HomeMy WebLinkAboutTerracon - 9/26/2018 (2)POST -TENSION OBSERVATIONS REPORT
Irerracon
Report Number: 95181011.0471
Service Date: 09/26/18 2501 E Loop 820 N
Report Date: 10/02/18 Fort Worth, TX 76118-6978
Task: Parking Garage 817-268-8600 Reg No: F-3272
Client Project
Coury Hospitality Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
7134 S Yale, Ste 400 Grapevine, TX 76051
Tulsa, OK 74136
Project Number: 95181011
PROJECT DATA
Drawings Utilized: PT 14 -PT 18, R04-1 A, R04-1 B, R04-1 G, R04-1 P, R04-1 Q, R04-1 K
Locations/Items Observed: Level 4 Pour 13 (P4.2 -P7.4/15-16)
Test Method: Visual Observation
REPORT OF OBSERVATION
ITEMS OBSERVED
CORRECT
INCORRECT
ITEMS OBSERVED
CORRECT
INCORRECT
ITEMS OBSERVED
CORRECT
INCORRECT
Placing DrawingsX
Approved
Length and Shape
X
Column Tie Spacing &
Type
Bar and Cable Size
X
Proper Placement
X
Stirrup Spacing & Type
X
Bar and Cable Grade
X
Properly Tied
X
Cables Properly Wrapped
Pending
Rebar and Cables Clean
X
Dowel Bars in Place
X
Mechanical Splices
Pending
Trash & Debris Removed
X
Proper Supports
X
Lapped Splices
X
Number of Bars and
Cables
X
Proper Cover/Clearance
X
Proper Drape of Cables
X
Discrepancies/Comments:
The cables U035, U036, U037, U038, U039, U040, U041, U042, U044, U046, U047, and U048 were too short to finish the span to the
pour strip and splices were added. The double strands alternated splices 4' 6" North and South of Beam at P6 and the single strands were
4' 6" South of P6. After the cables were spliced they had PVC pipe covering the area. Cables U043 and U045 were unaffected.
Services:
Terracon Rep.: Adam Wood
Reported To: David w/ Manhattan
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
�njupa
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
R940004, 07-01-12, Rev.0 Page 1 of 1
Distribution Page Irerracon
Report Number: 95181011.0471
Service Date: 09/26/18 2501 E Loop 820 N
Report Date: 10/02/18 Fort Worth, TX 76118-6978
Task: Parking Garage 817-268-8600
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) City of Grapevine TX, Paul M Lee
(1) City of Grapevine TX, Scott Williams
(1) City of Grapevine TX, sbatte@grapevinetexas.gov
(1) Construction Management Group of Fair Oaks CA, Blake Cearley
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Brad Scheckelhoff
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Jaehyung Ahn
(1) Manhattan Construction Co, Robert Montgomery
(1) Walker Consultants, Martha M. Villanueva