Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/11/2017 (2)■ ■oRC0 2324 Pabens Rd. - DA1fa . Texas 75225 FARGO cONSUSXA WL'2a . INC Tol- 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page I of 1 Tested For: JLB Partners, LP Date Performed: 2/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 95 to 100 0 to +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 95 to 100 0 to +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. ILift Location No (pcf) Moisture Density 36 1ST PARKING AREA FIRE LANE GRID POINT Q-13 (SOUTH SITE GRID) 1 102 20.6 96.7 37 1ST PARKING AREA FIRE LANE GRID POINT Q-20 (SOUTH SITE GRID) 5 103.5 16.8 97.5 38 1ST PARKING AREA FIRE LANE GRID POINT T-14 (SOUTH SITE GRID) 5 104.7 20.4 98.7 39 1ST PARKING AREA FIRE LANE GRID POINT T-19 (SOUTH SITE GRID) 5 105.1 17.7 99.1 40 9TH WEST PARKING AREA GRID POINT H-6 (NORTH SITE GRID) 5 104.4 16.8 98.4 41 9TH WEST PARKING AREA GRID POINT 1A-5 (SOUTH SITE GRID) 5 103.9 18.6 97.9 42 9TH WEST PARKING AREA GRID POINT X-4 (SOUTH SITE GRID) 5 102 19.7 96.1 43 3RD WEST PARKING AREA GRID POINT Y-3 (SOUTH SITE GRID) 5 105.1 16.9 99.1 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo . on nt.1, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. ry Moore, CET Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com