FARGO CONSULTANTS, INC.
DAILY FIELD REPORT
Client: JLB Partners, LP
Project Name: Grapevine Bluffs
Project Location: Grapevine, Texas
Service(s) Provided:
Structural Steel Observation
Service(s) Performed By: BI'I Inspection Services
2324 Fabens Rd. • D-Aas, Texas 75229
Tel 214-352-4100 Fax 214-352-4811
Date Performed: 6/1/2017
FARGO Job No: M16-4962
Respectfully Submitted,
Fargo Consultants, Inc.
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on
data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www. dallasfargo. coni
BKH INSPECTION SERVICES, LLC.
P.O Box 2472 Burleson, Tx 76097
817-726-5456
bkhinsaection(i�utnail.com
www.bkh i nspection.com
REPORT OF
STRUCTURAL STEEL INSPECTION
Client: Fargo Consultants, Inc.
Project: Grapevine Bluffs- Gra 3c v i Ill:. TX
Services: Visual Inspection
Drawings Utilized:
Locations and Items Inspected:
Discrepancies/Comments:
Contract Documents.
Report No.:
Project No.:
Date of Service:
Purchase Order No.:
Page
Fitness Center structural steel j4rid lines 1-5 & A-E.
SS31534
M16-4962
06-01-2017
3502
1 of 1
I. The Fitness Center structural steel main frame bolted and welded connections at grid lines 1-5 & A-E with the
results as follows:
A) The beam bolted and welded connections appear to be acceptable per the RFI dated 05-25-2017 and the contract
documents. -Compliant
B) The beam to column cap plate welded connections appear to be acceptable per the contract documents. -Compliant
C) The column to embed plate welded connections appear to be acceptable, with the exception of the column at grid
lines 1 & D has been welded on 3 sides only. This item will need an RFI from Engineering. -Non -Compliant
II. BKH Inspection Services, LLC has received an RFI dated 05-25-2017 for the main frame bolted and welded
connections at Building 1 Leasing Office. This clears item I (B) on report #SS31388 dated 05-24-2017 and item II
on report #SS31527 dated 05 -25 -2017. -Compliant