HomeMy WebLinkAboutTerracon - 11/12/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0540
Service Date: 11/10/18 2501 E Loop 820 N
Report Date: 11/12/18 Fort Worth, TX 76118-6978
Task: Hotel 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 7,000 psi @ 28 days
Mix ID: 9908
Supplier: Argos
Batch Time: 0829 Plant: 110
Truck No.: 6270 Ticket No.: 11033280
Field Test Data
Test
Result
Specification
Slump (in):
10 1/2 *
6-9
Air Content (%):
1.2
0-3
Concrete Temp. (F):
62
50-95
Ambient Temp. (F):
38
Sample Location:
Plastic Unit Wt. (pcf):
149.7
E/6 Elevator All pit walls, 1 st to 2nd
Yield (Cu. Yds.):
* = Field Test Results do not meet project specifications.
Laboratory Test Data
Set Specimen Avg Diam.
No. ID
(in)
1 A
4.00
1 B
4.00
1 C
4.00
1 D
4.00
1 E
0
Initial Cure: Outside
0
Sample Date:
11/10/18 Sample Time: 0930
Sampled By:
Adam Wood
Weather Conditions:
Partly Cloudy
Accumulative Yards:
9 Batch Size (cy): 9
Placement Method:
Bucket & lift
Water Added Before (gal):
0
Water Added After (gal):
0
Sample Location:
Column E.8/12
Placement Location:
E/6 Elevator All pit walls, 1 st to 2nd
level Columns E.8/12, E.2/12, G.6/12,
Hold
G.6/13
Age at Maximum
Area
Date Date
Test Load
(sq in)
Received Tested
(days) (lbs)
12.57
11/17/18
7
12.57
12/08/18
28
12.57
12/08/18
28
12.57
12/08/18
28
Hold
Final Cure: Moist Room
Comments: David Saiter with Manhattan was notified of the excessive slump.
Samples Made By: Terracon
Compressive
Strength Fracture Tested
(psi) Type By
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Adam Wood
Reported To: David w/ Manhattan
Contractor: Manhattan
Report Distribution:
See attached distribution list. Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Paae
Report Number:
95181011.0540
Service Date:
11/10/18
Report Date:
11/12/18
Task:
Hotel
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) City of Grapevine TX, Hans Strayer
(1) City of Grapevine TX, Paul M Lee
(1) City of Grapevine TX, Scott Williams
(1) City of Grapevine TX, sbatte@grapevinetexas.gov
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Klint Robertson
(1) Manhattan Construction Co, Matthew Powell
(1) Manhattan Construction Co, Robert Montgomery
(1) Walker Consultants, Martha M. Villanueva
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
DEVIATION LOG Irerracon
Report Date: 11/14/2018
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number:
95181011
Deviation No. Report No.
Service
Service Date
Description/Comments
How Resolved
Date Resolved
Status
D000001
0047
Concrete Compressive
02/15/18
Slump does not comply, Set 1
Concrete met specified
02/22/18
Closed
Strength Test
strength
D000002
0212
Field Density Testing
04/26/18
Moisture content does not comply, Test
Retested
04/27/18
Closed
1
Comments: Low Moisture Content.
David with Manhattan was notified.
D000003
0212
Field Density Testing
04/26/18
Moisture content does not comply, Test
Retested
04/27/18
Closed
2
Comments: Low Moisture Content.
David with Manhattan was notified.
D000004
0212
Field Density Testing
04/26/18
Moisture content does not comply, Test
Retested
04/27/18
Closed
3
Comments: Low Moisture Content.
David with Manhattan was notified.
D000005
0212
Field Density Testing
04/26/18
Moisture content does not comply, Test
Retested
04/27/18
Closed
4
Comments: Low Moisture Content.
David with Manhattan was notified.
D000006
0212
Field Density Testing
04/26/18
Moisture content does not comply, Test
Retested
04/27/18
Closed
5
Comments: Low Moisture Content.
David with Manhattan was notified.
D000007
0169
Concrete Compressive
04/11/18
Average compressive strength does not
56 day compressive
06/06/18
Closed
Strength Test
comply, Set 1 Age 28
strength tested at 4550
psi
D000008
0232
Concrete Compressive
05/08/18
Slump does not comply, Set 1
Concrete met strength
06/05/18
Closed
Strength Test
D000009
0249
Field Density Testing
05/16/18
Moisture content does not comply, Test
Retested
05/16/18
Closed
65
Page 1 of 5
DEVIATION LOG
Report Date: 11/14/2018
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Deviation No. Report No. Service Service Date Description/Comments How Resolved Date Resolved Status
D000010
D000011
D000012
D000013
D000014
D000015
D000016
D000018
0271
0271
0271
Field Density Testing
Field Density Testing
Field Density Testing
0273 Field Density Testing
0273 Field Density Testing
0169 Concrete Compressive
Strength Test
0332 Post -Tension Stressing
0342 Concrete Compressive
Strength Test
05/30/18
Percent compaction does not comply,
Retested Same Day
Closed
Test 1
Closed
05/30/18
Percent compaction does not comply,
Retested Same Day
Test 2
05/30/18
Percent compaction does not comply,
Retested Same Day
Test 3
05/31/18
Percent compaction does not comply,
Retested Same Day
Test 69
05/31/18
Percent compaction does not comply,
Retested Same Day
Test 71
04/11/18
Average compressive strength does not
56 day compressive
comply, Set 1 Age 56
strength tested at 4550
psi
07/02/18
Post -Tension Stressing
Closed out by RFI
Comments: David Saiter w/Manhattan
#171
was notified and given a copy of the
field report.
07/07/18
Air content does not comply, Set 2
Closed by RFI #227
D000019 0342 Concrete Compressive 07/07/18 Air content does not comply, Set 3
Strength Test
Page 2 of 5
Coring Report
accepted by Structural
Engineer
Closed by RFI #227
Coring Report
accepted by Structural
Engineer
05/30/18
Closed
05/30/18
Closed
05/30/18
Closed
05/31/18 Closed
05/31/18 Closed
06/06/18
07/19/18
09/07/18
09/07/18
Closed
Closed
Closed
Closed
DEVIATION LOG
Report Date: 11/14/2018
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Deviation No. Report No. Service Service Date Description/Comments How Resolved Date Resolved Status
D000020
0342
Concrete Compressive
Closed
09/10/18
Strength Test
D000021
0342
Concrete Compressive
Strength Test
D000022
0344
Concrete Compressive
Strength Test
D000023
0359
Concrete Compressive
Strength Test
D000024
D000025
D000026
0359 Concrete Compressive
Strength Test
0362 Concrete Compressive
Strength Test
0342 Concrete Compressive
Strength Test
D000027 0342 Concrete Compressive
Strength Test
07/07/18
Air content does not comply, Set 4
Closed by RFI #227
Closed
09/10/18
Coring Report
09/07/18
Closed
accepted by Structural
Engineer
07/07/18
Slump does not comply, Set 1
Closed by RFI #227
Coring Report
accepted by Structural
Engineer
07/09/18
Slump does not comply, Set 1
Pending 28 day
Comments: 28 day compressive strength
compressive strength
obtained the required 4500 psi.
result
07/16/18
Slump does not comply, Set 1
Resolved at 28 day
Comments: 56 Day meets the required
compressive strength
5000 psi
results
07/16/18
Slump does not comply, Set 2
Resolved at 28 day
Comments: 56 Day meets the required
compressive strength
5000 psi
results
07/17/18
Slump does not comply, Set 1
28 day average
Comments: Manhattan was notified of
compressive strength
excessive slump prior to placement.
was 5,610psi.
07/07/18
Average compressive strength does not
Closed with RFI #227.
comply, Set 2 Age 28
Accepted by Structural
Comments: Low 28 day compressive
Engineer base on core
strength results
strengths.
07/07/18
Average compressive strength does not
Closed with RFI #227.
comply, Set 3 Age 28
Accepted by Structural
Comments: Low 28 day compressive
Engineer base on core
strength results
strengths.
Page 3 of 5
09/07/18 Closed
09/07/18
Closed
08/06/18
Closed
09/10/18
Closed
09/10/18
Closed
08/04/18
Closed
09/07/18
Closed
09/07/18 Closcd
DEVIATION LOG
Report Date: 11/14/2018
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Deviation No. Report No. Service Service Date Description/Comments How Resolved Date Resolved Status
D000028
D000029
D000030
0387 Field Density Testing 07/30/18 Moisture content does not comply, Test Retested
109
Comments: David Saiter was notified by
Terracon that moisture was low. Will
retest after area is reworked.
0387 Field Density Testing 07/30/18 Moisture content does not comply, Test Retested
0396
D000031 0359
D000032 0359
D000033 0406
D000034 0342
Page 4 of 5
08/01/18 Closed
08/01/18 Closed
09/03/18 Closed
09/10/18
09/10/18
Closed
Closed
110
Closed
09/12/18
Closed
Comments: David Saiter was notified by
Terracon that moisture was low. Will
retest after area is reworked.
Concrete Compressive
08/06/18
Slump does not comply, Set 1
28 day compressive
Strength Test
Comments: Contractor was notified of
strengths meet the
excessive slump pior to placement.
specified strength at 28
days
Concrete Compressive
07/16/18
Average compressive strength does not
Meets the specified
Strength Test
comply, Set 1 Age 28
strength at 56 days
Comments: 56 Day meets the required
5000 psi
Concrete Compressive
07/16/18
Average compressive strength does not
Meets the specified
Strength Test
comply, Set 2 Age 28
strength at 56 days
Comments: 56 Day meets the required
5000 psi
Concrete Compressive
08/15/18
Air content does not comply, Set 2
Meets the specified
Strength Test
strength at 28 days
Concrete Compressive
07/07/18
Average compressive strength does not
Meets the specified
Strength Test
comply, Set 2 Age 56
strength at 28 days
Page 4 of 5
08/01/18 Closed
08/01/18 Closed
09/03/18 Closed
09/10/18
09/10/18
Closed
Closed
09/12/18
Closed
09/12/18
Closed
DEVIATION LOG
Report Date: 11/14/2018
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Deviation No. Report No. Service Service Date Description/Comments How Resolved Date Resolved Status
D000035
D000036
D000037
D000038
D000039
0342 Concrete Compressive
Strength Test
0399 Concrete Compressive
Strength Test
0480
0492
0540
Concrete Compressive
Strength Test
Mortar Compressive
Strength Test
Concrete Compressive
Strength Test
07/07/18
Average compressive strength does not
Closed out by RFI
comply, Set 3 Age 56
#227. Accepted by the
Structural Engineer
based on the Core
report.
08/09/18
Average compressive strength does not
Walker Consultants
comply, Set 3 Age 28. Average PSI at
RFI #230
28 days is 4,700psi.
Comments: 28 day did not meet the
required strength of 5,000 psi. Will
review again at 56 days.
10/03/18
Air content does not comply, Set 1
Comments: Notified Manhattan of test
result on site. Review at 28 days
10/12/18
Average compressive strength does not
comply, Set 1 Age 28
11/10/18
Slump does not comply, Set 1
Comments: Needs Structural Engineer
approval at 28 day compressive
strengths.
Page 5 of 5
09/07/18
11/05/18
Closed
Closed
Open
Open
Open