Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 6/9/20172324 Fabens Rd., Dallas, TX 75229 0 Tel. (214) 352-4100 Fax. (214) 352-4811 Al Q CpN$T3LTAI+iT8 INC FIELD POST TENSION STRESSING RECORD ** Revised Report ** Client: JLB Partners, LP Report Date: 6/9/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/26/17-6/7/17 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3543 Calibration Date: 4/3/2017 Gauge No.: 337463 Location: Floor Slab Building 14(Type Ill) Pour 2 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T103 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T104 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T105 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T106 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T107 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T108 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T109 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T110 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T111 68 5.38 4.84 5.92 5.4 5.4 0 5500 T112 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T113 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T114 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T115 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T116 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T117 68 5.38 4.84 5.92 5.4 5.4 0 5500 T118 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T119 71 5.63 5.07 6.19 5.5 5.5 1 -2 5500 T120 67 5.38 4.84 5.92 5.1 5.1 -5 5500 T121 67 5.38 4.84 5.92 5.1 5.1 -5 5500 T122 67 5.38 4.84 5.92 5.3 5.3 -2 5500 T123 69 5.50 4.95 6.05 5.3 5.3 -5 5500 T124 69 5.50 4.95 6.05 5.3 5.3 -5 5500 T125 60 4.75 4.28 5.23 1 4.5 4.5 -5 5500 T126 1 60 4.75 4.28 5.23 4.5 4.5 1 -5 5500 T127 60 4.75 4.28 5.23 4.5 4.5 -5 5500 T128 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T129 71 1 5.63 1 5.07 1 6.19 1 5.4 1 1 5.4 -4 1 5500 Page 1 of 4 www.dallasfargo.com Checked By: �� r�e 2324 Fabens Rd., Dallas; TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 !.FARGO GUN'SCYI';,L',f�lV'L'� , I1ti7C! FIELD POST TENSION STRESSING RECORD "Revised Report ** Client: JLB Partners, LP Report Date: 6/9/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/26/17-6/7/17 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3543 Calibration Date: 4/3/2017 Gauge No.: 337463 Pump No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in oho Elongation Final Pressure (PSI) T130 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T131 68 5.38 4.84 5.92 5.1 5.1 -5 5500 T132 68 5.38 4.84 5.92 5.3 5.3 -2 5500 T133 68 5.38 4.84 5.92 5.8 5.8 7 5500 T134 74 6.00 5.40 6.60 5.9 5.9 -2 5500 T135 74 6.00 5.40 6.60 6.4 6.4 7 5500 T136 71 5.63 5.07 6.19 5.4 5.4 -5 5500 T137 71 5.63 5.07 6.19 1 5.5 5.5 -2 5500 T138 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T139 71 5.63 5.07 6.19 5.5 5.5 -2 5500 *T140 71 5.63 5.07 6.19 6.0 6.0 7 5500 T141 73 5.88 5.29 6.47 5.8 5.8 -2 5500 T142 73 5.80 5.22 6.38 5.8 5.8 -1 5500 T143 47 3.75 3.38 4.13 3.7 3.7 -1 5500 T144 47 3.75 3.38 4.13 3.6 3.6 -3 5500 T145 50 4.00 3.60 4.40 4.0 4.0 0 5500 T145-1 50 4.00 3.60 4.40 3.9 3.9 -3 5500 T146 30 2.25 2.03 2.48 2.4 2.4 6 5500 T147 30 2.25 2.03 2.48 2.4 2.4 6 5500 *T148 89 7.13 6.42 7.84 7.5 7.5 5 5500 T149 89 7.13 6.42 7.84 7.0 7.0 -2 5500 T150 89 7.13 6.42 7.84 7.0 7.0 -2 5500 T151 89 7.13 6.42 7.84 6.8 6.8 -5 5500 T152 89 7.13 6.42 7.84 6.8 6.8 -5 5500 T153 89 7.13 6.42 1 7.84 6.9 6.9 -4 5500 T154 89 7.13 6.42 7.84 6.9 6.9 -4 5500 T155 89 7.13 6.42 7.84 7.0 7.0 1 -2 500 Page 2 of 4 www.dallasfargo.com Checked By: F'L RGO CONSU-UrANTS. INC. 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD ** Revised Report ** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 6/9/2017 Stressed Date: 5/26/17-6/7/17 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T156 89 7.13 6.42 7.84 7.1 7.1 0 5500 T157 92 7.38 6.64 1 8.12 7.1 7.1 -3 5500 T158 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T159 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T160 92 7.38 6.64 8.12 1 7.0 7.0 -5 5500 T161 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T162 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T163 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T164 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T165 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T166 92 7.38 6.64 1 8.12 7.1 7.1 -3 5500 T167 92 7.38 6.64 8.12 7.0 7.0 -5 5500 T168 92 7.38 6.64 8.12 7.1 7.1 -3 5500 T169 92 7.38 6.64 8.12 1 7.0 7.0 -5 5500 T170 94 7.50 6.75 8.25 7.5 7.5 0 5500 T171 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T172 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T173 94 7.50 6.75 8.25 7.4 7.4 -2 5500 T174 94 7.50 6.75 8.25 7.3 7.3 -3 5500 T175 94 7.50 6.75 1 8.25 7.1 7.1 -5 5500 T176 94 7.50 6.75 8.25 7.1 7.1 -5 5500 T177 94 7.50 6.75 8.25 7.1 7.1 -5 5500 T178 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T179 1 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T180 35 2.63 2.37 2.89 2.5 2.5 -5 5500 T181 21 1.50 1 1.35 1.65 1.5 1.5 0 1 5500 T182 21 1.50 1.35 1.65 1.5 1 1.5 0 1 5500 Checked By Page 3 of 4 www.dallasfargo.com : I - p � FA RX;0 CONSULTANTS, INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD "Revised Report ** Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: 337463 Location: Floor Slab Building 14(Type 111) Pour 2 Report Date: 6/9/2017 Stressed Date: 5/26/17-6/7/17 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in %Final Elongation Pressure (PSI) T183 21 1.50 1.35 1.65 1.6 1.6 8 5500 T184 21 1.50 1.35 1.65 1.5 1.5 0 5500 T185 18 1.25 1.13 1.38 1.3 1.3 4 5500 T186 50 4.00 3.60 4.40 3.9 3.9 -3 5500 T187 50 4.00 3.604.40 1 3.8 3.8 -6 1 5500 T188 50 4.00 3.60 4.40 3.8 3.8 -6 5500 Revised report reflecting the elongations recorded on 6/7/17 for the * Repaired Cables. Page 4 of 4 www.dallasfargo.com Checked By: