HomeMy WebLinkAboutFargo Consultants, Inc. - 2/13/2017 (4)FIORG0
FARGO CO?: :i 11'3'A'• I:;_ r r 2 C ---
2324 Fabens Rd. • Dallas, Texas 75225
Tel. 214-352-4100 Fax. 214-352-4811
REPORT OF FIELD COMPACTION Page 1 of 1
Tested For: JLB Partners, LP Date Performed: 2/13/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max. DD (pcfi DD Range (%) MC Range
1 Light Gray SANDY CLAY 18.9
105.5 95 to 100 0 to +4
2 Light Gray CLAYEY SAND and gravel intermixed 10.2
116.4 95 to 100 0 to +4
5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8
106.1 95 to 100 0 to +4
Field Test Results
Test Elevation
Proctor DryDensity Percent
Percent
No. /Lift Location
No (Pcfi Moisture
Density
44 10TH WEST PARKING LOT AREA H-6 (NORTH SITE GRID)
5 100.8 19
95
45 10TH WEST PARKING LOT AREA 1A-5 (SOUTH SITE GRID)
5 105.5 17
99.4
46 10TH WEST PARKING LOT AREA X-4 (SOUTH SITE GRID)
5 104.1 17.2
98.1
47 4TH WEST PARKING LOT AREA Y-4 (SOUTH SITE GRID)
5 101.6 16.8
95.8
48 SG FIRELANE GRID POINT N-13 (SOUTH SITE GRID)
2 110.8 14.2
95.2
49 SG FIRELANE GRID POINT N-18 (SOUTH SITE GRID)
2 111.5 14
95.8
50 SG FIRELANE GRID POINT Q-23 (SOUTH SITE GRID)
1 104.2 20.2
98.8
Source of Compaction Requirements: Geotechnical Report
Respectfully Submitted,
Fargo 9011sulla ts, lite.
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Test locations are referenced using an in-house system and are approximate.
CET
��7oore,
aterials Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval, Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services