HomeMy WebLinkAboutFargo Consultants, Inc. - 5/24/2017 (4)-RRGV FARGO CONSULTANTS, INC. DAILY FIELD REPORT Client: JLB Partners, LP Project Name: Grapevine Bluffs Project Location: Grapevine, Texas Service(s) Provided: Structural Steel Observation Service(s) Performed By: BKH Inspection Services 2324 Fabens Rd. • D-Aas, Texas 75229 Tel 214-3524100 Fax 214-352-4811 Date Performed: 5/24/2017 FARGO Job No: M16-4962 Respectfully Submitted, Fargo Consultants, Inc. The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Serpices www.daBasfargo.com BKH INSPECTION SERVICES LLC. P.O Box 2472 Burleson, TX 76097 817-726-5456 bkhinspection(a.i mail.com www.bkhinspection.com 0a REPORT OF STRUCTURAL STEEL INSPECTION Client: Fargo Consultants, Inc. Project: Gra evine Bluffs- Grapevine, TX Services: Visual Inspection Drawings Utilized: Report No.: Project No.: Date of Service: Purchase Order No.: Page Contract Documents/ AWS D1.1. SS31388 M16-4962 05-24-2017 3493 1 of 1 Locations and Items Inspected: Building 1/ Leasing Area structural steel framing Levels 1 to 2. Discrepancies/Comments: I. Building 1/ Leasing Area structural steel framing welded and bolted connections Levels 1 to 2: A) The column to embed welded connections has numerous locations of overlap, rejectable undercut and undersize welds. -Non -Compliant B) The beam to column/ beam bolted connections has two locations of missing bolt holes in beams webs. - Non -Compliant CWI #97071361 Technician/ Inspectors Signature CWI #97041661 BICH Inspection Services, LLC. Limitations: The test results herein were prepared based upon the specific samples provided for testing We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control, this document is not a warranty or guaranty of the components inspected, it is intended to provide information as to the components inspected