Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 6/5/2017F?60 _w FARGO CONSULTANTS, INC. DAILY FIELD REPORT Client: JLB Partners, LP Project Name: Grapevine Bluffs Project Location: Grapevine, Texas Service(s) Provided: Fire Proofing Thickness Determination Service(s) Performed By: BKH Inspection Services 2324 Fabens Rd. • DaRas, Texas 75229 Tel 214-3524100 Fax 214352-4811 Date Performed: 6/5/2017 FARGO Job No: M16-4962 Respectfully Submitted, Fargo Consultants, Inc. The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfargo.com BKH INSPECTION SERVICES., -LLC P.O Box 2472 Burleson, TX 76097 817-726-5456 bkhinspection(rD,Qmail.com www.bkhinspectionservices.com REPORT OF ULTRASONIC INSPECTION Client: Fargo Consultants, Inc. Project: Grapevine Bluffs Report No.: Project No.: Date of Service: Purchase Order No.: UT13048 M16-4962 06-05-2017 3505 Services: Coating Thickness Reading/Observation Page I of 1 s=.. u r, 71. Instrument/SN: Certification Date: Purpose of Test: Specification: Scan Sensitivity: Positector 6000-FKS3K87022 05-16-2016 Intumescent Coating Thickness Contract Documents Magnetic Induction Long. Freq. /Size: Shear Freq. /Size: Calibration: Couplant: FKS 1275655 N/A Defelsko Precision Standards. N/A Discrepancies/Comments: BKH Inspection Services arrived at the above location to perform a ultrasonic inspection with the results listed below: Item Quantity Description Results 1 Building Type V1 -S 2" floor level structural steel Intumescent Coating Thickness Grid lines A -C/1-7): 9 A) 9 columns tube steel have an average intumescent coatin thickness of 47 mils. 8 B) 8 beams (WF) have an average intumescent coating thickness of 64 mils. N�`I) CWI #97041661 Level II Technician BKH Inspection Services, LLC Limitations: The test results herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control, this document is not a warranty or guaranty of the components inspected, it is intended to provide information as to the components inspected