HomeMy WebLinkAboutTerracon - 10/1/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0476 Service Date: 10/01/18 2501 E Loop 820 N Report Date: 10/08/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9727 Supplier: Argos Batch Time: 1310 Plant: 123 Truck No.: 1736 Ticket No.: 1233306 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Set Specimen Avg Diam. Result Specification 7 5-7 5.8 3-6 91 83 146.4 No. ID (in) 1 A 4.00 1 B 4.00 1 C 4.00 1 D 4.00 1 E 0 Initial Cure: Outside 0 Comments: Samples Made By: Terracon Services: Sample Date: 10/01/18 Sample Time: Sampled By: Andrew Cloeter Weather Conditions: Clear Accumulative Yards: 8/8 Batch Size (cy): 8 Placement Method: Bucket & lift Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Column at P1/15.7 Placement Location: Columns at P1/15.7, P1/16, P4/18, 28 P5/18, P6/18, and P7/18 between the 12.57 4th and 5th Floors; also the Bumper 10/29/18 Wall at P3 -P4/18. Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 12.57 10/02/18 10/08/18 7 60,570 12.57 10/02/18 10/29/18 28 12.57 10/02/18 10/29/18 28 12.57 10/02/18 10/29/18 28 10/02/18 Hold Final Cure: Moist Room Terracon Rep.: Andrew Cloeter Reported To: David with Manhattan Contractor: Report Distribution: See attached distribution list. Compressive Strength Fracture Tested (psi) Type By 4,820 5 Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Paae Report Number: 95181011.0476 Service Date: 10/01/18 Report Date: 10/08/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Jaehyung Ahn (1) Manhattan Construction Co, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600