Loading...
HomeMy WebLinkAboutTerracon - 8/15/2018 (4) RCONCRE1TbE COMPORESOSIVE STRENGTH TEST REPORT Irerracon Service Date: 08/15/18 2501 E Loop 820 N Report Date: 08/23/18 Fort Worth,TX 76118-6978 Task: 817-268-8600 Reg No:F-3272 Client Project Coury Hospitality Grapevine Main Phase 1 Attn:Mark Brooks 815 South Main Street 7134 S Yale, Ste 400 Grapevine,TX 76051 Tulsa,OK 74136 Project Number:95181011 Material Information Sample Information Specified Strength: 5,000 psi A 28 days Sample Date: 08/15/18 Sample Time: 0711 Sampled By: James Jimenez Mix ID: 9041 Weather Conditions: Cloudy Supplier: Argos Accumulative Yards: 9 Batch Size(cy): 9 Batch Time: 0635 Plant: 123 Placement Method: Pump Truck No.: 1736 Ticket No.: 12331648 Water Added Before(gal): 0 Water Added After(gal): 0 Field Test Data Sample Location: Garage,Level 3,Pour 1,Grid Line Test Result Specification P6/17 Slump(in): 9 6-9 Placement Location: Garage,Level 3,Pour 1,Grid Line Air Content(%): 6.0 3-6 P6-P10/16-17 Concrete Temp.(F): 95 50-95 Ambient Temp.(F): 77 Plastic Unit Wt.(pcf): 144.0 Yield(Cu.Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 1 A 4.00 12.57 08/16/18 08/18/18 3 64,880 5,160 5 1 B 4.00 12.57 08/16/18 08/22/18 7 74,530 5,930 4 1 C 4.00 12.57 08/16/18 09/12/18 28 1 D 4.00 12.57 08/16/18 09/12/18 28 1 E 4.00 12.57 08/16/18 09/12/18 28 1 F 08/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Terracon Rep.: James Jimenez Reported To: David with Manhattan Contractor: Report Distribution: See attached distribution list. Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000i,11-16-12,Rev.6 Page 1 of 2 RCONCRE1TbE COMPORESOSIVE STRENGTH TEST REPORT Irerracon Service Date: 08/15/18 2501 E Loop 820 N Report Date: 08/23/18 Fort Worth,TX 76118-6978 Task: 817-268-8600 Reg No:F-3272 Client Project Coury Hospitality Grapevine Main Phase 1 Attn:Mark Brooks 815 South Main Street 7134 S Yale, Ste 400 Grapevine,TX 76051 Tulsa,OK 74136 Project Number:95181011 Material Information Sample Information Specified Strength: 5,000 psi A 28 days Sample Date: 08/15/18 Sample Time: 0925 Sampled By: James Jimenez Mix ID: 9041 Weather Conditions: Cloudy Supplier: Argos Accumulative Yards: 107 Batch Size(cy): 9 Batch Time: 0857 Plant: 123 Placement Method: Pump Truck No.: 5106 Ticket No.: 12331662 Water Added Before(gal): 0 Water Added After(gal): 0 Field Test Data Sample Location: Garage,Level 3,Pour 1,Grid Line Test Result Specification P10/16 Slump(in): 9 6-9 Placement Location: Garage,Level 3,Pour 1,Grid Line Air Content(%): 7.8 * 3-6 P6-P10/16-17 Concrete Temp.(F): 95 50-95 Ambient Temp.(F): 79 Plastic Unit Wt.(pcf): 142.4 Yield(Cu.Yds.): *=Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 2 A 4.00 12.57 08/16/18 08/18/18 3 70,320 5,600 2 2 B 4.00 12.57 08/16/18 08/22/18 7 75,600 6,020 5 2 C 4.00 12.57 08/16/18 09/12/18 28 2 D 4.00 12.57 08/16/18 09/12/18 28 2 E 4.00 12.57 08/16/18 09/12/18 28 2 F 08/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Please note that set 2 had a high air content of 7.8%. Samples Made By: Terracon Services: Terracon Rep.: James Jimenez Reported To: David with Manhattan Contractor: Report Distribution: See attached distribution list. Reviewed By: J0 ILIP- Senior Project Manager Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t,11-16-12,Rev.6 Page 2 of 2 Distribution Page Report Number: 95181011.0406 Irerracon Service Date: 08/15/18 2501 E Loop 820 N Report Date: 08/23/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Distribution List (1)Coury Hospitality, Mark Brooks (1)AECC Inc, Lee Ledet (1)ArchiTexas, Michael Karnowski (1)City of Grapevine TX, Curtis A Bergthold (1)City of Grapevine TX, Paul M Lee (1)City of Grapevine TX, Scott Williams (1)City of Grapevine TX, sbatte@grapevinetexas.gov (1)Construction Management Group of Fair Oaks CA, Blake Cearley (1)JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Jaehyung Ahn (1) Manhattan Construction Co, Robert Montgomery (1)Walker Consultants, Martha M. Villanueva