REPORT OF FIELD COMPACTION Page 1 of 1
Tested For: JLB Partners, LP Date Performed: 2/10/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas _
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(Yo) Max DD (pcfi DD Range (%) MC Range
1 Light Gray SANDY CLAY 18.9
105.5
95 to 100
0 to +4
2 Light Gray CLAYEY SAND and gravel intermixed 10.2
116.4
95 to 100
0 to +4
5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8
106.1
95 to 100
0 to +4
Field Test Results
Test Elevation
Proctor
DryDensity
Percent
Percent
No. ILift Location
No
(pcfi
Moisture
Density
28 SG FIRE LANE GRID POINT R-13 (SOUTH SITE GRID)
2
110.8
11.3
95.2
29 SG FIRE LANE GRID POINT R-20 (SOUTH SITE GRID)
2
112.5
13.6
96.6
30 SG FIRE LANE GRID POINT V.3-14 (SOUTH SITE GRID)
1
104.7
18-9
99.2
31 SG FIRE LANE GRID POINT V 3-19 (SOUTH SITE GRID)
2
111
12.5
95.4
32 2ND WEST PARKING LOT AREA GRID POINT Y-3 (SOUTH SITE GRID)
5
101.7
19.1
95-9
33 8TH WEST PARKING LOT AREA GRID POINT H-6 (NORTH SITE GRID)
5
103.9
17
97.9
34 8TH WEST PARKING LOT AREA GRID POINT 1A-5 (SOUTH SITE GRID)
5
104
18.8
98
35 8TH WEST PARKING LOT AREA GRID POINT X-6 (SOUTH SITE GRID)
5
102.2
19-3
96.3
Source of Compaction Requirements: Geotechnical Report
Respectfully Submitted,
Fargousult Inc.
11 S!4
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Test locations are referenced using an in-house system and are approximate.
CET
raterieiOAOT4esting
Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in -their entirety.