Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/13/2017 (3)Ll"M! o FAR.00, 0MR10ITAN'r n. THO. 2324 Fabens Rd. • Dallas, "Texas 7522; Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I of I Tested For: JLB Partners, LP Date Performed: 3/13/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max. DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pct Moisture Density 1433 SG BLDG PAD 10 GRID POINT W.3-42.6 (N. SITE GRID) 4 92.9 26.4 96 1434 SG BLDG. PAD 10 GRID POINT V.1-43 8 (N_ SITE GRID) 4 93.4 27.1 96.5 1435 IST BLDG. PAD 10 GRID POINT W 4-42.5 (N. SITE GRID) 3 98.6 24.6 95.6 1436 2ND BLDG. PAD 10 GRID POINT W 3-42 (N SITE GRID) 3 97.1 238 94.2 1437 1ST BLDG. PAD 10 GRID POINT V 1-43.4 (N SITE GRID) 4 92.8 26.6 95.9 1438 2ND BLDG. PAD 10 GRID POINT V 6-43.6 (N SITE GRID) 3 97.4 23.5 94.5 1439 3RD BLDG. PAD 10 GRID POINT W 1-42 1 (N. SITE GRID) 1 99.3 23.4 94.1 1440 3RD BLDG. PAD 10 GRID POINT V.6-43.7 (N. SITE GRID) 3 96.6 23.8 93.7 1441 SG BLDG PAD 9 POINT U 1-45 5 (N SITE GRID) 3 97.2 23.3 94.3 1442 SG BLDG PAD 9 GRID POINT T 6-47 (N. SITE GRID) 3 96.8 23.7 93.9 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo onsuftanis, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Ca Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and Lest results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services mww. dallasfarro. com