REPORT OF FIELD COMPACTION Page 1 of I
Tested For: JLB Partners, LP Date Performed: 2/13/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS -5001 EZ
Probe Depth: 8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(01o) Max. DD (pc,) DD Range (%) MC Range
1 Light Gray SANDY CLAY 18.9
105.5 95 to 100 0 to +4
2 Light Gray CLAYEY SAND and gravel intermixed 10.2
116.4 95 to 100 0 to +4
5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8
106.1 95 to 100 0 to +4
Field Test Results
Test Elevation
Proctor DryDensity Percent
Percent
Location
No. /Lift
No (pcfi Moisture
Density
44 10TH WEST PARKING LOT AREA H-8 (NORTH SITE GRID)
5 100.8 19
95
45 10TH WEST PARKING LOT AREA G-8 (SOUTH SITE GRID)
5 105.5 17
99.4
46 10TH WEST PARKING LOT AREA X-9 (SOUTH SITE GRID)
5 1041 17.2
98.1
47 4TH WEST PARKING LOT AREA Y-11 (SOUTH SITE GRID)
5 101.6 16.8
95.8
48 SG FIRELANE GRID POINT N-13 (SOUTH SITE GRID)
2 110.8 14.2
95.2
49 SG FIRELANE GRID POINT N-18 (SOUTH SITE GRID)
2 111.5 14
95.8
50 SG FIRELANE GRID POINT Q-23 (SOUTH SITE GRID)
1 104.2 20.2
98.8
Source of Compaction Requirements: Geotechnical Report
Respectfully Submitted,
Fargo 5onsultauls, Inc.
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
* *REVISED REPORT*
Revised Report to reflect correct location for test #44-47
Test locations are referenced using an in-house system and are approximate.
G y Moore, CL'
aierials Testing Divisian
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotecbnical Engineering • Construction Materials Testing •Environmental Services
mvw. dallasfargo. com