RE: HISTORIC PRESERVATION COMMISSION
CERTIFICATE OF APPROPRIATENESS #CA18-127
1953 D. E. BOX HOUSE
DAT AND BECKY NGUYEN, OWNERS
924 EAST WORTH STREET
GRAPEVINE, TEXAS 76051
This letter confirms on November 12, 2018 the Historic Preservation Staff approved with
conditions #CA18-127 for the property addressed 924 East Worth Street, legally described
as Block: 9, Lot: 3R, D. E. Box Addition, Grapevine, City of, GV to the Grapevine Historic
Preservation Ordinance 91-73 (Appendix G — Grapevine Code of Ordinances), as amended,
for the following:
1. Install concrete pilings, adjust existing pilings and reset/reshim understructure to
stabilize foundation of house;
as indicated on the attached plan with the condition a permit is obtained from the Building
Department.
An approved Certificate of Appropriateness is not an approved building permit; a
building permit °is / is not required. Contact the City of Grapevine's Building
Department at 817.410.3165 for fees and information regarding permits.
Thank you,
Z ov,, �,
David Klempin
Historic Preservation Officer
wdk
cc. Property Owner
CA File
THE CITY OF GRAPEVINE
HISTORIC PRESERVATION • 636 South Main Street • Grapevine, Texas 76051
Phone 817/410-3556 - Fax 817/410-3038
Date
NOV - S 2013
11/07/2018
CERTIFICATE OF APPROPRIATENESS APPLICATION ft 1c,
Number GA 1 g- 12� NOV ? 2018
Property Owner Name, Address & Phone Number
Dat or Becky Nguyen
924 E Worth St
Grapevine, TX 76051
Phone:
Mobile:9727466668
Email:
Property Address include any suite number
T Z `i
Ten nt Name/Occupancy/Use • E: 156 x Fpu 5 F
Residence
Request/Description of Work to Be Done
A plicant Name, Address & Phone Number
Structured Foundation Repairs Inc - Patricia Palos
13301 Trinity Blvd #133
Euless. TX 76040
Phone:9724841200
Mobile
Email:
Leaal Descriotion
Block 9 Lot 3R
Subdivision D E ADDITION BOX
install concrete pilings adjust existing pilings and reset/reshim understructure to stabilize foundation
Drawings/Sketches Attached Photo ra hs Attached
x Yes o No o Current o Historic
Material Sample(s) Attached (please list)
I hereby certify that this information is correct to the best of my knowledge and that the said work will be done in conformance
with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and
Building Codes. APPROVAL OFA CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF
OTHER REQUIRED BUILDING PERMITS.
Signed j x
Owner or Contractor
Print Narne7 Patricia Palos
Office Use
Approve Approved with Conditions:
Staff r
HPC ��2rY1 I f � u f r2r�J
o Denied
Chair— Historic Preservation Commission
Building Official
istoric Pregervation Ofricet
Date ��>\. I2 . ;,018
THIS IS NOT A BUILDING PERMIT.
A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY
THE BUILDING DEPARTMENT BEFORE STARTING WORK.
DELIVER TO: HISTORIC PRESERVATION DEPARTMENT OFFICE 817-410-3556
636 SOUTH MAIN STREET, GRAPEVINE, TEXAS
0<:�A 1:9 z
Adam A. Green, P.E. (FL & TX), MBA
CROSSTOWNTampa: (813) 702 -3398 1 Dallas/Ft. North (469) 751-7694
i-,i-1N,cv. Cros stocc,iiEngineeiuie.com
Date: November 5, 2018
Attention: Structured Foundation Repairs, Inc. (via e-mailT
Subject: Structural Foundation Initial Inspection Report
924 E Worth St, Grapevine, TX 76051
To Whom It May Concern:
Crosstown Engineering (CE) was retained to conduct a review of the provided pier plan prepared by Struc-
tured Foundation Repairs, Inc. (SFR) to determine if it is a reasonable limited plan of repair.
CE visited the subject site to interview the property owner, observe the structure and terrain, and to verify
the floor elevation data.
We observed drywall cracks that indicated settlement was occurring on the front -left and right -left sides of
the structure. These observations are confirmed by floor elevation data.
SFR has proposed to perform the following in the approximate locations of the structure as indicated on the
limited repair plan to support the foundation:
• Install 6 exterior pilings.
• Adjust 26 existing pilings.
• Reset/re-shim in localized area.
Based on our observations, it is our opinion that the proposed plan of repair is reasonable. Additional repairs
may be needed in the future as the foundation continues to move seasonally. Because the structure has
endured pre -repair foundation differential movement, residual differential elevation and perceptible floor
slope may remain following the limited foundation repairs. It appears that the soils are very active, and the
building is susceptible to seasonal movement. We recommend monitoring the foundation over time. This
limited repair plan is intended to provide a reasonable repair to improve the performance of the foundation
and is not intended to level the foundation. The contractor shall determine the amount of elevation correc-
tion needed based on the reaction of the structure during the lift in order to minimize damages and additional
stress.
Please see the Disclosure & Disclaimer, pier detail (if provided), and limited repair plan for more infor-
mation and do not hesitate to call us if you have any questions.
Sincerely,
Crosstown Land Development Services
Texas Engineering Firm (F-15944)
Adam Green, P.E.
Professional Engineer (TX #116597)
1:.✓,. ` fr'/t.�.................... EN ...GRE
ADAM A. ..
,,��
11/5/18
Foundation Report
Page 1 of 4
Adam A. Green, P.E. (FL & TX), MBA
CROSSTOWNTampa: (813) 702 -3398 1 Dallas/Ft. `Worth (469) 751-7694
�rcc�v. Crossto�rliEngineerui�.com
DISCLOSURE & DISCLAIMER
It is known to knowledgeable professional engineers that the soils in this area are subject to movement due to expan-
sion, contraction or densification of the soils etc. This soil movement could possibly cause the foundation to move
after the remediation plan within the attached report has been implemented and may impact the stability of the foun-
dation and cause damage.
NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THIS
FOUNDATION OR THE REPAIRS THERETO. Diligent foundation maintenance to maintain consistent soil condi-
tions along the perimeter should reduce further problems after the recommendations within this report have been
implemented. However, seasonal moisture variations, water leaks, erosion and other factors may affect the stability
of the foundation and put it in danger of further damage.
REPORT LIMITATIONS
This report is written for informational purposes only and is not intended to be a detailed technical evaluation of the
property or an inventory of defects. The opinions expressed in this report are based on a visual evaluation of current
conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CON-
CERNING THIS ENGINEERING REPORT.
The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land De-
velopment Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or
owners will be responsible for:
1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and
testing of the recovered samples,
2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and
3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily
available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions.
Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance
of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly
noted is specifically excluded.
The provided Floor Elevation Map and resulting recommendations are based on conditions as they now exist and
DOES NOT IMPLY OR WARRANT THAT OTHER PROBLEMS AND OR AREAS MAY NOT MANIFEST IN
THE FUTURE.
This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission
for use by any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in
writing by CE.
CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSIONS BY THE CONTRACTOR OR HIS SUBCON-
TRACTORS PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PER-
FORM THE WORK IN ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAU-
TIONS INCIDENTAL THERETO.
CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client ex-
pressly disclaims that it has contracted for or received any warranty of fitness for a particular purpose with respect to
this report. THE REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WAR-
RANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT.
Foundation Report
Page 2 of 4
PRESSED PILING SPECIFICATIONS
SIDE VIEW FRONT VIEW
EXISTING -
STRUCTURE
►� ��
OI OI ♦ - �•��Iw
�'I OI Oi �IpIA�I
CONCRETE� � OIC OI • -
CONCRETE
CAP
CYLINDERS. 12',18'
OR 24" SECTIONS
MAY BE USED.
924 E WORTH ST, GRAPEVINE, TX 76051
CROSSTOWN
12"LENGTH
6" DIAMETER
AND/OR
8" LENGTH
4" DIAMETER
PILE SECTIONS
OFT
11
ADAM A. GREEN
/ ......
............
116597 ;
11.5.18
CROSSTOWN ENGINEERING
TBPE FIRM F-15944 - WWW CROSSTOWN ENG INEERING. COM
(469) 751-7694 - DALLAS METROPLEX
j
TENSILE STRENGTH
w
>
PROVIDED BY TWO
x
COLUMNS OF #3 OR
w
#4 SCHEDULE 60
m
REBAR EPDXY OR
GROUT IN PLACE.
x'l)
In:)
LL
mw
Ofr
z0
J F
d
O
w
REBAR SHALL
PREVENT LATERAL
Lu
x
DISCONNECT
a
BETWEEN
CYLINDERS. 12',18'
OR 24" SECTIONS
MAY BE USED.
924 E WORTH ST, GRAPEVINE, TX 76051
CROSSTOWN
12"LENGTH
6" DIAMETER
AND/OR
8" LENGTH
4" DIAMETER
PILE SECTIONS
OFT
11
ADAM A. GREEN
/ ......
............
116597 ;
11.5.18
CROSSTOWN ENGINEERING
TBPE FIRM F-15944 - WWW CROSSTOWN ENG INEERING. COM
(469) 751-7694 - DALLAS METROPLEX
J+ C�A 1oo -12
CONSTRUCTION NOTE: IF INTERIOR PILING LOCATIONS ARE SHOWN ON THIS MAP
THEY ARE APPROXIMATED AND ARE LOCATED WITHOUT KNOWLEDGE OF THE
LOCATIONS OF THE INTERIOR GRADE BEAMS. THE CONTRACTOR SHALL MAKE FIELD X -4.2
'U Df -MENS"AgVAMBE
NS AND OBSERVED
SLA UA EMlffCAT
IONS. FINALSCO C ORD. x
PLEASE NOTE: IF EXISTING PILINGS ARE SHOWN ON THIS MAP, THEIR LOCATION
WAS PROVI EE:• --CE DOES NOT CERTIFY THEIR
PERFORMA I E � LIKE TO DETERMINE IF THEY -4.8 GARAGE
ARE ACTUA P E M TH WNER OR CONTRACTOR TO
OBTAIN AN- G I C IF E' 0 THEM.''
CERTIFICATE OF APPROPRIATENESS
CITY OF GPjaPc: nNic
PURsuA; � ,
r-�Z7v X
DATE r� iz
D, AR MENT OF -3.5
DEVELOPMENT SERVICES
1 2 1A 24
CONTACT BUILDING INSPECTIONS -3.3 -2.9
-1.0 -1.8 FOR PERMIT INFORMATION
-2.7 is
3A
6 4A 5A
-2.2
-2.3 -2.6
5 -1.2
4 -2.7 9A -1.9 -2.2 -2.2
RESET/RE-SHIM -1.64D
8A 7A 6A
AN
AS NEEDED -2.9
3 -2.2 -1.5 -1.4 0.0
22A
-2.4 -2.7 0.4
-0.6 -0.6
21A 23A 24A
20A FP
-2.2 -2.6
19A 26A 25A -1.3
-2.6 -1.6
-5.8
X
-3.3
x
x
-3.4
X
-0.3
-0.9
ISLAND
F -A FP 0.2
0.2 0.8 0.2
-2.4 -2.0
-1.1 -0.6
18A 17A 16A -1.7 -0.7 -0.7 -0.4
Aft
INSTALL 6 EXTERIOR PILINGS, 15A 13A 11A
ADJUST 26 EXISTING PILINGS, FRONT
RESET/RE-SHIM IN LOCALIZED AREA. 14A 12A 10A
LIMITED REPAIR PLAN 'NOT TO SCALE - ALL LOCATIONS APPROXIMATE'
PRE -LIFT ELEVATIONS BYCE (11.2.18) 0.0 POST -LIFT ELEVATIONS BY CE (
LEGEND
0.2
"N't
0.8
A ELEVATION BASEPOINT PROPOSED PAD/BLOCK X EXISTING PIER 7It
o, 116597 :',,�
1-A -.. O:'�:
PROPOSED BEAM ■ EXISTING PAD/BLOCK O PROPOSED BREAKOUT 11.5.18 IIC�' 4!CENS'9 -X%
IMFSS/ONA�'NG
EXISTING BEAM PROPOSED PIER ® EXISTING BREAKOUT
x� CROSSTOWN ENGINEERING
t
ROSSTOWN TBPE FIRM F-15944 - WWW.CROSSTOWNENGINEERIN G.COM
(469)-751-7694 - DALLAS METROPLEX
ENGINEERING I FOUNDATION REPAIR
924 E WORTH ST, GRAPEVINE, TX 76051