HomeMy WebLinkAboutFargo Consultants, Inc. - 3/8/2017 (3)2324 Fabens Road • Dallas, Texas 75229 FARGO CONSULTANTS, INC. Phone: 214-352-4100 • Fax: 214-352-4811 MORTAR COMPRESSIVE STRENGTH REPORT CLIENT: JLB Partners, LP PROJECT: Grapevine Bluffs Grapevine, TX Contractor: C&W Stonework Ticket No: On -Site Mix Ambient Temp (F): 71 Mortar Temp (F): 70 Time Batched: 2:10 PM Time Sampled: 2:25 PM Weather Condition: Clear SAMPLE DATE: 3/8/2017 FARGO JOB NO: M16-4962 MORTAR INFORMATION Mortar Supplier: - Plant/Truck: On -Site Mix Mix ID Number: - Air Content (%): N/A (ASTM C231) Water Added (gal): 0 Slump (inches): N/A (ASTM C143) Location of Placement: CMU North Retaining Wall — Elev. 3' to 4' Grid Points X-19 Mix Design Strength of Mortar 1800 si/28 days Cube Age Number (days) Date Tested Total Load (pounds) Compressive Strength ( si) IA 7 3/15/2017 7420 1850 IB 28 4/5/2017 10860 2710 IC 1 28 1 4/5/2017 10020 2500 Sample Type: 2 -inch x 2 -inch cubes Test Methods: Making and Curing (ASTM C102) Remarks: N/A indicates not applicable, Technician: A. Maya FARGO CONSULTANTS, INC. Checked B�� . Gary Moorb. CTT' Manager, Materials Testing Division LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering - Construction Materials Testing • Environmental Services www.dallasfargo.com