HomeMy WebLinkAboutTerracon - 10/4/2018 (4)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0482 Service Date: 10/04/18 2501 E Loop 820 N Report Date: 10/11/18 Revision 1 - 7 -day results Fort Worth, TX 76118-6978 Task: 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9727 Supplier: Argos Batch Time: 1311 Plant: 123 Truck No.: 1736 Ticket No.: 12333175 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 61/2 5-7 4.3 3-6 95 90 144.8 Laboratory Test Data Set Specimen Avg Diam. Area Date Date No. ID (in) (sq in) Received Tested Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information A Sample Date: 10/04/18 Sample Time: 1406 Sampled By: Christopher Thompson Weather Conditions: Clear Accumulative Yards: 9/36 Batch Size (cy): 9 Placement Method: Bucket & lift Water Added Before (gal): 7 62,200 4,950 4 Water Added After (gal): C Sample Location: Garage Elevator Wall Upturn Beam, 10/05/18 Grid Line P9/15 Placement Location: Garage Elevator Wall Upturn Beam D 4th and 5th Floor, Grid Line 12.57 P9 -P11/15; Columns, Grid Line, 11/01/18 P8/15, P12/15, P10/18, P11/18, 1 P12/17.8 Age at Maximum Compressive Test Load Strength Fracture Tested (days) (lbs) (psi) Type By 1 A 4.00 12.57 10/05/18 10/08/18 4 57,220 4,550 4 1 B 4.00 12.57 10/05/18 10/11/18 7 62,200 4,950 4 1 C 4.00 12.57 10/05/18 11/01/18 28 1 D 4.00 12.57 10/05/18 11/01/18 28 1 E 4.00 12.57 10/05/18 11/01/18 28 1 F 10/05/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Terracon Rep.: Christopher Thompson Reported To: Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Paae Report Number: 95181011.0482 Service Date: 10/04/18 Report Date: 10/11/18 Revision 1 - 7 -day results Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Jaehyung Ahn (1) Manhattan Construction Co, Klint Robertson (1) Manhattan Construction Co, Matthew Powell (1) Manhattan Construction Co, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600