HomeMy WebLinkAboutFargo Consultants, Inc. - 4/21/2017 (4)4/7!2.120 VA ROO ❑❑Rsur.7AN Ta, ir4C. 2324 Pabcns Rd. , Dallas Texas 75221- Tel. 522;Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 4/21/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas .. Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches Test Elevation No. /Lift 2132 8TH 2133 9TH 2134 10TH 2135 3RD 2136 4TH 2137 3RD 2138 4TH 2139 5TH 2140 6TH 2141 5TH 2142 6TH 2143 7TH 2144 8TH 2145 7TH 2146 8TH Location BLDG. PAD 6 GRID POINT G.3-39.1 (N. SITE GRID) BLDG. PAD 6 GRID POINT G.1-39.8 (N. SITE GRID) BLDG. PAD 6 GRID POINT G.7-39.6 (N. SITE GRID) BLDG. PAD 3 GRID POINT 0-51.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-51.1 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.1-52 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.7-52.3 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0-51.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-51.1 (S. SITE GRID) BLDG, PAD 3 GRID POINT 0.1-52.6 (S. SITE GRID) BLDG, PAD 3 GRID POINT 0.6-52.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT O 1-51.1 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.7-51 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0-52.5 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-52.1 (S. SITE GRID) Proctor DryDensity No Moisture -Density Relations 1 98.9 Proctor No. Material Description Opt. MC(01o) Max DD (pcq DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 3 Field Test Results 3 97 Test Elevation No. /Lift 2132 8TH 2133 9TH 2134 10TH 2135 3RD 2136 4TH 2137 3RD 2138 4TH 2139 5TH 2140 6TH 2141 5TH 2142 6TH 2143 7TH 2144 8TH 2145 7TH 2146 8TH Location BLDG. PAD 6 GRID POINT G.3-39.1 (N. SITE GRID) BLDG. PAD 6 GRID POINT G.1-39.8 (N. SITE GRID) BLDG. PAD 6 GRID POINT G.7-39.6 (N. SITE GRID) BLDG. PAD 3 GRID POINT 0-51.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-51.1 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.1-52 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.7-52.3 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0-51.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-51.1 (S. SITE GRID) BLDG, PAD 3 GRID POINT 0.1-52.6 (S. SITE GRID) BLDG, PAD 3 GRID POINT 0.6-52.7 (S. SITE GRID) BLDG. PAD 3 GRID POINT O 1-51.1 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.7-51 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0-52.5 (S. SITE GRID) BLDG. PAD 3 GRID POINT 0.6-52.1 (S. SITE GRID) Proctor DryDensity No (pcf) 1 98.9 1 99.7 3 96.3 4 90.7 3 95.9 3 96.4 4 91.3 4 90.2 3 96 3 97.6 3 97 4 90 4 90.2 4 91.3 4 91.8 Percent Percent Moisture Density 23.4 93,7 23.1 94.5 23.9 93.4 26.9 93.7 25.1 93 24.7 93.5 26.5 94.3 26.8 93.2 25.5 93.1 25.1 94.7 24.6 94.1 27.9 93 27.3 93.2 26.7 94.3 27.2 94.8 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. "Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com PARR(] CONSXMTA;gTf..: Q. REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Fabens Rd. • Dallas 'Texas 7522: Tel. 214-352-4100 Fax. 214-352-4811 Page 2 of 2 Date Performed: 4/21/2017 Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Respectfully Submitted, Fargo Cions tants, Inc. ry Moore, CET Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com