Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 5/18/2017 (2)FARCO CONSULTANTS, INC. ti- 1, 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Report Date: 5/18/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/18/2017 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3543 Calibration Date: 4/3/2017 Gauge No.: R-129 Pump No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T1 21 1.50 1.35 1.65 1.5 1.5 0 5500 T2 21 1.50 1.35 1 1.65 1.5 1.5 0 5500 T3 35 2.63 2.37 2.89 2.6 2.6 -1 5500 T4 35 2.63 2.37 2.89 2.7 2.7 3 5500 T5 144 11.50 10.35 12.65 6.5 5.2 11.7 2 5500 T6 1 144 11.50 10.35 1 12.65 6.2 5.1 11.3 -2 5500 T7 144 11.50 10.35 12.65 6.8 5.1 11.9 3 5500 T8 144 11.50 10.35 12.65 6.8 5.0 11.8 3 5500 T9 144 11.50 10.35 12.65 6.6 5.0 11.6 1 5500 T10 144 11.50 10.35 12.65 6.4 5.3 11.7 2 5500 T11 144 11.50 10.35 1 12.65 6.5 5.2 11.7 2 5500 T12 142 11.38 10.24 12.52 6.5 5.1 11.6 2 5500 T13 142 11.38 10.24 12.52 6.6 5.1 11.7 3 5500 T14 142 11.38 10.24 12.52 6.5 5.2 11.7 3 5500 T15 142 11.38 10.24 1 12.52 6.7 5.3 12.0 5 5500 T16 142 11.38 10.24 12.52 6.9 5.2 12.1 6 5500 T17 142 11.38 10.24 12.52 6.8 5.1 11.9 5 5500 T18 142 11.38 10.24 12.52 6.8 5.1 11.9 5 5500 T19 142 11.38 10.24 1 12.52 6.4 5.2 11.6 2 5500 T20 142 11.38 10.24 12.52 6.9 5.3 12.2 7 5500 T21 1 142 11.38 10.24 12.52 6.6 5.2 11.8 4 5500 T22 142 11.38 10.24 12.52 6.8 5.1 11.9 5 5500 T23 142 11.38 10.24 12.52 6.8 5.0 11.8 4 5500 T24 142 11.38 10.24 12.52 6.8 5.0 11.8 4 5500 T25 139 11.13 10.02 12.24 6.4 5.2 11.6 4 5500 T26 1 139 11.13 10.02 12.24 6.3 5.2 11.5 3 5500 T27 1 139 11.13 10.02 12.24 6.3 5.0 11.3 2 5500 Page 1 of 4 www.dallasfargo.com Checked By.. ARoo coNaur.TANTS, INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: R-129 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 5/18/2017 Stressed Date: 5/18/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T28 139 11.13 10.02 12.24 6.3 5.1 11.4 2 5500 T29 1 139 11.13 10.02 1 12.24 6.4 5.0 11.4 2 5500 T30 139 11.13 10.02 12.24 6.5 5.0 11.5 3 5500 T31 139 11.13 10.02 12.24 6.4 4.9 11.3 2 5500 T32 139 11.13 10.02 12.24 6.4 5.0 11.4 2 5500 T33 139 11.13 10.02 1 12.24 6.5 5.0 11.5 3 5500 T34 140 11.13 10.02 12.24 6.5 5.1 11.6 4 5500 T35 140 11.13 10.02 12.24 6.5 5.0 11.5 1 3 5500 T36 30 2.25 2.03 2.48 2.3 2.3 2 5500 T37 30 2.25 2.03 1 2.48 2.2 2.2 -2 5500 T38 47 3.75 3.38 4.13 3.8 3.8 1 5500 T39 34 2.63 2.37 2.89 2.6 2.6 -1 5500 T40 73 5.88 5.29 6.46 6.1 6.1 4 5500 T41 73 5.88 5.29 6.46 6.0 6.0 2 5500 T42 71 5.63 5.07 6.19 5.8 5.8 3 5500 T43 71 5.63 5.07 6.19 5.9 5.9 5 5500 T44 71 5.63 5.07 1 6.19 5.8 5.8 3 5500 T45 71 5.63 5.07 6.19 5.8 5.8 3 5500 T46 71 5.63 5.07 6.19 5.8 5.8 3 5500 T47 74 6.00 5.40 6.60 6.2 6.2 3 5500 T48 74 6.00 5.40 6.60 6.2 6.2 3 5500 T49 74 6.00 5.40 6.60 6.1 6.1 2 5500 T50 68 5.38 4.84 5.92 5.5 5.5 2 5500 T51 68 5.38 4.84 1 5.92 5.5 5.5 2 5500 T52 68 5.38 4.84 5.92 5.4 5.4 0 5500 T53 68 5.38 4.84 5.92 1 5.5 1 5.5 2 1 5500 T54 68 1 5.38 4.84 5.92 1 5.5 1 5.5 2 1 5500 Page 2 of 4 www.dallasfargo.com Checked By: -2?z� F'ARGO CONSULTANTS. INC 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Report Date: 5/18/2017 Project Name: Grapevine Bluff Apartments Stressed Date: 5/18/2017 Grapevine, Texas Project No: M16-4962 Equipment ID: Ram No.: PSL -3543 Calibration Date: 4/3/2017 Gauge No.: R-129 Pump No.: 337463 Location: Floor Slab Building 14(Type III) Pour 2 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T55 68 1 5.38 4.84 5.92 5.5 5.5 2 5500 T56 72 5.75 5.18 1 6.33 5.8 5.8 1 5500 T57 72 5.75 5.18 6.33 5.7 5.7 -1 5500 T58 60 4.75 4.28 5.23 4.6 4.6 -3 5500 T59 60 4.75 4.28 5.23 4.8 4.8 1 5500 T60 60 4.75 4.28 1 5.23 4.8 4.8 1 5500 T61 69 5.50 4.95 6.05 5.6 5.6 2 5500 T62 69 5.50 4.95 6.05 5.8 5.8 5 5500 T63 68 5.38 4.84 5.92 5.4 5.4 0 5500 T64 68 5.38 4.84 5.92 5.4 5.4 0 5500 T65 68 5.38 4.84 5.92 5.6 5.6 4 5500 T66 71 5.63 5.07 6.19 5.6 5.6 -1 5500 T67 1 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T68 68 5.38 4.84 1 5.92 5.5 5.5 2 5500 T69 68 5.38 4.84 5.92 5.4 5.4 0 5500 T70 68 5.38 4.84 5.92 5.6 5.6 4 5500 T71 71 5.63 5.07 6.19 5.4 5.4 -4 5500 T72 71 5.63 5.07 1 6.19 5.4 5.4 -4 5500 T73 68 5.38 4.84 5.92 5.3 5.3 -1 5500 T74 68 5.38 4.84 5.92 5.3 5.3 -1 5500 T75 68 5.38 4.84 5.92 5.4 5.4 0 5500 T76 68 5.38 4.84 5.92 5.5 5.5 2 5500 T77 68 5.38 4.84 5.92 5.5 5.5 2 5500 T78 68 5.38 4.84 5.92 5.4 5.4 0 5500 T79 68 5.38 4.84 5.92 5.3 5.3 -1 5500 T80 68 5.38 1 4.84 5.92 1 5.4 1 5.4 0 5500 T81 1 71 5.63 1, 5.07 J 6.19 1 5.7 5.7 1 1 5500 Page 3 of 4 www.dallasfargo.com Checke w 2324 Fabens Rd., Dallas, TX 75229 Tel. (214) 352-4100 Fax. (214) 352-4811 FIELD POST TENSION STRESSING RECORD Client: JLB Partners, LP Project Name: Grapevine Bluff Apartments Grapevine, Texas Equipment ID: Ram No.: PSL -3543 Gauge No.: R-129 Location: Floor Slab Building 14(Type III) Pour 2 Report Date: 5/18/2017 Stressed Date: 5/18/2017 Project No: M16-4962 Calibration Date: 4/3/2017 Pump No.: 337463 Tolerance: ± 10% Cable ID Strand Mark Required Elongation (Inch) Minimum Elongation (Inch) Maximum Elongation (Inch) First Elongation (Inch) Second Elongation (Inch) Total Elongation (Inch) Variation in % Elongation Final Pressure (PSI) T82 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T83 68 5.38 4.84 5.92 5.5 5.5 2 5500 T84 68 5.38 4.84 5.92 5.2 5.2 -3 5500 T85 68 5.38 4.84 5.92 5.6 5.6 4 5500 T86 71 5.63 5.07 6.19 5.7 5.7 1 5500 T87 71 5.63 5.07 1 6.19 5.8 5.8 3 5500 T88 68 5.38 4.84 5.92 5.4 5.4 0 5500 T89 68 5.38 4.84 5.92 5.5 5.5 2 5500 T90 68 5.38 4.84 5.92 5.5 5.5 2 5500 T91 69 5.50 4.95 6.05 5.8 5.8 5 5500 T92 69 5.50 4.95 6.05 5.7 5.7 4 5500 T93 68 5.38 4.84 5.92 5.5 5.5 2 5500 T94 68 5.38 4.84 5.92 5.5 5.5 2 5500 T95 68 5.38 4.84 5.92 5.6 5.6 4 5500 T96 71 5.63 5.07 6.19 5.5 5.5 -2 5500 T97 71 5.63 5.07 6.19 5.7 5.7 1 5500 T98 68 5.38 4.84 1 5.92 5.5 5.5 2 5500 T99 68 5.38 4.84 5.92 5.5 5.5 2 5500 T100 68 5.38 4.84 5.92 5.4 5.4 0 5500 T101 68 5.38 4.84 5.92 5.5 5.5 2 5500 T102 68 5.38 4.84 5.92 5.6 5.6 4 5500 T189 100 8.00 7.20 8.80 8.0 8.0 0 5500 T190 1 100 8.00 7.20 8.80 8.1 8.1 1 5500 T191 100 8.00 7.20 8.80 1 8.2 8.2 2 5500 T192 18 1.25 1.13 1.38 1.2 1.2 -4 5500 T193 21 1.50 1.35 1.65 1.5 1.5 0 1 5500 T193A 21 1.50 1.35 1.65 1.5 1.5 0 5500 Page 4 of 4 www.dallasfargo.com A4 Checked By..- 1 ai RAM S/N: GAUGE: PUMP S/N: PSL -3543 R-129 337463. CALIBRATION STANDARD: Ready Cable ine. 4416 Keller Hicks Rd., Fort Worth, TX 76244 817.379.6553 Main 817.379.4007 Fax REPORT: EMILIO DATE: P-3500 STRAIN INDICATOR LOAD CELL 50 KIPS 4/3/2017 0148342 070202 Gauge Pressure (PSI) Load Cell Readings Average of Three Readings #1 #2 #3 1,000 6,460 6,600 6,720 6,593 2,000 12,250 12,280 12,310 12,280 3,000 18.640 18,662 18,694 18,665 4,000 24,7x0 24,738 24,760 24,736 5,000 30,400 30,440 30,465 30,435 6,000 36,610 1 36,650 1 36,680 36,647 40000 35000 w 30000 V 25000 LL 20000 ? 15000 N W 10000 5000 0 0 1000 2000 3000 4000 GAUGE PRESSURE (psi) 5000 6000 7000 For a stressing force of 33,050 pounds, a gauge pressure of 5,500 is required. y = 6.0229x + 479.16 TECH: 3. Hernandez 3R T8