HomeMy WebLinkAboutTerracon - 11/26/2018 (3)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0549 Service Date: 11/15/18 2501 E Loop 820 N Report Date: 11/26/18 Revision 1 - 2 -day results Fort Worth, TX 76118-6978 Task: Parkine Garace 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 0700 Plant: 123 Truck No.: 5112 Ticket No.: 12334065 Field Test Data Test Result Specification Slump (in): 8 5-9 Air Content (%): 4.6 3-6 Concrete Temp. (F): 56 Ambient Temp. (F): 38 Plastic Unit Wt. (pcf): 144.8 Yield (Cu. Yds.): Sample Date: 11/15/18 Sample Time: 0817 Sampled By: Christopher Thompson Weather Conditions: Clear Accumulative Yards: 18/324 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Grid Line, P1/15.1 Placement Location: Garage Level 6, Pour 2, Grild Line (psi) P1 -P5/15-18 Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 1 A 4.00 12.57 11/16/18 11/17/18 2 55,440 4,410 5 1 B 4.00 12.57 11/16/18 11/21/18 6 71,770 5,710 4 1 C 4.00 12.57 11/16/18 12/13/18 28 1 D 4.00 12.57 11/16/18 12/13/18 28 1 E 4.00 12.57 11/16/18 12/13/18 28 1 F 11/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher Thompson Reported To: Contractor: Manhattan Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0549 Service Date: 11/15/18 2501 E Loop 820 N Report Date: 11/26/18 Revision 1 - 2 -day results Fort Worth, TX 76118-6978 Task: Parkine Garace 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 1035 Plant: 123 Truck No.: 5114 Ticket No.: 12334087 Field Test Data Test Result Specification Slump (in): 9 5-9 Air Content (%): 6.0 3-6 Concrete Temp. (F): 58 Ambient Temp. (F): 56 Plastic Unit Wt. (pcf): 141.6 Yield (Cu. Yds.): Sample Date: 11/15/18 Sample Time: 1058 Sampled By: Christopher Thompson Weather Conditions: Clear Accumulative Yards: 117/324 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Grid Line, P3.7/16.3 Placement Location: Garage Level 6, Pour 2, Grild Line (psi) P1 -P5/15-18 Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 2 A 4.00 12.57 11/16/18 11/17/18 2 45,210 3,600 2 2 B 4.00 12.57 11/16/18 11/21/18 6 60,690 4,830 5 2 C 4.00 12.57 11/16/18 12/13/18 28 2 D 4.00 12.57 11/16/18 12/13/18 28 2 E 4.00 12.57 11/16/18 12/13/18 28 2 F 11/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher Thompson Reported To: Contractor: Manhattan Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0549 Service Date: 11/15/18 2501 E Loop 820 N Report Date: 11/26/18 Revision 1 - 2 -day results Fort Worth, TX 76118-6978 Task: Parkine Garace 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 1230 Plant: 123 Truck No.: 1737 Ticket No.: 12334108 Field Test Data Test Result Specification Slump (in): 9 5-9 Air Content (%): 6.0 3-6 Concrete Temp. (F): 63 Ambient Temp. (F): 64 Plastic Unit Wt. (pcf): 141.6 Yield (Cu. Yds.): Sample Date: 11/15/18 Sample Time: 1320 Sampled By: Christopher Thompson Weather Conditions: Clear Accumulative Yards: 216/324 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Grid Line, P2.9/17.5 Placement Location: Garage Level 6, Pour 2, Grild Line (psi) P1 -P5/15-18 Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 3 A 4.00 12.57 11/16/18 11/17/18 2 50,830 4,040 3 3 B 4.00 12.57 11/16/18 11/21/18 6 75,040 5,970 2 3 C 4.00 12.57 11/16/18 12/13/18 28 3 D 4.00 12.57 11/16/18 12/13/18 28 3 E 4.00 12.57 11/16/18 12/13/18 28 3 F 11/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher Thompson Reported To: Contractor: Manhattan Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0549 Service Date: 11/15/18 2501 E Loop 820 N Report Date: 11/26/18 Revision 1 - 2 -day results Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 1628 Plant: 123 Truck No.: 9008 Ticket No.: 12334134 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Result Specification 9 5-9 6.0 3-6 60 63 142.0 Set Specimen Avg Diam. Area Date No. ID (in) (sq in) Received 4 A 4.00 12.57 11/16/18 4 B 4.00 12.57 11/16/18 Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 11/15/18 Sample Time: 1656 Christopher Thompson Clear 315/324 Batch Size (cy): 9 Pump 0 0 Grid Line, P4/17.9 Garage Level 6, Pour 2, Grild Line P1 -P5/15-18 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/17/18 2 43,190 3,440 11/21/18 6 69,590 5,540 4 C 4.00 12.57 11/16/18 12/13/18 28 4 D 4.00 12.57 11/16/18 12/13/18 28 4 E 4.00 12.57 11/16/18 12/13/18 28 4 F 11/16/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Fracture Tested Type By 5 3 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher Thompson Reported To: Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cx000t, 11-16-12, xev.6 Page 4 of 4 Distribution Page Irerracon Report Number: 95181011.0549 Service Date: 11/15/18 2501 E Loop 820 N Report Date: 11/26/18 Revision 1 - 2 -day results Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva