Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/24/2017 (3)Q2324 Pabens Rd. • Dallas Texas 7522: arm r*� CONSULTANTS. YNc � Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page I of Tested For: JLB Partners, LP Date Performed: 2/24/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Mam DD (pc, fl DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 1042 3RD BLDG, PAD 17 GRID POINT K-9.4 (S. SITE GRID) 3 97.6 23.3 94.7 1043 4TH BLDG. PAD 17 RID POINT K-9.5 (S. SITE GRID) 3 99.4 23.6 96.4 1044 3RD BLDG. PAD 17 GRID POINT M.1-9 (S. SITE GRID) 3 97.4 23.5 94.5 1045 4TH BLDG. PAD 17 GRID POINT M5-9 (S. SITE GRID) 3 97.2 24.1 94.3 1046 5TH BLDG. PAD 17 GRID POINT K.6-9 (S. SITE GRID) 3 96.9 24.3 94 1047 6TH BLDG. PAD 17 GRID POINT K-9 (S. SITE GRID) 3 96.6 24 93.7 1048 5TH BLDG. PAD 17 GRID POINT M.4-9 (S. SITE GRID) 3 98.1 23.6 95.2 1049 6TH BLDG. PAD 17 GRID POINT M.6-9 (S. SITE GRID) 3 96.8 24,5 93.9 1050 7TH BLDG, PAD 17 GRID POINT K.1-9 (S. SITE GRID) 3 96.3 24.4 93.4 1051 8TH BLDG. PAD 17 GRID POINT K.7-9 (S. SITE GRID) 3 95.9 24.5 93 1052 7TH BLDG. PAD 17 GRID POINT M-9 (S. SITE GRID) 3 96.8 24.3 93.9 1053 8TH BLDG PAD 17 GRID POINT M.6-9 (S. SITE GRID) 3 97.5 23.6 94.6 1054 9TH BLDG. PAD 17 GRID POINT K.4-9 (S, SITE GRID) 1 99.2 23 94 1055 10TH BLDG. PAD 17 GRID POINT K.1-9 (S. SITE GRID) 1 98.9 22.9 93.7 1056 9TH BLDG, PAD 17 GRID POINT M.6-9 (S. SITE GRID) 3 96 23.9 93.1 1057 10TH BLDG. PAD 17 GRID POINT M.6-9 (S. SITE GRID) 1 99.3 23.1 94.1 1058 7TH BLDG. PAD 14 GRID POINT V-17.4 (N. SITE GRID) 5 99.9 21.7 94.2 1059 8TH BLDG. PAD 14 GRID POINT V.6-17.5 (N. SITE GRID) 1 100.2 23.7 95 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com F8700 2324 Fabens Rd. • Dnt6s Texas 75225 FaJrcae aoxsv:anerrs, Tiaq. 'rel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/24/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILft Location No. (pcf) Moisture Density 1060 7TH BLDG. PAD 14 GRID POINT U.1-17.1 (N. SITE GRID) 1 101.6 23 96.3 1061 8TH BLDG. PAD 14 GRID POINT U.717.7 (N. SITE GRID) 1 100.7 23.1 95.5 1062 9TH BLDG. PAD 14 GRID POINT V.6-17,6 (N. SITE GRID) 1 99.5 22.9 94.3 1063 10TH BLDG. PAD 14 GRID POINT V.4-17.1 (N. SITE GRID) 1 100 23.2 94.8 1064 9TH BLDG. PAD 14 GRID POINT U.9-17.7 (N SITE GRID) 1 99.4 22.9 94.2 1065 10TH BLDG. PAD 14 GRID POINT U.5-17.6 (N. SITE GRID) 1 98.7 23.1 93.6 1066 11TH BLDG. PAD 14 GRID POINT V.6-17.1 (N. SITE GRID) 3 99.8 23.4 96.8 1067 11TH BLDG. PAD 14 GRID POINT U-17.7 (N. SITE GRID) 1 99.2 22.9 94 1068 12TH BLDG. PAD 14 GRID POINT V.1-17.6 (N. SITE GRID) 3 97.6 23.7 94.7 1069 12TH BLDG. PAD 14 GRID POINT U.6-17.4 (N. SITE GRID) 1 98.4 23.4 93.3 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo onsultants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. /�Oze4w Ga Moore, CET Ga ials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Services www.dallasfarffo.com