HomeMy WebLinkAboutESGN2016-4341 �A� IF JAN 2 7 2017
�
DATE OF ISSUANCE: )) �
PERMIT#: 1 (0 a T(
CD- 16- 4806
SIGN PERMIT APPLICATION
JOB ADDRESS: 1700 N Hwy 121 SUITE#
LOT: BLOCK: SUBDIVISION:
NAME OF BUSINESS: Fast Fuels
PHONE NUMBER:
SIGN CONTRACTOR (company name): Barnett Signs
(OR ELECTRICAL SIGN CONTRACTOR)STATE LICENSE REQUIRED FOR ELECTRICAL SIGN CONTRACTOR
CURRENT MAILING ADDRESS: 4250 Action Drive
CITY/STATE/ZIP: MesqulteTX. 75150 PHONE NUMBER: 972.681.8800
TYPE OF SIGN:
❑ FREE STANDING ❑WALL MOUNTED ❑BANNER ❑GRAND OPENING thru
® OTHER Fuel Canopy Signs- Qty (3) Logos and Qty 2 Channel letter sets
DESCRIPTION OF SIGN: Install illuminated logo
SIGN DIMENSIONS: (Logo) =4511 x 65.5" WALL DIMENSIONS: 4' x 37
ILLUMINATED?YES X NO REFACE? YES_ NO X ELEVATION: North Canopy Elevation 41 x 371
**In accordance with STATE LAW&CITY ORDINANCE_illuminated signs must be constructed,installed and wired by a State
Licensed Electrical Sign Contractor or a State Licensed Master Electrician. Signs may also be constructed by a fabricator
approved by a Nationally Recognized Testing Agency and labeled accordingly**
VALUATION OF SIGN: 1500.00
REQUIRED ATTACHMENTS:
1. A separate permit and 2 sets of drawings are required for each sign. For wall signs a separate permit application and
plans may be submitted for each elevation.
2. Pole or ground signs require a site plan drawn to scale showing location of the sign. Show dimensions and distances to
property lines. Pole sign structural drawings must be sealed by a State of Texas Registered Professional Engineer.
Monument and Ground sign applications must include footing detail.
3. Detailed,dimensioned plans of sign showing graphics.
4. Dimensioned building elevation showing sign or signs on building. Show dimensions of height & width of tenant space
and or building.
5. Plan Review Fee,65%of the permit fee is required when permit application is submitted. Balance due upon approval.
If any other signs are on the property,give the number and the types
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE
SAID WORK WILL BE DONE IN CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN �MENTS.
PRINT NAME: Jacob Capetillo SIGNATURE:
PH#: 972.681.8800 FAX#: EMAIL:
❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL
FOR OFFICE USE ONLY .I
FUNCTIONAL TYPE:CC I pre rn i Se PERMIT FEE:
STRUCTURAL TYPE:CGtyn Off( 5 i! Y1 PLAN REVIEW
APPROVED BY: a'A-- Q DATE: REMAINING FEE:
O:FORMISIGNAPP
6/JROOG-Rev9/p5$/U6,1I0],ll/09
Z�3 3�
SIGN, ELECTRICAL
iJlIt1I vII9Lj- Issue Date:January 27,2017
r1 8+ 1 A 6 ti PROJECT DESCRIPTION:Illuminated Canopy Signs(3)45"X 67.5'&(2)36"X 197.75""Fast Fuels"
PROJECT# (817)410-3010 www.mygov.us
ESGN-16-4341 Inspections Permits
City of Grapevine
P.O.Box 95104 LOCATION TENANT LEGAL
Grapevine,TX 76099 1700 State 121 Hwy. Fast Fuels Bethel Center Addition Elk 1
(817)410-3165 Voice Grapevine,TX 76051 Lot 1a
(817)410-3012 Fax
CONTRACTOR INFORMATION
Barnett Signs, Inc. +CONSTRUCTION TYPE VB
State ID#18034 "OCCUPANCY GROUP M
4250 Action Drive
Mesquite,TX 75150 "ZONING DISTRICT CC
(972)681-8800 Phone ""APPLICANT NAME Jacob Capetillo
(972)681-8824 Fax **APPLICANT PHONE NUMBER 972-681-8800
(214)533-5059 Mobile CERT OF APPROPRIATNESS N/A
County Tarrant
OWNER Illuminated/Non-Illuminated? Illuminated
Micromont Holdings 12 Llc Reface No
8140 Walnut Hill Ln Ste 400 Sign Dimensions 45"X 67.5'
Dallas,TX 75231 Type of Sign Being Installed ##
VALUATION 1500
AVAILABLE INSPECTIONS Wall Dimensions 4'X 37'
Sign Final(required)
Wall Elevation North Elevation
Zoning CC-Community Commercial
FEES TOTAL=$48.51
Sign Permit Fee(Plan Review) 65% $31.53
Sign Permit Fee(Remaining Fee)35% $ 16.98
PAYMENTS TOTAL=$48.51
Barnett Signs, Inc. (Barry Barnett)
Other on 11/14/2016 ($31.53)
Note:CC2347
Barnett Signs,Inc. (Barry Barnett)
Other on 0112712017 ($16.98)
Note:CC8339
NOTICES
ALL work must be done in compliance with the CITY OF GRAPEVINE SIGN
ORDINANCE,SECTION 60.
City of Grapevine CODE OF ORDINANCES.
And the 2005 NATIONAL ELECTRICAL CODE.
In accordance with STATE LAW&CITY ORDINANCE,Illuminated signs must
be constructed,installed and wired by a State Licensed Electrical Sign
MYGOVLS City of Grapevine I SIGN,ELECTRICAL I ESGN-164341 I Printed 01/27117 at 4:10 p.m. Page 1 of 3
Contractor or State Licensed Master Electrician.Signs may also be constructed
by a fabricator approved by a Nationally Recognized Testing Agency and
labeled accordingly.
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT OT THE BEST
OF MY KNOWLEDGE AND THAT THE SAID WORK WILL BE DONE IN
CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN
REQUIREMENTS.
II1` / 17
Signature Date
MYGOV.US City of Grapevine I SIGN,ELECTRICAL I ESGN-.16-4341 I Printed OV27/17 at 4:10 p.m. Page 2 of 3
t .
1.
O
all
O ,U Li Li
U oz o
zo U Q CC
.0�-.m LL Q O O N O F D d
Z_
Z o c�
LL za Y Zo
o a o aN W -j r o0
Q! 0 No¢ m Q m �� J -
N 0 r- W CH wa cn
�1 CJ c - G vaa c
L a Z � -cam.Z :,7 W
._ a
r Q °� cY a U�
r 0_
LLI
c _ J = w~ � -1 LL
O �,r W w 3: <CI
f i
~. U)
L• N .
O O /
LL z
5/ y (a C r
LL O � � ,j ► ..''Y
s � L
} ^�
Y 1 •! y
NOV 14 2016 OFFICE COPY
SiD -e. l;-1 !A-wy , `D lv P-`
Canoov Scone of Work: ,� W
-Remove all Shell Signage. LANDMARK
- Paint MPD Curbs Gray. ; N ASgn�Al_li_a_n�c_en_c.
•- wmxm� yroyernn,rbr w�
-Paint Bollards Red pms 485c. � � •, ,
- Install White ACM Fascia with Red Striping. CON TRACTOR Sf1F>, ,ALL FOR \ Phone:888.324.8687
- Install Illuminated Letters (2x)and Logos (3x). ■ { l RJS'E `! (: [let:
- Install New Pump Number Signs (12x). STORE-Paint Canopy Columns White(12x). ( r 71 Lf 1: € ® Fart Fuels Pc 3s23
+#*f,.+r 1700Texar121
f. (Impeufne,TX 76051
COtJTRACTOR RE _ RATION
\ ALL_ 7AE r ✓Pig: DN.
s ^"_ z FrLRMI I � h�i� :�N.
'.re•t
NB�i•III •e/alel Date:
SF^"-,RATE PLUMBING,MECHAN'CAL, 9/21/2016
ELECTRICAL AND SIGN PERM T S
PN o ro NI E-r R 1 c R ePo R't is R cQ t11 Zen p R5t 0 55' SHALL 8E REQUIRED
Drawn by:
S l ►=1fJAL. ccs
8"isionv
58' � 76'
i
Dmwing Number:
37' CANOPY N 37' 3523.1
48" Fascia
a sheet:
iof5
-fastfuels
T
165
0'td9e \�aR L Pe.^ ;-RUCTIQN
1O' QR ��)a), r� SHEE
tst sa" CAF C� REWITHT1 {i ILDING � �ti� ���F IN CONFi_ir;T
Existing Canopy z
A t9 a a THIS PUk }N
THE JOE A` -
Iii.-fastfugis. -r--- DATE: 12- 20. 2x)6
Canopy Pans&Guttering-White BUILDIN( i^'SPEr, 'N,
Pump Number Signs are Placed at Right Angles
Canopy Columns-White • RELEA E DOES ,
to Fuel Islands 9'.6"Above Ground Level
E EMENTS oj PULL UJr,„'.
(Measured From Base of Poles to Rounded Tops of ND
Signs) .A
ALL C ES n jj- c.
Bollards-Red(PMS 485c) — —
I
Minimum of One Windshield
Service Center/Trash Receptacle — .,,
Per Fuel Island
y 1,ban odpnai nnpuhnmed ft 1,
- - P. nal yad ma.rcu:un Wth nMynor
perwnvl ue In.oN•^<tlo�wnn:pnl.N
be xh—0 anyone—bide yow
Curbs-Gray snnn , w 4 rcw b<mnd, am,
np,cdwed,o nNWhd In any ruNOn.
LANDMARK
24" 24^ w aA7"sd»re� w.
Phone:888.324.8687
Ohl
Fas
Fart Fuels PC 3523
48" uels 3700 read;121
7.4astf
GrapeDtne,TX 76osf
15"
i
30"4-4 202" - ----
Date:
9/21/2016
67 1/2"
Drawn by:
1973/4" cis
Rewislons:
V]45!" II increased letters from 32-to 35'
36"
1' Drawing Number:
3523.2
2t SCI +
■ "Poppy Red"3630-143 Vinyl(PMS 485 C) sheet:
� "Intense Blue"3630-47 Vinyl(PMS 300 C) 2 of
Aluminum Pan Channel w/White Returns
&1"Blue(PMS 300 C)Trim Cap"fast" Approved:
Aluminum Pan Channel w/White Returns
&In Red(PMS 485 C)Trim Cap"fuels" 0 "Intense Blue"3650-47 Vinyl(PMS 300 C)
Acrylic Faces E Aluminum Pan Channel w/Blue PMS 300 Returns
&1"Blue(PMS 300)Trim Cap Notes:
❑ White LED Lighting,Internal Illumination Acrylic Face
- *p :- ❑ White LED Lighting, Internal Illumination
IlY Qr� r` PE1 INZ
RELEASED FG,- CNSTRDCTION
SHEET: OF.
RELEASE DOES NOT Al iTI-'?'!7E ANY WORK IN CONFLICT
WITH THE BUILDING Coi iE OR ZONING ORDINANCE.
THIS PLXP!T,` BE KEPT CN
�T/HE� JOLT AT ArL;L TIMES
DATE: IJ
,_3 6 Y: pl�"� This I.,n ntltlml unpublished Corwin(
—_—_—.—-- opened he she Ins.n1.mbMnM M your
i.—I need In m,lwueen vXh.end.
BUILDIN'- 7"SPFCTION DIVISION bison
RELEASE DOES NiJ' ;ePPL/T - CQNSI RI L^71x1';—rl be shown m emone outside your
mpneaeon,nor b R m be med,mweel,
I
EASEMENTS,, ; PIJaUC ;MIT OF lf,:-, rwrvdwee,drahlbredlnenr �
v
11.17.2011
TOMMY BELL
WANE,MPXa IPX VAP xaunPr
INS..Ill.a14X All. ..
PART ORIOIX 13 s
PART aCv A PIANOS.FWI1.T..GI.
0"...RE EC.
WITHOUT TH E WRITTEN PERMISSION OF
BIRNETI SILN&ING
PXOTU CONCEPTS ARE DRAWN TO
SCALE AS ACCURATELY AS
EXACT RLSIZE.T ALL NAP ROVAL$MAY
TO BE EASED ON EXACT SIGN SIZES.
A.No Securement Using
Appropriate Mounting Hardware
SIGNATURE
A
B.1/2"Flexible Conduit Whip to 120v Power
C. Blocking as Required per Location P TED NAME
D.20 amp 120v Circuits Required DATE
E. Disconnect Switch Required
a
F. 1/4"Weep Holes as Required
B CITY CF GRAPEVINE
RELEASED FOR CONSTRUCTIO
STATE OF TEXAS
SHEET: OF: 1 ELECTRICAL SIGN CONTRACTOR
ucensettleooA
RELEASE DOES NOT Ai_7TtinPIZE ANY WORK IN CONRICT
WITH THE BUILDING COPE OR ZONING ORDINANCE,
D F THIS PLAN TO BE KEPT ON
E THE JOB AT ALL TIMES
TYPICAL SECTION DETAIL DATE: 11 A0 •2016 BY:
NOT TO SCALE BUILDING INSPECTION DIVISION A961!'J�/G'TT
RELEASE DOES NO r APPLY 70 CONSTRUCTION IN J.���7N I
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
C.A140PI -- -CHANGES MUST BE APPHOVLU-
WAtL SIGN ATTACHMENT DRAWING 4250 ACTION DRIVE
MESQUITE.TEXAS 75150
972.661.8800 PHONE
972.661.8824 FAX