 5.50 4.95 6.05 5.6 5.6 2 5500 T9 68 5.38 4.84 5.92 5.4 5.4 0 5500 T10 68 5.38 4.84 5.92 5.6 5.6 4 5500 T11 68 5.38 4.84 1 5.92 5.5 5.5 2 5500 T12 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T13 68 5.38 4.84 5.92 5.0 5.0 -7 5500 T14 29 2.13 1.92 2.34 2.2 2.2 3 5500 T15 29 2.13 1.92 2.34 2.1 2.1 -1 5500 T16 28 2.13 1.92 2.34 2.1 2.1 -1 5500 T17 60 4.75 4.28 5.23 4.9 4.9 3 5500 T18 60 4.75 4.28 5.23 4.8 4.8 1 5500 T19 60 4.75 4.28 5.23 4.5 4.5 -5 5500 T20 72 5.75 5.18 1 6.33 6.1 6.1 6 5500 T21 72 5.75 5.18 6.33 5.9 5.9 1 3 5500 T22 68 5.38 4.84 5.92 5.8 5.8 8 5500 T23 68 5.38 4.84 5.92 5.5 5.5 2 5500 T24 68 5.38 4.84 5.92 5.5 5.5 2 5500 T25 1 68 5.38 4.84 5.92 5.8 5.8 8 5500 T26 68 5.38 4.84 5.92 1 5.4 5.4 0 5500 T27 68 5.38 1 4.84 5.92 5.8 5.8 8 5500 Page 1 of 3 www.dallasfargo.com Checked By: S r ARCO CONSUINANT XXNC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: R-18 Location: Floor Slab Building 17 (Type H -A) Pour 1 Report Date: 6/13/2017 Stressed Date: 6/2/17-6/12/17 Project No: M16-4962 Calibration Date: 3/28/17-4/3/17 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T28 74 6.00 5.40 6.60 5.9 5.9 -2 5500 T29 74 6.00 5.40 6.60 6.1 6.1 2 5500 T30 74 6.00 5.40 6.60 5.9 5.9 -2 5500 T31 71 5.63 5.07 6.19 5.9 5.9 5 5500 T32 71 5.63 5.07 6.19 5.8 5.8 3 5500 T33 71 5.63 5.07 6.19 5.6 5.6 -1 5500 T34 71 5.63 5.07 6.19 5.8 5.8 3 5500 T35 71 5.63 5.07 6.19 5.6 5.6 -1 5500 T36 73 5.88 5.29 6.47 5.6 5.6 1 -5 5500 T37 73 5.88 5.29 6.47 5.5 5.5 -6 5500 T38 47 3.75 3.38 4.13 3.5 3.5 -7 5500 T39 21 1.50 1.35 1.65 1.5 1.5 0 5500 T40 21 1.50 1.35 1.65 1.4 1.4 -7 5500 T41 21 1.50 1.35 1.65 1.6 1.6 7 5500 T42 21 1.50 1.35 1.65 1.5 1.5 0 5500 T43 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T44 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T45 1 35 2.63 2.37 2.89 2.8 2.8 6 5500 T46 73 5.88 5.29 6.47 5.6 5.6 -5 5500 T47 73 5.88 5.29 6.47 5.9 5.9 0 1 5500 T48 73 5.88 5.29 6.47 6.0 6.0 2 5500 T49 73 5.88 5.29 6.47 6.1 6.1 4 5500 T50 73 5.88 5.29 6.47 6.0 6.0 2 5500 T51 73 5.88 5.29 6.47 6.2 6.2 5 5500 T52 73 5.88 5.29 6.47 6.0 6.0 2 5500 T53 70 5.50 4.95 6.05 5.8 5.8 5 5500 T54 70 5.50 1 4.95 6.05 1 5.8 1 5.8 5 5500 Page 2 of 3 www.dallasfargo.com Checked By� � d :-3, ■aARGO COTYsi)I,Ti11+7tB xrrc 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: R-18 Location: Floor Slab Building 17 (Type H -A) Pour 1 Report Date: 6/13/2017 Stressed Date: 6/2/17-6/12/17 Project No: M16-4962 Calibration Date: 3/28/17-4/3/17 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T55 70 5.50 4.95 6.05 5.9 5.9 7 5500 T56 1 70 5.50 4.95 6.05 5.7 5.7 4 5500 T57 70 5.50 4.95 6.05 5.8 5.8 5 5500 *T58 67 5.38 4.84 5.92 5.7 5.7 6 5500 T59 67 5.38 4.84 5.92 5.5 5.5 2 5500 T60 67 5.38 4.84 5.92 5.4 5.4 0 5500 T61 67 5.38 4.84 5.92 5.6 5.6 4 5500 T62 68 5.38 4.84 5.92 5.5 5.5 2 5500 T63 65 5.25 4.73 5.78 5.6 5.6 7 5500 T64 65 5.25 4.73 5.78 5.5 5.5 5 5500 T65 65 5.25 4.73 1 5.78 5.2 5.2 -1 5500 T66 65 5.25 4.73 5.78 5.5 5.5 5 5500 T67 65 5.25 4.73 5.78 5.6 5.6 7 5500 T68 65 5.25 4.73 5.78 5.6 5.6 7 5500 T69 65 5.25 4.73 5.78 5.5 5.5 5 5500 T70 65 5.25 4.73 5.78 5.5 5.5 5 5500 T71 65 5.25 4.73 5.78 5.3 5.3 1 5500 T72 65 5.25 4.73 1 5.78 5.4 5.4 3 5500 T73 1 25 1.88 1.69 2.07 1 1.9 1.9 1 1 5500 T74 25 1.88 1.69 2.07 2.0 2.0 6 5500 Revised report reflecting the elongations recorded for the * Repaired cable on 6/12/17. Page 3 of 3 www.dallasfargo.com Checked By: l --