HomeMy WebLinkAboutFargo Consultants, Inc. - 3/11/2017 (3)aa"C70 I11111110r.. 2324 Fabcns Rd. Dallas, "Texas 75225 PA"O CDtii'fITMANTS, INC, Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I of 2 Tested For: JLB Partners, LP Date Performed: 3/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas _ Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 6 Tannish Brown CLAYEY SAND - Select Fill 11.1 116.8 Min. 95 -2 to +2 7 Brown CLAYEY SAND - Select Fill 14.3 114 Min. 95 -2 to +2 8 Reddish Brown and Tan CLAYEY SAND 13 115 Min. 95 -2 to +2 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 1411 11 TH BLDG. PAD 11 GRID POINT U..5-34.1 (N. SITE GRID) 8 111.2 14.1 96.7 1412 12TH BLDG. PAD 11 GRID POINT U..2-34.3 (N. SITE GRID) 8 110.6 15 96.2 1413 13TH BLDG. PAD 11 GRID POINT U.6-34 (N. SITE GRID) 8 110.3 14.8 95.9 1414 FG BLDG. PAD 17 GRID POINT M.3--14 (S. SITE GRID) 7 112 13.9 98.2 1415 FG BLDG. PAD 17 GRID POINT L.4-11 (S. SITE GRID) 6 112.2 12.1 96.1 1416 FG BLDG. PAD 17 GRID POINT L.3-9 (S. SITE GRID) 7 109.1 12.5 95.7 1417 FG BLDG. PAD 17 GRID POINT M.1-8 (S. SITE GRID) 7 108.4 13.8 95.1 1418 FG BLDG. PAD 17 GRID POINT Q.5-9.2 (S. SITE GRID) 6 112.69 12.2 96.5 1419 FG BLDG. PAD 17 GRID POINT P.1-8.4 (S. SITE GRID) 6 1139 12.3 97.5 1420 FG BLDG. PAD 17 GRID POINT R.2-9.6 (S. SITE GRID) 7 109.2 12.6 95.8 1421 FG BLDG. PAD 17 GRID POINT S-8.1 (S. SITE GRID) 7 109.6 12.7 96.1 1422 FG BLDG. PAD 17 GRID POINT T.6-9.5 (S. SITE GRID) 7 111.2 15.9 97.5 1423 FG BLDG. PAD 17 GRID POINT U.5-8.6 (S. SITE GRID) 7 110.9 14.8 97.3 1424 8TH BLDG. PAD 19 GRID POINT N.4-37.4 (N. SITE GRID) 3 98.1 23.3 95.2 1425 9TH BLDG. PAD 19 GRID POINT N.6-37.9 (N. SITE GRID) 1 98.4 22.9 93.3 1426 10TH BLDG. PAD 19 GRID POINT N.1-37 (N. SITE GRID) 3 97 23.6 94.1 1427 11TH BLDG. PAD 19 GRID POINT N.8-37.4 (N_ SITE GRID) 3 96.2 24.1 93.3 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarFo.com 0 2324 Pabcns Rd. • Dal]as.'Fcxas 75225 aparusA ❑nxrsorrrnrrrs. INC. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 3/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (pcfi Moisture Density 1428 12TH BLDG. PAD 19 POINT N.6-37.6 IN. SITE GRID) 3 95.9 24.9 93 1429 13TH BLDG. PAD 19 GRID POINT N.4-37.7 (N. SITE GRID) 3 97.9 23.3 95 1430 FG BLDG. PAD 14 GRID POINT R.6-13.6 (N. SITE GRID) 7 111.8 13.9 98.1 1431 FG BLDG. PAD 14 GRID POINT S.6-12.1 (N. SITE GRID) 6 114 12.4 97.6 1432 FG BLDG. PAD 14 GRID POINT T.4-14.7 (N. SITE GRID) 6 114.3 12.1 97.9 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Far7A441 o Consultants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. �Wry Moore, CET terials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dalla.rfarfo.com