Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 4/20/2017 (2)•.I� 2324 Pabens Rd. • Dallas, 'Texas 7522; yeAM= Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 2 Tested For: JLB Partners, LP Date Performed: 4/20/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,eo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pct Moisture Density 2109 FG -2' BLDG. 13 RETEST TEST NO.2107, REPT, DATE 4/19/2017 3 96.2 233 93.3 2110 FG -2' BLDG. 13 RETEST TEST NO2108, REPT. DATE 4/19/2017 3 95.9 23.4 93 2111 FG -2' BLDG. 13 GRADE BEAM GRID POINT G.5-20.5 (N. SITE GRID) 3 96.4 23.7 93.5 2112 FG -2' BLDG. 13 GRADE BEAM GRID POINT G.5-22.5 (N. SITE GRID) 5 99.3 22.2 93.6 2113 FG -2' BLDG. 13 GRADE BEAM GRID POINT M.5-23 (N. SITE GRID) 5 99.6 21.8 93.9 2114 SG BLDG. PAD 6 GRID POINT G.2-39 (N. SITE GRID) 4 90.3 27.2 93.3 2115 1ST BLDG. PAD 6 GRID POINT G 6-39 (N SITE GRID) 3 95.9 25.4 93 2116 2ND BLDG. PAD 6 GRID POINT G.4-39 (N. SITE GRID) 3 96.6 24.9 93.7 2117 3RD BLDG. PAD 6 GRID POINT G.6-39 (N. SITE GRID) 3 95.9 26 93 2118 4TH BLDG_ PAD 6 GRID POINT G.1-39,1 (N. SITE GRID) 3 97.2 24.9 94.3 2119 5TH BLDG. PAD 6 GRID POINT G.7-39.7 (N. SITE GRID) 1 99.8 22.9 94.6 2120 6TH BLDG. PAD 6 GRID POINT G.6-39.2 (N. SITE GRID) 1 98.9 23.8 93.7 2121 7TH BLDG. PAD 6 GRID POINT G.2-39.6 (N. SITE GRID) 1 99.6 23 94.4 2122 12TH BLDG. PAD 3 GRID POINT K.4-52 (S. SITE GRID) 4 91.8 26.4 94.8 2123 13TH BLDG PAD 3 GRID POINT K.6-52.1 (S. SITE GRID) 3 97.7 24.1 94.8 2124 12TH BLDG PAD 3 GRID POINT M.9-52.7 (S. SITE GRID) 4 91.2 26.7 94.2 2125 13TH BLDG. PAD 3 GRID POINT M.4-52.4 (S. SITE GRID) 3 97.3 23,6 94.4 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfar,eo.com ■� 0 2324 Fabens Rd. • Dallas, Texas 7522; FARGO xxvxxv. Tel. 214-352-4100 Fax. 214-352-4817 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 4/20/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches Test Elevation Proctor DryDensity Percent Percent (Lift Location No. (pcf) Moisture Density No. 2126 SG BLDG. PAD 3 GRID POINT 0.1-51.5 (S. SITE GRID) 3 96.6 24.7 93.7 2127 SG BLDG. PAD 3 GRID POINT 0-52..9 (S. SITE GRID) 3 96.1 25.1 93.2 2128 1ST BLDG. PAD 3 GRID POINT 0.6-51.1 (S. SITE GRID) 3 96.4 24.7 93.5 2129 2ND BLDG. PAD 3 GRID POINT 0.4-51.4 (S. SITE GRID) 3 96 253 93.1 2130 1ST BLDG. PAD 3 GRID POINT 0.6-52.4 (S. SITE GRID) 3 96.7 24.9 93.8 2131 2ND BLDG. PAD 3 GRID POINT 0.1-52.7 (S. SITE GRID) 3 95.9 25.6 93 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo nsit 1 ts, In C. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. C�`f Gary. oore, CET Maierials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services mww. dallasfarfo. com