HomeMy WebLinkAboutFargo Consultants, Inc. - 2/28/2017 (3)ff"',�L 7 0 -' A" FAUC3q CIai3-Es [3r7Abi �rfi,-INC. 2324 Fabens Rd. • Dallas, Texas 7522; Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I oft Tested For: JLB Partners, LP Date Performed: 2/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M 16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarFo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcJ) Moisture Density 1127 11TH BLDG. PAD 14 GRID POINT S.6-14.4 (N SITE GRID) 5 101.2 21.6 95.4 1128 12TH BLDG. PAD 14 GRID POINT S.4-14.5 (N. SITE GRID) 5 102.4 20.9 96.5 1129 13TH BLDG. PAD 14 GRID POINT S-14,1 (N. SITE GRID) 1 98.8 23 93.6 1130 11TH BLDG. PAD 14 GRID POINT T.6-14.7 (N. SITE GRID) 5 100.9 21.4 95.1 1131 12TH BLDG. PAD 14 GRID POINT T.7-14.6 (N. SITE GRID) 5 101.5 21 95.7 1132 13TH BLDG. PAD 14 GRID POINT T.6-14 (N. SITE GRID) 5 99.6 21.9 93.9 1133 SG BLDG PAD 14 GRID POINT R.1-12.1 (N. SITE GRID) 1 100.3 23.8 95.1 1134 SG BLDG. PAD 14 GRID POINT S.6-12.7 (N. SITE GRID) 1 99.2 23.1 94 1135 1ST BLDG. PAD 14 GRID POINT R-12.6 (N SITE GRID) 3 95.9 24.8 93 1136 2ND BLDG PAD 14 GRID POINT S.7-12.1 (N SITE GRID) 1 98.6 23.2 93.5 1137 1ST BLDG. PAD 14 GRID POINT S.6-12.9 (N. SITE GRID) 1 98.2 23.7 93.1 1138 2ND BLDG. PAD 14 GRID POINT S-12.4 (N SITE GRID) 3 96.7 24.5 93.8 1139 10TH BLDG. PAD 17 GRID POINT K1-7.1 (S. SITE GRID) 3 98.9 23.9 95.9 1140 11TH BLDG. PAD 17 GRID POINT K.7-7.2 (S. SITE GRID) 3 97.1 24.8 94.2 1141 10TH BLDG. PAD 17 GRID POINT M.6-7.7 (S. SITE GRID) 3 99.3 24.3 96.3 1142 11TH BLDG. PAD 17 GRID POINT M.5-7.6 (S. SITE GRID) 3 97.9 246 95 1143 12TH BLDG_ PAD 17 GRID POINT K1-7.4 (S. SITE GRID) 1 98.2 23.4 93.1 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarFo.com •_► ■ ■.00 2324 Fabens Rd. - Dallas Texas 7522: ■ FARG� correur.TArrxs. INC_ 1'cl. 214-352-4100 Fax. 214-352-4817 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo 17onsullants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. r Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,go.com REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pcf) Moisture Density 1144 13TH BLDG. PAD 17 GRID POINT K-7 (S. SITE GRID) 3 99 24.9 96 1145 12TH BLDG. PAD 17 GRID POINT M.6-7.6 (S. SITE GRID) 1 98.1 22.9 93 1146 13TH BLDG. PAD 17 GRID POINT M.6-7.7 IS, SITE GRID) 1 98.7 23.2 93.6 1147 SG BLDG PAD 17 GRID POINT 0.1-8.6 (S. SITE GRID) 3 96.1 24.9 93.2 1148 SG BLDG. PAD 17 GRID POINT 0,7-9.2 IS. SITE GRID) 3 95.9 25.1 93 1149 1ST BLDG. PAD 17 GRID POINT 0.1-8.7 (S. SITE GRID) 3 96.2 23.5 93.3 1150 2ND BLDG. PAD 17 GRID POINT 0,5-8,6 (S. SITE GRID) 1 98.4 23 93.3 1151 1ST BLDG. PAD 17 GRID POINT 0.6-9 (S. SITE GRID) 3 98.1 23.8 95.2 1152 2ND BLDG. PAD 17 GRID POINT 0-9.4 (S. SITE GRID) 1 98.9 22.9 93.7 1153 FG -2' BLDG. 1 GRADE BEAM GRID POINT U-25 (S. SITE GRID) 4 91.3 27.7 94.3 1154 FG -2' BLDG, 1 GRADE BEAM GRID POINT X-25 (S. SITE GRID) 4 93.1 26.4 96.2 1155 FG -2' BLDG. 1 GRADE BEAM GRID POINT W-26 (S. SITE GRID) 3 97 24.2 94.1 1156 FG -2' BLDG, 1 GRADE BEAM GRID POINT T-27 (S. SITE GRID) 4 94.9 26.4 98 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo 17onsullants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. r Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,go.com