HomeMy WebLinkAboutFargo Consultants, Inc. - 3/13/2017 (3)Ll"M! o
FAR.00, 0MR10ITAN'r n. THO.
2324 Fabens Rd. • Dallas, "Texas 7522;
Tel. 214-352-4100 Fax. 214-352-4811
REPORT OF FIELD COMPACTION Page I of I
Tested For: JLB Partners, LP Date Performed: 3/13/2017
Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962
Grapevine, Texas
Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt
Test Mode: Direct Transmission Gauge Model: HS-5001EZ
Probe Depth: 8 Inches
Moisture -Density Relations
Proctor No. Material Description Opt. MC(%) Max. DD (pcfi DD Range (%) MC Range
1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4
3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4
4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4
Field Test Results
Test Elevation Proctor DryDensity Percent Percent
No. /Lift Location No (pct Moisture Density
1433 SG BLDG PAD 10 GRID POINT W.3-42.6 (N. SITE GRID) 4 92.9 26.4 96
1434 SG BLDG. PAD 10 GRID POINT V.1-43 8 (N_ SITE GRID) 4 93.4 27.1 96.5
1435 IST BLDG. PAD 10 GRID POINT W 4-42.5 (N. SITE GRID) 3 98.6 24.6 95.6
1436 2ND BLDG. PAD 10 GRID POINT W 3-42 (N SITE GRID) 3 97.1 238 94.2
1437 1ST BLDG. PAD 10 GRID POINT V 1-43.4 (N SITE GRID) 4 92.8 26.6 95.9
1438 2ND BLDG. PAD 10 GRID POINT V 6-43.6 (N SITE GRID) 3 97.4 23.5 94.5
1439 3RD BLDG. PAD 10 GRID POINT W 1-42 1 (N. SITE GRID) 1 99.3 23.4 94.1
1440 3RD BLDG. PAD 10 GRID POINT V.6-43.7 (N. SITE GRID) 3 96.6 23.8 93.7
1441 SG BLDG PAD 9 POINT U 1-45 5 (N SITE GRID) 3 97.2 23.3 94.3
1442 SG BLDG PAD 9 GRID POINT T 6-47 (N. SITE GRID) 3 96.8 23.7 93.9
Source of Compaction Requirements: Geotechnical Report Respectfully Submitted,
Fargo onsuftanis, Inc.
Test result with asterisk (*), if any, indicates non-compliance to provided guidelines.
Test locations are referenced using an in-house system and are approximate.
Ca Moore, CET
aterials Testing Division
The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based
on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition,
performance, etc. The use of our name and Lest results must receive our written approval. Reports must be reproduced in their entirety.
Geotechnical Engineering • Construction Materials Testing • Environmental Services