Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SFADD2017-1166
rA ! % 9 2011 e IV1~� DATE OF ISSUANCE: 2017, C-Ls\\eC 1 T' 21'17 Ct :O o At». PERMIT#: BUILDING PERMIT APPLICATION (PLEASE PRINT T LEGjI�BLY-COMPLETE ENTIRE FORM) JOB ADDRESS: 1704 6;we'/5,de 'rr SUITE# LOT: 75R _BLOCK: SUBDIVISION: �/�) BUILDING CONTRACTOR(company name): &i/&P /•n(�J/�,�P✓ (1-5 k'n 1-k'n °S' '7'— C \� CURRENT MAILING ADDRES/S: P©• &,X 732 73 561,4/IQ ke 7Y d• CITY/STATE/ZIP: _5EIU-i—A t' PH:# T"1_q25_ "Fax# —� PROPERTY OWNER: p`tM CURRENT MAILING ADDRESS: CITY/STATE/ZIP: PHONE NUMBER: PROJECT VALUE: $ / ® FIRE SPRINKLERED? YES NO WHAT TRADES WILL BE NEEDED?(Check ones that apply)ELECTRIC PLUMBING MECHANICAL / DESCRIPTION OF WORK TO BE DONE: rp�1?i Vw 0191 �cl� 7 1 �7fl USE OF BUILDING OR STRUCTURE: in .S i&-n Na 1 NAME OF BUSINESS: � r L6 Total Square Footage under roof: Square Footage of alteration/addition: DC/ .r 1 hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department(required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 &2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS,ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY E CITY,AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH RO AL FRO T AP ROPRIATE STATE AND OR FEDERAL AGEN (S). PRINT NAME: tl �((, / SIGNATURE r CHECK BOX IF PREFERRED TO BE CO TACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: \/R Permit Valuation: $ j j O1 ODD Setbacks Approval to Issue Occupancy Group: R• Fire Sprinkler: YES NNO — Front: 3p 1 Electrical L— Division: Building Depth: Left: I Plumbing L� Zoning: R 'J •s Building Width: Rear: 2 51 Mechanical 1. Occupancy Load: Ri ht: ARIA - jc Plan Review Approval: Date: 4 -11- 17 Building Permit Fee: Site Plan Approval: Date: Plan Review Fee: Fire Department: Date: Lot Drainage Fee: Public Works Department: Date: Sewer Availability Rate: Health Department: Date: Water Availability Rate: Approved for Permit: Date: 1. 20 .17 Total Fees: Lot Drainage Submitted: R Approved: '( 20.17 —Total Due: ' ` P.0.BOX 95104,GPPPEVINE,TX 7099(817)410-3165 OFORM51G5PERMITAPPLIGATION5110P-, 406R/W.11N9,4111 CITY OF GRAPEVINE TEMPORARY ELECTRIC RELEASE Temporary electricity has been requested for the purpose of construction, remodeling, addition or improvement to the following described property. It is understood that this release in no wa authorizes occupancy of the building. It is further understood that this temporary release is for a thirty (30) day maximum time period and the undersigned releases all claims that may occur through accidents or spoilage of any type resulting from said electric power being turned off at the end of the thirty (30) day maximum time period. ADDRESS LOCATION OF TEMPORARY ELECTRIC RELEASE: ADDRESS: O701 PERMIT NUMBER: / 7 CONTRACTOR INFORMATION NAME OF APPLICANT: r/ /J/c / t�i✓S /�,� l �s ADDRESS OF APPLICANT: P,& 13 o x Q3 2 )j CITY, STATE, ZIP: TELEPHONE NUMBER: INSPECTIONS FOR TEMPORARY POWER MUST BE REQUESTED AT (817) 410.3010 SIGN TURE• PR DATE: BUILDING OFFICIAL DATE: oAformlE-tem 10/10/00 Re ised• 110/0 VINE. Iss_ue Date: " ° CITY OF GRAPEVINE (CIRCLE ONE) MECHANICAL - ELECTRICAL - PLUMBING - IRRIGATION - FUEL GAS PERMIT APPLICATION PLEASE PRINT LEGIBLY-COMPLETE ENTIRE FORM PERMIT# .�JJvI l ®®" - BLDG.PERMIT#•� _ i I DATE: JOB ADDRESS: (� / SUITE# DESCRIPTION OF WORK: Ot/'G PROPERTY OWNER: CONTRACTING COMPANY: ADDRESS: ADDRESS: \ CITY/STATE/ZIP: CITYISTATEIZIP: n / ,- t}ry PHONE NUMBER: PHONE NUMBER: TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES AMOUNT DUE SQ FT EACH TRADE I. R-3 1 - 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION & 1,501 - 1,750 $ 76.48 ADDITIONS(PER UNIT) 1,751 - 2,000 $ 83.13 2,001 - 2,250 $ 89.78 TOTAL SQ. FOOT UNDER 2,251 - 3,000 $ 96.43 ROOF p 3,001 - 3,500 $ 103.08 �r +900 3,501 - 4,000 $ 109.73 $ 4,001 + $ 120.37 EACH TRADE II. A, E, I, R-1 1 - 500 $ 37.00 HOTELS,APARTMENTS, 501 -100,000 $ 17.50+,035 PER DRINKINGIDINING, 100,001 -500,000 $ 3,500.00+.03 SQUARE EDUCATIONAL,ASSEMBLY, 500,001 + $15,000.00+.02 FOOT $ INSTITUTIONAL EACHTRADE III. B, F, H, M, S, U OFFICE, RETAIL, WHOLESALE, 1 - 500 $ 37.00 GARAGES, FACTORIES, 501 - 50,000 $ 32.00+ .01 PER WORKSHOPS, SERVICE 50,001- 100,000 $ 182.00+ .007 SQUARE STATIONS, WAREHOUSE 100,001+ $ 582.00+ .003 f FOOT $ CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH-OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+ .009 50,001-100,000 $ 127.00+ .007 PER $ 100,001-500,000 $ 327.00+ .005 DOLLAR $ 500,001+ $ 1,327.00+ .003 IVALUATION V. MISCELLANEOUS EACH TRADE IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC - $ 37.00 $ C:\Users\sbatteVppDa�\Local\Microwft\Windows\Temporary Internet Files\Content Outlook\G86F6GQF\MEP APPLICATION 4-11.doc PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM)...............................................$42.00/HOUR" REINSPECTIONFEES................................................ .......................................................... ..... $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED........................................................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES,ADDITIONS, OR REVISIONS TO APPROVEDPLANS.......................................................................................................................$42.00/HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25%OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS,OR BOTH.........ACTUAL COSTS** I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND I OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERG CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. SIGNATURE OF CONTRACTOR-eR AUTHORIZED AGENT PRINTED NAME (O.(z HOM E.OWNER FOR HOMEOWNERS PERMITS) / *OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. **ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. Development Services Department,Building Inspections The City of Grapevine*P.O.Box 95104 SIP Grapevine,Texas 76099 *(817)410-3165 Fax(8171)410-3012 *www.grapevinetexas.gov C:\Users\sba0e\AppData\Local\Microsoft\Windows\Temporary Internet Files\ContenLO,tlook\G80EeGOF\MEP APPLICATION 4-11 doc at T E V s CITY OF GRAPEVINE '� � �Ike (CIRCLE ONE) MECHANICAL 3LECTRICAL - PLUMBING - IRRIGATION - FUEL GAS PERMIT APPLICATION PLEASE PRINT LEGIBLY-COMPLETE ENTIRE FORM) PERMIT# . 0 q BLDG.PERMIT#i. _ I l DATE: JOB ADDRESS: 170 I SUITE# DESCRIPTION OF WORK: / PROPERTY OWNER: ,M2t2.. 1 \ , CONTRACTING COMPANY: Q�^-{!(S} f So!k4,riv3 ADDRESS: ADDRESS: � v � � CITY/STATE/ZIP: CITY/STATE/ZIP:o'tfK I U,0-7 If PHONE NUMBER: I PHONE NUMBER: 3117- L{e5 . TYPE OF OCCUPANCY BUILDING AREA SO FT PERMIT FEES AMOUNT DUE EACH TRADE I. R-3 1 - 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION& 1,501 - 1,750 $ 76.48 ADDITIONS(PER UNIT) 1,751 - 2,000 $ 83.13 2,001 - 2,250 $ 89.78 TOTAL SQ. FOOT UNDER 2,251 - 3,000 $ 96.43 ROOF 3,001 - 3,500 $ 103.08 UQ 3,501 - 4,000 $ 109.73 $ y 4,001 + $ 120.37 EACH TRADE 11. A, E, I, R-1 1 - 500 $ 37.00 (✓ t HOTELS,APARTMENTS, 501 - 100,000 $ 17.50+.035 PER DRINKING/DINING, 100,001 -500,000 $ 3,500.00+,03 SQUARE EDUCATIONAL,ASSEMBLY, 500,001 + $15,000.00+.02 FOOT $ INSTITUTIONAL EACH TRADE III. B, F, H, M, S, U OFFICE, RETAIL, WHOLESALE, 1 - 500 $ 37.00 GARAGES, FACTORIES, 501 - 50,000 $ 32.00+ .01 PER WORKSHOPS, SERVICE 50,001- 100,000 $ 182.00+ .007 SQUARE STATIONS, WAREHOUSE 100,001+ $ 582.00+ .003 f FOOT $ CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH-OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+ .009 50,001- 100,000 $ 127.00+ .007 PER $ 100,001-500,000 $ 327.00+ .005 DOLLAR $ 500,001+ $ 1,327.00+ .003 1V ALUATION V. MISCELLANEOUS EACH TRADE IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 $ OAFORMSWS APPLICATIONS-FEESWEP APPLICATION 4-11.doc r PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS(2HR MINIMUM)...---...................................$42.00/HOUR* REINSPECTION FEES.................................................................................................................. $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED........................................................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES,ADDITIONS, OR REVISIONS TO APPROVEDPLANS.......................................................................................................................$42.00/HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH.........ACTUAL COSTS** I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VE IC TION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST, SIGNATURE ONTRACTOR OR AUTHORIZED AGENT PRINTED NAME (OR HOMEOWIrr RR FOR HOMEOWNERS PERMITS) S PHONE#: ) /'O�� Gat- EMAIL: *OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. **ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. Development Services Department,Building Inspections The City of Grapevine*P.O.Box 95104*Grapevine,Texas 76099 *(817)410-3165 Fax(817)410-3012 *www.grapevinetexas.gov � T. nt x 1 / [` C ' rn t �> S, I ; 1. EROSION CONTROL REQUIRED BEFORE CONSTRUCTION STARTS. 2. NO CONSTRUCTION, FILLING, CUTTING, OR GRADE CHANGE IN EASEMENT WITHOUT PRIOR APPROVAL. 3. MAINTAIN CURRENT DRAINAGE PATTERN. 4. GRASS/EROSION CONTROL REQUIRED BEFORE FINAL. A Texas Commission on Environmental Quality Customer Service Inspection Certificate Name of PWS: City of Grapevine PWS ID #: 2200013 Location of Service: 17041 /)k, P 1 —S&7 Reason for Inspection: New construction .............................................................................. ❑ Existing service where contaminant hazards are suspected............ ❑ Major renovation or expansion of distribution facilities.................... X I f}IZ2y 6R--1 , upon inspection of the private water distribution facilities connected to the aforementioned public water supply do hereby certify that, to the best of my knowledge: Compliance Non-Compliance y (1) No direct connection between the public drinking water supply J� ❑ and a potential source of contamination exists. Potential sources of contamination are isolated from the public water system by an air gap or an appropriate backflow prevention assembly in accordance with Commission regulations. (2) No cross-connection between the public drinking water supply and ❑ a private water system exists. Where an actual air gap is not maintained between the public water supply and a private water supply, an approved reduced pressure principle backflow prevention assembly is properly installed and a service agreement exists for annual inspection and testing by a certified backflow prevention assembly tester. (3) No connection exists which would allow the return of water used ❑ for condensing, cooling or industrial processes back to the public water supply. (4) No pipe or pipe fitting which contains more than 8.0% lead exists ❑ in private water distribution facilities installed on or after July 1, 1988 and prior to January 4, 2014. (5) Plumbing installed after January 4, 2014 bears the expected �f ❑ labeling indicating <_0-25% lead content. If not properly labeled, �T please provide written comment. (6) No solder or flux which contains more than 0.2% lead exists in f ❑ private water distribution facilities installed on or after July 1, 1988. 1 further certify that the following materials were used in the installation of the private water distribution facilities: Service lines; Lead ❑ Copper k PVC ❑ Other Solder; Lead ❑ Lead Free Solvent Weld ❑ Other 1 recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information I have provided. Remarks: I Existing plumbing may have been installed without permits/ inspections and therefore cannot be verified. It is impossible to verify compliance of existing plumbing which is covered by building construction. Signature of Inspector: License Number: ZPlumbing=Ins Title: ns ec Type of License: ctor Date: 7 O;Felmi\7iEOQ06"\O 47-17 Keith R. Marsh, P. E. TBPE No. F-1037 (Foundation Engineering) 2201 Oak Knoll Court Colleyville, TX 76034-4488 Mobile 817 925 7528 < March 22, 2017 Mr Bailey Draper Bailey Draper Custom Homes, Inc. P. O. Box 93273 Southlake, TX 76092 Dear Mr Draper: This is to certify that I designed the foundation additions for the house at 1704 Silverside Drive, Grapevine, Texas . These foundation additions were designed using the analysis methods outlined in "Designing Floor Slabs on Grade", Second Edition, published by The Aberdeen Group, distributed by the American Concrete Institute (ACI) and using the results of test data provided by the Post Tensioning Institute (PIT) . These methods can be applied to the design of post tensioned and conventional rebar reinforced foundations . The methods are compatible with the structural integrity design requirements and guidelines of the latest versions of the 2012 and 2015 editions of the International Residential Code (IRC) . The soil data for this building site were estimated. Please call me if you have any questions regarding this report . There are no insignificant or inappropriate questions on this subject . Sincerely, 4iftl�N aYs�, F . R eport No. bdral7bld.wpd THIS REPORT CONSISTS OF ONE PAGE .r+•'E OF 7. pK TF-�9�aa r r*; PB :* '•,* a 2017 ! KEITH R �HRSH ; MAR 2 9 Page -1- �,� ....... ................s C�J( REScheck Software Version 4.6.3 Compliance Certificate Project HOLT RENTAL PROPERTY Energy Code: 2012 IECC Location: Grapevine, Texas Construction Type: Single-family Project Type: Addition Orientation: Bldg. faces 270 deg. from North Climate Zone: 3 (2683 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 1704 SILVERSIDE DR. GRAPEVINE,TX Compliance: Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum JA: 570 Your UA: 570 Maximum SHGC: 0.25 Your SHGC 0.25 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. Ceiling 1: Flat Ceiling or Scissor Truss 2,607 30.0 2.8 0.032 83 Wall 1: Wood Frame,24"o .c. 432 13.0 2.2 0.067 20 Orientation: Front Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 108 0.300 32 SHGC: 0.25 Orientation: Front Door 5: Glass 23 0.290 7 SHGC: 0.25 Orientation: Front Wall 2:Wood Frame,24"o .c. 576 13.0 2.2 0.067 38 Orientation: Right side Window 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 6 0.300 2 SHGC: 0.25 Orientation: Right side Wall 3:Wood Frame,24"o .c. 432 13.0 2.2 0.067 16 Orientation: Back Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 36 0.300 11 SHGC: 0.25 Orientation: Back Door 4: Solid 164 0.290 48 Orientation: Back Wall 4: Wood Frame,24"o .c. 576 13.0 2.2 0.067 34 Orientation: Left side Window 5: Vinyl/Fiberglass Frame:Double Pane with Low-E 34 0.300 10 SHGC: 0.25 Orientation: Left side Door 6: Solid 40 0.290 12 Orientation: Left side Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and SettingsVoel\Desktop\RES-CHECK\1671-MOLT RENTAL PROPERTY Pagel of 9 (1704 SILVERSIDE).rck JUN 19 2017 rI — lit, co Assembly Gross Area Cavity Cont. Perimeter Floor 1: Slab-On-Grade:Unheated 247 0.0 1.042 257 Insulation depth:0.0' Compliance Statement., The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and Settings\Joel\Desktop\RES-CHECK\1671-HOLT RENTAL PROPERTY Page 2 of 9 (1704 SILVERSIDE).rck REScheck Software Version 4.6.3 Inspection Checklist Energy Code: 2012 IECC Requirements: 3.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? CommentslAssumptions & Req.ID 103.1, (Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the 0� ',building envelope. ❑Not Observable ❑Not Applicable 103.1, '.Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable [PR3]1 ;lighting and mechanical systems. Systems serving multiple ❑Not Applicable j dwelling units must demonstrate compliance with the IECC 'Commercial Provisions. 302 1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr_ Btu/hr approved by the code official. ❑Not Applicable j Additional Comments/Assumptions: 111 High Impact(Tier 1) '2 IMedium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and Settings�oel\Desktop\RES-CHECK\1671-HOLT RENTAL PROPERTY Page 3 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Foundation Inspection & Req.ID Value Value Complies? Comments/Assumptions 402.1.1 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FOl]1 .❑ Unheated I,❑ Unheated El Does Not table for values. 0 ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 303.2, Slab edge insulation installed per ❑Complies 402.2.9 manufacturer's instructions. ❑Does Not [F02]1 ❑Not Observable ,d ❑Not Applicable 402.1.1 Slab edge insulation _ft ft ❑Complies See the Envelope Assemblies [F031' .depth/length. ❑Does Not table for values. 0 ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F011]2 to protect exposed exterior ❑Does Not 0 insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable j 403.8 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and Settings�oel\Desktop\RES-CHECK\1671-HOLT RENTAL PROPERTY Page 4 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U-- U-- ❑Complies ISee the Enve lope Assemblies 402.3.4 ❑Does Not ;table for values. ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-- U-- ❑Complies ;See the Envelope Assemblies 402.3.1, average). ❑Does Not ;table for values. 402.3.3, 402.3.6, :❑Not Observable 402.5 ❑Not Applicable [FR2]1 402.1.1, Glazing SHGC value(area- SHGQ— SHGC: ❑Complies See the Envelope Assemblies 402.3.2, weighted average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR3]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not u with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable -- - - ...._-------- ---------- --- 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR2311 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not O, AAMA/WDMA/CSA 101/i.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not U) and labeled to indicate s2.0 cfm ❑Not Observable leakage at 75 Pa. _ ❑Not Applicable 403.2.1 Supply ducts in attics are R- R-- ❑Complies [FR12]1 :insulated to ?R-8.All other ducts R- R- !.❑Does Not 0 ;in unconditioned spaces or — I outside the building envelope are ❑Nat Observable insulated to >_11-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 :air handlers,and filter boxes are ❑Does Not U, :sealed. ❑Not Observable ❑Not Applicable j 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable _ ❑Not Applicable 403.3 HVAC piping conveying fluids R-- R- ❑Complies [FR17]2 above 105 OF or chilled fluids ❑Does Not below 55 °F are insulated to_>R- j 3. ❑Not Observable ❑Not Applicable j 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable j 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and Settings\oel\Desktop\RES-CHECK\1671-HOLT RENTAL PROPERTY Page 5 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.4.2 Hot water pipes are insulated to R-_ R-_ ;❑Complies [FR18]2 aR-3. -❑Does Not J ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and Settings�oel\Desktop\RES-CHECK\1671-HOLT RENTAL PROPERTY Page 6 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13)2 or the installed R-values ❑Does Not M) provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/z of the ❑ Wood !❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass !❑ Mass ❑Not Observable [IN3)1 -exterior,the exterior insulation -requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4)1 manufacturer's instructions. ❑Does Not Uch ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: C:\Documents and SettingsVoel\Desktop\RES-CH ECK\1671-HOLT RENTAL PROPERTY Page 7 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, :Ceiling insulation R-value. R- R- '..❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not :table for values. 402.2.2, E] Steel E] Steel ❑ 402.2.6 Not Observable [Fill' ❑Not Applicable 303.1.1.1,•Ceiling insulation installed per ❑Complies 303.2 'manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 14� 300 ft'. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122)2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable j 402.2.4 Attic access hatch and door R R-_ ❑Complies [FI311 !insulation all-value of the '.❑Does Not I adjacent assembly. ❑Not Observable I ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ;E ICO mplies [FI17]1 :ach in Climate Zones 1-2, and j❑Does Not ,Q j<=3 ach in Climate Zones 3-8. j❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 I❑Complies [FI411 :cfm/100 ft2 across the system or ft2 ! ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable 'handier@ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable j occur during Framing Inspection. 403.2.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable j 403.1.1 Programmable thermostats ❑Complies [F1912 installed on forced air furnaces. ❑Does Not u ❑Not Observable [-]Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [Fl 10]2 on heat pumps. ❑Does Not d' ❑Not Observable ❑Not Applicable j 403.4.1 Circulating service hot water ❑Complies [Flll]z systems have automatic or ❑Does Not d, accessible manual controls. ❑Not Observable ❑Not Applicable j 403.5.1 All mechanical ventilation system ❑Complies [FI2512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable _ ❑Not Applicable 404.1 175%of lamps in permanent ❑Complies [FI611 (fixtures or 75%of permanent ❑Does Not ;fixtures have high efficacy lamps. :Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: CADocuments and SettingsUoel\Desktop\RES-CH ECMI671-HOLT RENTAL PROPERTY Page 8 of 9 (1704 SILVERSIDE).rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _ 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. [!]Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies IFI712 ❑Does Not 14' ❑Nat Observable ❑Not Applicable j 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not b, systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: HOLT RENTAL PROPERTY Report date: 03/27/17 Data filename: CADocuments and Settings\oel\Desktop\RES-CH ECK\1671-HOLT RENTAL PROPERTY Page 9 of 9 (1704 SILVERSIDE).rck fz2012 IECC Energy Efficiency Certificate Above-Grade Wall 15.15 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 32.85 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 0.25 Door 0.29 0.25 Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments City of Grapevine Building Inspection Department Plan Review Comments P.O. Box 95104 Phone: (817) 410-3129 Grapevine, Texas 76051 Fax: (817) 410-3536 NAME OF PROJECT: HOLT RENTAL PROPERTY ADDRESS: 1704 SILVERSIDE DR GRAPEVINE TEXAS ASSISTANT BUILDING OFFICIAL: DONALD DIXSON JR NUMBER OF STORIES:ONE TOTAL SQ. FT: 4252 ZONING: R 7.5 OCCUPANCY: R-3 OCCUPANT LOAD: 10 EXITS REQUIRED: ONE FIRE SPRINKLED: BUILDING TYPE: V-B CU: N/A SP: N/A SPECIFIC COMMENTS: 1. NOT ALL COMMENTS ADDRESSED FROM PRIOR PLAN REVIEW. 2. SHOW AND LABEL CONTOURS 564 AND 572 ON THE SITE PLAN. A. PUBLIC WORKS DEPARTMENT APPROVAL IS REQUIRED FOR CONSTRUCTION WITHIN FLOOD PLAIN, CONTACT PAUL LEE OR JOHN ROBERTSON AT 817-410-3136. B. CONSULT CORPS OF ENGINEERS FOR APPROVAL REQUIREMENT FOR CONSTRUCTION WITHIN FLOWAGE EASEMENT, REVISE DRAWINGS AND RE- SUBMIT 3. PROVIDE ROOF RAFTER SIZE, SPACING, SPAN AND SPECIES, HEADER SIZES, POST LAYOUT. A. THE LVL SHOWN ON THE FLOOR PLAN DOES NOT ALIGN WITH THE LVL SHOWN ON THE FRAMING PLAN IN THE FAMILY AREA. REVISE DRAWINGS AND RE-SUBMIT 4. FOUNDATION PLAN DOES NOT MATCH THE FLOOR PLAN. THERE IS AN ADDITIONAL 6'- 6" BEYOND THE FIREPLACE. REVISE DRAWINGS AND RE- SUBMIT 5. PROVIDE A BEAM DETAIL FOR THE CONNECTION OF THE BEAM TO THE WALL AND ROOF OF EXISTING LOAD BEARING WALL. REVISE DRAWINGS AND RE- SUBMIT 6. CEILING JOISTS NEED TO SPECIFY SPECIES: SYP,DFL,HF AND DOES NOT INCLUDE #3 GRADE LUMBER. REVISE DRAWINGS AND RE-SUBMIT 7. THE 2 X 12 CEILING JOISTS ARE NOT IN THE SPAN TABLES OF THE 2006 IRC. REVISE DRAWINGS AND RE-SUBMIT 8. ROOF RAFTERS ARE NOT SIZED, DIMENSIONED OR CLASSIFIED. REVISE DRAWINGS AND RE-SUBMIT City of Grapevine Building Inspection Department Plan Review Comments P.O. Box 95104 Phone: (817) 410-3129 Grapevine, Texas 76051 Fax: (817) 410-3536 NAME OF PROJECT: HOLT RENTAL PROPERTY ADDRESS: 1704 SILVERSIDE DR GRAPEVINE TEXAS ASSISTANT BUILDING OFFICIAL: DONALD DIXSON JR NUMBER OF STORIES:ONE TOTAL SQ. FT: 4252 ZONING: R 7.5 OCCUPANCY: R-3 OCCUPANT LOAD: 10 EXITS REQUIRED: ONE FIRE SPRINKLED: BUILDING TYPE: V-B CU: N/A SP: N/A SPECIFIC COMMENTS: 1. NOT ALL COMMENTS ADDRESSED FROM PRIOR PLAN REVIEW. 2. SHOW AND LABEL CONTOURS 564 AND 572 ON THE SITE PLAN. A. PUBLIC WORKS DEPARTMENT APPROVAL IS REQUIRED FOR CONSTRUCTION WITHIN FLOOD PLAIN, CONTACT PAUL LEE OR JOHN ROBERTSON AT 817-410-3136. B. CONSULT CORPS OF ENGINEERS FOR APPROVAL REQUIREMENT FOR CONSTRUCTION WITHIN FLOWAGE EASEMENT. REVISE DRAWINGS AND RE- SUBMIT 3. PROVIDE ROOF RAFTER SIZE, SPACING, SPAN AND SPECIES, HEADER SIZES, POST LAYOUT. A. THE LVL SHOWN ON THE FLOOR PLAN DOES NOT ALIGN WITH THE LVL SHOWN ON THE FRAMING PLAN IN THE FAMILY AREA. REVISE DRAWINGS AND RE-SUBMIT 4. FOUNDATION PLAN DOES NOT MATCH THE FLOOR PLAN. THERE IS AN ADDITIONAL 6'- 6" BEYOND THE FIREPLACE. REVISE DRAWINGS AND RE- SUBMIT 5. PROVIDE A BEAM DETAIL FOR THE CONNECTION OF THE BEAM TO THE WALL AND ROOF OF EXISTING LOAD BEARING WALL. REVISE DRAWINGS AND RE- SUBMIT 6. CEILING JOISTS NEED TO SPECIFY SPECIES: SYP,DFL,HF AND DOES NOT INCLUDE #3 GRADE LUMBER. REVISE DRAWINGS AND RE-SUBMIT 7. THE 2 X 12 CEILING JOISTS ARE NOT IN THE SPAN TABLES OF THE 2006 IRC. REVISE DRAWINGS AND RE-SUBMIT 8. ROOF RAFTERS ARE NOT SIZED, DIMENSIONED OR CLASSIFIED. REVISE DRAWINGS AND RE-SUBMIT 9. SHOW ELECTRIC SERVICE ON ELEC FLOOR PLAN. IF SERVICE IS BEING RELOCATED, SHOW ON THE PLANS, REVISE DRAWINGS AND RE-SUBMIT 10. PROVIDE NOTE THAT BEARING IS TO MEET 2006 IRC SEC R502.6 FOR ALL JOISTS, REWFTERS AND BEAMS. REVISE DRAWINGS AND RE-SUBMIT 11. PROVIDE LOT DRAINAGE PLAN TO PUBLIC WORKS FOR REVIEW AND APPROVAL. REVISE DRAWINGS AND RE-SUBMIT GENERAL NOTES: 1. ALL EGRESS DOORS ARE TO BE OPENABLE FROM DIRECTION OF EGRESS WITHOUT THE USE OF KEY, SPECIAL EFFORT OR KNOWLEDGE. PROVIDE HARDWARE INFORMATION ON COMMENTS FOR DOOR SCHEDULE. 2. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. 3. THE PROJECT SHALL BE DESIGNED TO COMPLY WITH THE 2015 IECC. VERIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE CITY BY AN ICC CERTIFIED ENERGY CODE INSPECTOR PRIOR TO THE ISSUANCE OF BUILDING FINAL APPROVAL OR CERTIFICATE OF OCCUPANCY. 4. THE CITY OF GRAPEVINE IS UNDER THE 2006 1 CODES WITH THE 2015 I.E.C.0 AND THE 2005 N.E.C. PLEASE PROVIDE FOR THESE CODES ON THE PROJECT DATA INFORMATION TABLE AND THE PROJECT DESIGNS. 5. ALL CHANGES FROM THE CITY APPROVED PLANS WILL REQUIRE REVISED PLANS SUBMITTED AND ADDITIONAL REVIEW FEES DUE. 6. ALL MECHANICAL EQUIPMENT IS REQUIRED TO BE SCREENED FROM PUBLIC VIEW. SCREENING TO INCLUDE ALL MECHANICAL EQUIPMENT ON SITE. 7, PLEASE READ THE FOLLOWING NOTE CAREFULLY AND FOLLOW THE INSTRUCTIONS PROVIDED. PLANS WILL NOT BE ACCEPTED THAT ARE REVISED AND UO INO l FOLLO`v"d THESE REQUMICIVIEi ITS. THANK YOU. Please review comments and have designers add all review comments, required information and created changes, all clouded within new plan sets. Please provide 3 copies of new full corrected plan sets. Plan size may not exceed 36" in any dimension. A copy of this plan review letter shall accompany the "response to comments" sets of drawings. Provide one set to city that is bolted if plans are over 10 pages. Thank you for your time and consideration. APPLICATION RECEIVED: 1ST COMMENTS: REVISIONS RECEIVED: REVISIONS REVIEWED: PERMIT ISSUED: Manda Pancholy From: Manda Pancholy Sent: Tuesday, April 11, 2017 5:37 PM To: ' Subject: FW: 17-1166 1704 Silverside Dr(Addition) From: Manda Pancholy Sent:Tuesday,April 11, 2017 5:36 PM To: ' Subject: 17-1166 1704 Silverside Dr(Addition) Bailey Draper, In reference to above permit please provide required in formation in response to following comments. Comments: Show and label 564 and 572 counter line on the site plan. Public Works Department approval is required for construction within flood plain, contact Paul Lee or John Robertson at 817-410-3136. Consult Corps of Engineers for approval requirement for construction within flowage easement. Roof shall not extend over drainage easement. Driveway material shall be as per Zoning Ordinance section 58.Gravel driveway is not permitted. Provide building coverage and impervious area coverage information. Label minimum finish floor elevation on the floor plan. Foundation dimension and location of outdoor fireplace shall match with floor plan. Provide stud wall size, spacing, ceiling joist, roof rafter, beam, header, post layout detail with framing member size, spacing, span,type of wood. Provide beam detail for roof support at demolition of existing load bearing wall. Fence and retaining wall require separate permits. Fence and any construction on/within front right of way shall be removed. Clarify the swimming pool is existing? Provide lot drainage plan in one copy for Public Works Department approval. Manda Pancholy Plans Examiner City of Grapevine 817-410-3160 t Manda Pancholy From: Don Dixson Sent: Wednesday, June 14, 2017 12:37 PM To: Cc: Manda Pancholy Subject: 1704 Silverside Dr. Attachments: 1704 SILVERSIDE DR.doc Please see attached plan review letter and call if you have any questions. Manda @ 817-410-3160 or myself at the number in the signature line. Regards. Don Dixson, CBO Assistant Building Official Grapevine Development Services 200 S Main St Grapevine Texas 75099 817-410-3129 817-454-1966 1 Manda Pancholy From: Myers, Kenneth D CIV USARMY CESWF (US)< Sent: Wednesday, June 28, 2017 12:26 PM To: Manda Pancholy Cc: Mathney, John L CIV USARMY CESWF (US) Subject: RE: 17-1166 1704 Silverside Dr(Addition/Remodel) Thanks for sending this over Manda. We have researched this property and it falls under one of the rare situations where the Corps of Engineers did not purchase the flowage easement on the property. Based on our research, our authority would stop at the property line in this situation. They'll likely still have to deal with FEMA, but they won't need our approval. Thanks, Kenneth Myers Grapevine Lake Manager 817-865-2604 -----Original Message----- From: Manda Pancholy [ Sent:Wednesday,June 28, 2017 11:23 AM To: Myers, Kenneth D CIV USARMY CESWF (US) <Kenneth.Myers @usace.army.mil> Subject: [Non-DoD Source] 17-1166 1704 Silverside Dr(Addition/Remodel) Kenneth Myers, Good morning. I called you today but you were out in the field. I have above permit for remodel and addition to existing house. I want to know if your review and approval is required for this permit.There is 564 and 572 contour lines labeled on the plat. I will appreciate your help in this matter. Manda Pancholy Plans Examiner City of Grapevine 817-410-3160 *** External email communication—Please use caution before clicking links and/or opening attachments *** 1 Manda Pancholy From: Manda Pancholy Sent: Friday, June 30, 2017 11:47 AM To: ' Subject: 17-1166 1704 Silverside Dr (Addition/ Remodel) Bailey Draper, In reference to above permit please provide required information in response to following comments. Provide response to drawings in two hard copies. Comment: Provide survey of the property showing flood plain line (564 elevation) and drainage easement on ( it as per engineering department). Construction within flood plain and/or fill for new addition require Public Works Department approval, contact Paul Lee or John Robertson for the fill permit or construction within flood plain. Label minimum finish floor elevation on the site plan/floor plan Minimum 572.5'. Provide engineered drawings for cedar wood construction in new arbor and deck. Provide foundation detail for the posts. If new deck is concrete deck attached to existing house slab provide engineered detail for the footing and slab. Provide detail for structural support at demolition of load bearing structures. Provide rafter framing plan for all new roof to be constructed with size, span, spacing, species of rafter. Show existing and new smoke detectors on the electrical drawing, must comply with Section R 313 of IRC 2006. (you can label these on the submitted electrical drawing). Awaiting for lot drainage approval. Manda Pancholy Plans Examiner City of Grapevine 817-410-3160 t S U R V E Y P L A T . TO THE LIENHOLDERS AND/OR OWNERS AND PURCHASERS OF THE PREMISES SURVEYED ANIr FIRST AMERICAN TITLE INSURANCE COMPANY: This is to certify that I have, this date, made an on the ground survey of the property I located on Silverside Drive in the City of Grapevine, Texas, described as follows: Lot 75R, Shorecrest Acres, an Addition to the City of Grapevine, Tarrant County, Texas, according to the plat thereof recorded in Cabinet A, Slide 11289, of the Plat Records of Tarrant County, Texas. I \ U) 5/8'IRF I _ 25'BUIIDI r GAL 389-4 L.PC.G.al pPPROxIMATE LOCATION ERA A OF ZONE BE PER 9 I PANE NUMBER 4813800205 M UNITED STATES OF AMERI A 0 DATED 08/02/1995 u I CORPS OF ENGINEERS O! I (TRACT NO. A-22A) o N 00 LOT 74 \ CAUSE NO. 2115 / f SHORECREST ACRES a'unutt ESMT. fw'I o i VOL. 388—L, PG. 81 see-1,Pc. el 0 I CHAINUNK I /2 FENGE � o N89'22'03"E 190.32' 1/2 IRF 4'unutt 6112. 11289 ASPHALT I 98 J .2' m.1. ORAVEL , \ AP / D=2231'57" D«D , CK 5,4C \ o R=185.00 q a° / L=88.90' ( I GRA E e "E IS HOU CB=N14'20'59" I I Po 9m .7 CD=88.05' X I ® \ Sid PENCE WOOD cRAVa POWER 1 IR 2' POI£ CR GAS ' MY � m 11EDTMITY T. ♦� WIRE CAB. A.SU 1 8 LOT 75R SHORECREST ACRES DRAINAGE ESMT. s 0 A. SLIDE 11289 CAB' A.SU E 1128 I /z As G, N MONUMENT G Os 1//z IRF ASPHALT L 1/2' IRF 92.07 1/2'IRS 1/2'IRFL1 SR173 J W \ \ 1'IPF LIP 2 C �, y\ 1/2'IRF 11Y IRS 4'URUW ESMT. \ , LOT 1A LOT 76 vat 388-L. PG. 91 YT SHORECREST ACRES /•(\ 1/2'IRF SHORECREST ACRES 1� VOL. 388—L, PG. 81 V� \ CAB. A, SLIDE 11289 NOTES: 30'BUIWING UNE 1. IRF - Iron Rod Found �\ CAB.A. suOe 112M OF TF \ 2. Basis of Bearing - Subject Plat LINE TABLE *: ... .....................:.... LINE LENGTH BEARING 1/2'IRF Hugh E. Peiser L1 34.88 S84'3111 05" ............. ................. L2 1 24.84 1 S65.47'55"W �':?� 3688 2- CURVE TABLE ILINEI DELTA I RADIUS I LENGTH CHORD BEARING CHORD LENGTH Ci 24.57'02" 20.00' 1 8.71' 1 578.03'17"W 8.64' Tnb N,my P"rwm•a"wnnaelkn M a•bmwctbn aa•vBSi a W.Na to-00WO8.0 o1 FYR Amslm,TM.Mesa.awnpmy. .of THIS SUR1£Y FOR MY OTHER fl1RPp$E OR BY OVER PMTR WALL BE AT THEIR OWN RISK AND UN ERSIGNED IS NOT RESPONSIBLE TO OTHERS FOR MY UYSS g6uLnNC THaatIR M. FL000 CISIMCAM M GLw. by a•PLOCO INSURANCE RATE MAPS W T.t Cwnty,T...a pM er M.-bpct p-Mt,Doe•IN„IoM a SpxJd nW Hwwe Nen(100 Yv FlooaJ,Yap eeb 08/02/1896 C--fty P.0 Nw 101 135 H•ubj a lot b Mmt•a M Z..'AE'S'%'. If aY eNe b nN.IoM m M UW noon h.vq Mb 19 M SYNmea aom not"y am a.property ma/w"buch„a ahem M M Rw nwn fl A,w neM ama9.pi rv. •atteknR Tatw naab rn ma MI Dear ma II•otl MgbY may M 1w.mep py mm-moae w no4uy amwe.iM1b Floea Slabmmt N,N net wqb Ilminy m a.pt M Ux 9mgpr, m�Mat nwm M o wa cwr«t ma awvrw.,.prmiwtW ar as p,ep.ty w e.tw,nM.e by m w,a.9.mna PRELIMINARY N e,bleot to mr me aI eugnenb,I.mrwlbn.me,Wkd t oat mar bs el,dewy a.Ihn ma eMmtlon. M wM propw<r b•M9 Maka[•a by ae qaL a.a Io W ma tp•m —tyw ma knpro"mNlb we w Nam.aI snpmmmNa b.M9 NIaM a.bwmewb.ar a•prtpNty est boa bwn pwmmlr Onw as wtmw Makatea.ma a. Welmw bwn a.newest MtN..ptkn w MWwtM b w Nom m mM plat aN.w.no.ba.mwweNnmeA HUGH E. PEISER eennlem w IlmBpelwu Nmpt u Nam. Rq.t..e PmN.ima Lma verger Nn xm JOB NO. PEISER SURVEYING 00. P-36435 w-w-w.peisersurveying.com DATE: 01/11/2007 r.Ka. p S SCALE: 801 ENTERPRISE DRIVE sPr$OCaYan 1' = 40' FLOWER MOUND, TEXAS 75028 Co 972` 724-5776 COMMERCIAL • RESIDENTIAL DRAWN BY: 972E 724-5779 FAX BOUNDARIES TOPOGRAPHY C.A. I MORTGAGE 3 �vL $z� €3E 8 R o 'yTa e s� N E fos°r $§Q8R Q n R E �W '37� a E°Y �B� '. r R 7 mEj oeE cu .7i mg F,g wa E BRo �RF r{I U� a$o1i` O °§S� I�tS' I y^.c .` ° c '� z°� +_ O E° Ez s E $ 8ta w y o z �� I I It A S: i Y r I s ., rb I"i °i C k ° ' E r I' `5 F { F E �$ U E 4E E 'eIm i6 Ee F e . o,Y ZS v FT7 °S KATIEIS WOODS DR N 3 = to •� - 'S\� �"J'/ Q�F NQ nT` I� qq G ytiI l Wn.�r �i�2 3 I`J y�=i nV'�^�. SPY LeF � •(�l/.�i 11 I t. o O Un.C-Wn J�ZUp A N �4N, UU I N ct ro oe g yeS j � D .JJW�O y Op, vi � z Z K Yi I € ti�'ml ur 4 11'0��� R�`�' i -�. 51 OfG?� y� � ! I z to "A cz; lilwz Q vi M � �n090�W W G� A& �� � ���¢� .Ta 41 % Y` �If•.la�h9°mN W V &5.28'5,26' DE D RIVE � D R-0.W.1 �I— ! G l.OId�II�AM _ ? m: yy -° _ rn ��" �^� A _ 'W`j Y = R n I Ln F. z33�3 W 4 W F F- Olq rYW -`cti2e ` o N41 pI O O 41M p J Ln 4� A z E _'N 1•I WI ImW is — —Z1d-SH319NV— — 8 iU WI 8 N r r � t=Z4V J416lOL '� 1 V IvvYY, Inu�u vn� ,vvvn �� rvrur , „u-.+ ��+� . •+, ELEV.=574.00 N89 '03°E 190.32' 112" IRF , ZONED: R-7.5 .1 JIM W. JONES, DARYLE W. YVAN SA JACKSON d 1/z I 15• BUILDING u ZONED: R-7.5 F SHORECREST ACRES, an ddition to e City f Grapevine, m+TRauv}1 VOL 3N-4 PD. e1 lie use forever that right- -way and asemen hown LOT 56 LOT 57 zo MDNUM T TO BE ABANDON LOT 75R O.B. p BY THIS PLA . res ved for the purposes as i 'caked. The tility easemen s 0o O SHORECREST ACRES for ch particular use. The ma i nonce of wing on the & W i LOT 75 25,808 SQ. FT. No bu ings or auxiliary structures hall be co tructed, recc (,4 s�loR CREST CRES OR 0.59 ACRES easeme as shown. Said easemen being her reserved 1 117; O n vrlL. 8— G. 81 o utilities u ' g, or desiring to use sam Any City franchise MIN. FINISHED FLOOR = 572.5' m aF-war U T. ! removed of r parts of any fences, tre shrubs, other c RIGHT CATION � ev _-- ^_____ ,- spective s em on the easements and II City or nchise DEC BY I Ii$ PLAT I DRRAINnGEE EM i ress and eg ss to and from and upon id easeme I S fo 1/2" IRF 1/2" IRS o- OLD LOT S89'53.00'E 193.00 BY THIS PLAT ins acting, patr g, maintaining, and addin to or r oving 1/2" ' J uSTREEf ABANDONMEN nee e ity at anyti of procuring the permiSS anyone. L „ IRS L , & DRAINAGE ESMT, N89053 W BY THIS PLAT _,,_,_„_,_ _,,, � ,r This rep t approved bject to all platting ordinances, rules, 92 T Texas. (BASE BEARING} 1/2” IRF V89'53°00"W 330.00' MONUMENT T/2 IRS L5< N,.IRS . LD T. Hess my nd this — — day of =��r IRF N89'53'00"W 110.00' 1/2" IRF N89'53'00"W 110.00' N89'53.00"W A� \..6 1/7' IRF 'Ne9''oo•w,ze.ao• - ------ 46.00 J t/2" I S t IRF ones ^N /2" . STATETLW Y OF , LOT 3 LOT 2 LOT 1 6+, RANT SHORECRE T ACRES OT 76 Before me, undersigned Notary Public in and for said county 1� ' HORS EST AC S Jones, known to be the person whose name is subscribed to VOL. 388 L, PG. 81 ` that he executed the some for thh7 purposes and considerati 49,77 SQ. FT. of office this —L_ day of J�u —�_� 2006, OR 1.1 ACRES \ APPROXIMATE LOCATION OF ZONE "X' PER FEMA (C _----- --- _A N OOR = 572.5 PANEL NUMBER 4843900205 H Not y Public, State of Te s t6 31, LOT A \ j DATED 08/02/1995 My Commission Expires-�!5 OL. 38 -L AC 6: OViS 1WHI WT O OL. 388-L 81 \ Wit ss �1 a/ 1/' nd his ____ day of � rtrt X// (�ESCft REAI USE OF V[�/J� ` 0 _ --____ ----- ' p 30' BUILDING BY THIS PLATE (n Daryl W. Ussery aim UNOW FE LAWV ✓ t3+ STATE OF TEXAS ZON R— 5 S S COUNTY OF TARRANT AKE OD ACR 1/2" IRS r d 388- 39, P,_6asr T , T} ` Before me, undersigned Notary Public in and for said county T TX } F&ED Ussery, known ed be the person whose name a subscribed t TIE 1 \ that he executed the same for the purposes and considerati ik11e Bad V � of office f day of 2006. G�s�iOED M aril texas paged 9Vee11ed R1xua�fJ \ i - / ;•1::,s t nty. as • by Notary Public, State of Te�xgs ` / My Commission Expires__5lls.�=� sC TAC T�T�7 Witness my hand this day of —s:_ZZ4P ._____ GPS COORDINATE ��//J�� '^ 'Z 2 'J `0 ��>� N=7033771.49 Sustl k E=2407618.82 y z�. ELEV.=574.00' ` STATE OF TEXAS // ! COUNTY OF TARRANT 50 t APPRO ATE LOCATION OT FREEMAN SURVEY, ABSTRACT NO. 526 \ Before me, undersigned Notary Public in and for said county APPRO ATE LOCATION OF A F. LEONARD SURVEY, ABSTRACT N0. 946 1/z, I Jackson, known to be the person whose name is subscribed es, such those the ernment holds oyes 1/r IRF ` that he executed the same for the purposes and considerat A 1/2' IRF BEARS roa•5o`E 2.30' � of office this _L__ day of _.t.�=�_—__, 2006. Grap ine Lak ant to the government nnwA. n.ixdicna and Anngmgrrhs 4n nrencinnnIIv