HomeMy WebLinkAboutTerracon - 11/13/2018 (4)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0537
Service Date: 11/09/18 2501 E Loop 820 N
Report Date: 11/13/18 Fort Worth, TX 76118-6978
Task: Parking Garage 817-268-8600 Reg No: F-3272
Client
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Specimen
Project
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Area
Material Information
Date
Sample Information
Strength Fracture Tested
Specified Strength: 5,000
psi @ 28 days
Sample Date:
11/09/18 Sample Time: 0937
Received
Tested
Sampled By:
Christopher Thompson
Mix ID: 9041
A
Weather Conditions:
Clear
Supplier: Argos
11/12/18
Accumulative Yards:
9/45 Batch Size (cy): 9
Batch Time: 0900
Plant: 110
Placement Method:
Pump
Truck No.: 6222
Ticket No.: 11033239
Water Added Before (gal):
Field Test Data
C
Water Added After (gal):
12.57
11/10/18
12/07/18
Sample Location:
Grid Line P5.5/16
Test
Result Specification
Placement Location:
Elevated Deck, Level 6, Pour 1B,
Slump (in):
9 5-9
28
Grid Line P5.5 -P7.5/16-17
Air Content (%):
6.0 3-6
4.00
12.57
Concrete Temp. (F):
62
28
Ambient Temp. (F):
46
Plastic Unit Wt. (pcf):
138.8
Hold
Yield (Cu. Yds.):
Cure: Outside
Laboratory Test Data Age at Maximum Compressive
Set
Specimen
Avg Diam.
Area
Date
Date
Test Load
Strength Fracture Tested
No.
ID
(in)
(sq in)
Received
Tested
(days) (lbs)
(psi) Type By
1
A
4.00
12.57
11/10/18
11/12/18
3 44,810
3,570 4
1
B
4.00
12.57
11/10/18
11/16/18
7
1
C
4.00
12.57
11/10/18
12/07/18
28
1
D
4.00
12.57
11/10/18
12/07/18
28
1
E
4.00
12.57
11/10/18
12/07/18
28
1
F
11/10/18
Hold
Initial
Cure: Outside
Final Cure:
Moist Room
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Christopher Thompson
Reported To:
Contractor:
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page Irerracon
Report Number: 95181011.0537
Service Date: 11/09/18 2501 E Loop 820 N
Report Date: 11/13/18 Fort Worth, TX 76118-6978
Task: Parking Garage 817-268-8600
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) City of Grapevine TX, Hans Strayer
(1) City of Grapevine TX, Paul M Lee
(1) City of Grapevine TX, Scott Williams
(1) City of Grapevine TX, sbatte@grapevinetexas.gov
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Klint Robertson
(1) Manhattan Construction Co, Matthew Powell
(1) Manhattan Construction Co, Robert Montgomery
(1) Walker Consultants, Martha M. Villanueva