Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 5/17/2017 (2)F:�_ GO _ rA"0 C v N R VITA NF1,J3, rr90. 2324 Fabens Rd. • Dallas, 'Texas 7522; 'Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 1 Tested For: JLB Partners, LP Date Performed: 5/17/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 2 Light Gray CLAYEY SAND and gravel intermixed 10.2 116.4 95 to 100 0 to +4 8 Reddish Brown and Tan CLAYEY SAND 13 115 Min. 95 -2 to +2 Field Test Results Test Elevation Location No. /Lift 116.2 207 FG FIRE LANE GRID POINT N-33 (N. SITE GRID) 208 FG PARKING AREA GRID POINT L.5-34.5 (N. SITE GRID) 209 FG FIRE LANE GRID POINT G-33.5 (N. SITE GRID) 210 FG PARKING AREA GRID POINT J-32 (N. SITE GRID) Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Proctor DryDensity No (pcfi 2 115.9 2 116.2 8 109.4 8 111.8 Percent Percent Moisture Density 12 99.6 13.4 99.8 13 95.1 13.8 97.2 Respectfully Submitted, Fargo vnsult ntr, Inc. C y 1lfnore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com