HomeMy WebLinkAboutTerracon - 11/13/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0521
Service Date: 11/05/18 2501 E Loop 820 N
Report Date: 11/13/18 Fort Worth, TX 76118-6978
Task: Parkine Garace 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 5,000 psi @ 28 days
Mix ID:
9727
Supplier:
Argos
Batch Time:
1544
Truck No.:
6238
Field Test Data
Test
Slump (in):
Air Content (%):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Yield (Cu. Yds.):
Laboratory Test Data
Plant: 123
Ticket No.: 12333815
Result Specification
7 5-7
5.9 3-6
80
79
143.0
Set
Specimen
Avg Diam.
Area
No.
ID
(in)
(sq in)
1
A
4.00
12.57
1
B
4.00
12.57
1
C
4.00
12.57
1
D
4.00
12.57
1
E
Initial
Cure: Outside
Comments:
Date
Date
Received
Tested
11/06/18
11/12/18
11/06/18
12/03/18
11/06/18
12/03/18
11/06/18
12/03/18
11/06/18
Final Cure:
Sample Date:
11/05/18 Sample Time: 1620
Sampled By:
Taylor Henson
Weather Conditions:
Clear
Accumulative Yards:
9/9 Batch Size (cy): 9
Placement Method:
Bucket & lift
Water Added Before (gal):
0
Water Added After (gal):
0
Sample Location:
Garage Bumper Wall, Level 5, Grid
Line P4 -P5/15
Placement Location:
Garage, Level 5, Columns, Grid Line
P1/15, P1/15.7, P1/16, P1/16.4,
P1/16.7, P1/17.3 and Bumper Walls,
Grid Line P4 -P5/15
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 77,070 6,130
28
28
28
Hold
Moist Room
Fracture Tested
Type By
4
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Taylor Henson
Reported To: David w/ Manhattan
Contractor:
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page Irerracon
Report Number: 95181011.0521
Service Date: 11/05/18 2501 E Loop 820 N
Report Date: 11/13/18 Fort Worth, TX 76118-6978
Task: Parking Garage 817-268-8600
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) City of Grapevine TX, Hans Strayer
(1) City of Grapevine TX, Paul M Lee
(1) City of Grapevine TX, Scott Williams
(1) City of Grapevine TX, sbatte@grapevinetexas.gov
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Klint Robertson
(1) Manhattan Construction Co, Matthew Powell
(1) Manhattan Construction Co, Robert Montgomery
(1) Walker Consultants, Martha M. Villanueva