Loading...
HomeMy WebLinkAboutTerracon - 11/28/2018 (8)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0552 Service Date: 11/16/18 2501 E Loop 820 N Report Date: 11/28/18 Fort Worth, TX 76118-6978 Task: Hotel 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 7,000 psi @ 28 days Mix ID: 9908 Supplier: ARGOS Batch Time: 1116 Plant: 111 Truck No.: 1033 Ticket No.: 11121490 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 8 6-9 2.9 0-3 74 50-104 65 4.00 150.5 0 Laboratory Test Data Set Specimen Avg Diam. No. ID (in) 1 A 4.00 1 B 4.00 1 C 4.00 1 D 4.00 1 E 0 Initial Cure: Outside 0 Comments: Sample Date: 11/16/18 Sample Time: 1220 Sampled By: Kristopher McGarry Weather Conditions: Clear, low wind Accumulative Yards: 9/27 Batch Size (cy): 9 Placement Method: Bucket & lift Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Column for hotel between level 1 & 2 12.57 @ E.2/10 Placement Location: Columns between levels 1 & 2 @ 12.57 E.2/10, E.8/10, E.2/9, E.8/9, G.6/9, 28 C.6/8 Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 12.57 11/23/18 7 86,220 12.57 12/14/18 28 12.57 12/14/18 28 12.57 12/14/18 28 Hold Final Cure: Moist Room Compressive Strength Fracture Tested (psi) Type By 6,860 3 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Kristopher McGarry Reported To: David Saiter w/ Manhattan Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Paae Report Number: 95181011.0552 Service Date: 11/16/18 Report Date: 11/28/18 Task: Hotel Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600